OPERATING MANUAL
MHPH - 195/295/330/880
FOR QUICK REFERENCE, RECORD YOUR MACHINE DATE HERE:
Model _________________________ Serial #_____________________ Volts______________________
Phase __________________________ HP ______________________ Date Shipped ______________
SPECIFICATIONS
MHPH - 195 ....................................................................................................................................3
MHPH - 295 ....................................................................................................................................4
MHPH - 330 ....................................................................................................................................5
MHPH - 880 ....................................................................................................................................6
INTRODUCTION.................................................................................................................................7
INSTALLATION INSTRUCTIONS
GAS SUPPLY...................................................................................................................................8
VENTING REQUIREMENTS..........................................................................................................9
BASIC CONTROLS.........................................................................................................................10
OPERATING INSTRUCTIONS
PILOT IGNITION...........................................................................................................................10
BURNER OPERATION..................................................................................................................10
BURNER MAINTENANCE............................................................................................................10
GENERAL MAINTENANCE & CARE...........................................................................................11
TROUBLE SHOOTING GUIDE.............................................................................................................12-13
DIAGRAMS
ELECTRICAL WIRING DIAGRAM.............................................................................................14
TABLE OF CONTENTS
2
SPECIFICATIONS
MHPH - 195
INSTANTANEOUS WATER HEATER.................................Propane or Nat. Gas Fired
HEATING COIL....................................................................98 Ft. Schedule 40
BURST PRESSURE...............................................................10,380 PSI
HYDROSTATIC TEST..........................................................4,000 PSI
WORKING PRESSURE.........................................................2,000 PSI
BURNER................................................................................Impinged Jet Type Atmospheric Draft
ORIFICE JETS.......................................................................Propane: No 68 Drill
Nat. Gas: No 55 Drill
IGNITION..............................................................................Standing Pilot
Standard Piezo Spark Pilot Igniter
INPUT.................................................................................... Propane: 195,000 BTU
Nat. Gas: 185,000 BTU
ALTITUDE RATING..............................................................0 To 4500 Ft. With No Orifice Change
MANIFOLD PRESSURE........................................................Propane: 11 In. W.C.
Nat. Gas: 3.5 In W.C.
TEMPERATURE RISE...........................................................100 F at 192 GPH
FLUE OUTLET.......................................................................7 In. Diameter
C O EMISSIONS.....................................................................Less than 50 PPM
AUTOMATIC GAS VALVE...................................................Combination Type: Millivolt Operated
HIGH LIMIT SWITCH............................................................Protects Against Overheating
Set at 210 F (Hot Water) or
340 F (Steam)
PRESSURE SWITCH..............................................................Prevents Burner Operation
Without Water Flow
TOGGLE SWITCH..................................................................Provides Manual “On-Off” Control
SAFETY RELIEF VALVE.......................................................Set at 2000 PSI
3
SPECIFICATIONS
MHPH - 295
INSTANTANEOUS WATER HEATER.................................Propane or Nat. Gas Fired
HEATING COIL....................................................................165 Ft. Schedule 40
BURST PRESSURE...............................................................10,380 PSI
HYDROSTATIC TEST..........................................................4,400 PSI
WORKING PRESSURE.........................................................2,200 PSI
BURNER................................................................................Impinged Jet Type Atmospheric Draft
ORIFICE JETS.......................................................................Propane: No 67 Drill
Nat. Gas: No 54 Drill
IGNITION..............................................................................Standing Pilot
Standard Piezo Spark Pilot Igniter
INPUT.................................................................................... 290,000 BTU
ALTITUDE RATING..............................................................0 To 4500 Ft. With No Orifice Change
MANIFOLD PRESSURE.........................................................Propane: 11 In. W.C.
Nat. Gas: 3.4 In W.C.
TEMPERATURE RISE...........................................................100 F at 288 GPH
FLUE OUTLET.......................................................................9 In. Diameter
C O EMISSIONS.....................................................................85 ppm (.0085%)
AUTOMATIC GAS VALVE...................................................Combination Type: Millivolt Operated
HIGH LIMIT SWITCH............................................................Protects Against Overheating Set at
210 F (Hot Water) or 340 F (Steam)
PRESSURE SWITCH...............................................................Prevents Burner Operation
Without Water Flow
TOGGLE SWITCH..................................................................Provides Manual “On-Off” Control
SAFETY RELIEF VALVE.......................................................Set at 2200 PSI
4
SPECIFICATIONS
MHPH - 330
INSTANTANEOUS WATER HEATER.................................Propane or Nat. Gas Fired
HEATING COIL....................................................................196 Ft. Schedule 80
BURST PRESSURE...............................................................14,000 PSI
HYDROSTATIC TEST..........................................................6,000 PSI
WORKING PRESSURE.........................................................3,000 PSI
BURNER................................................................................Impinged Jet Type Atmospheric Draft
ORIFICE JETS.......................................................................Propane: No 65 Drill
Nat. Gas No 53 Drill
IGNITION..............................................................................Standing Pilot
Standard Piezo Spark Pilot Igniter
INPUT.................................................................................... 330,000 BTU
ALTITUDE RATING..............................................................0 To 4500 Ft. With No Orifice Change
MANIFOLD PRESSURE.........................................................Propane: 11 In. W.C.
Nat. Gas: 3.5 In. W.C.
TEMPERATURE RISE..........................................................100 F at 345 GPH
FLUE OUTLET......................................................................9 In. Diameter
C O EMISSIONS....................................................................120 ppm (.012%)
AUTOMATIC GAS VALVE..................................................Combination Type: Millivolt Operated
HIGH LIMIT SWITCH...........................................................Protects Against Overheating Set at
210 F (Hot Water) or 340 F (Steam)
PRESSURE SWITCH.............................................................Prevents Burner Operation
Without Water Flow
TOGGLE SWITCH.................................................................Provides Manual “On-Off” Control
SAFETY RELIEF VALVE......................................................Set at 3000 PSI
5