East EA900Pro Series, EA902P, EA901P, EA903P Operation Manual

Table of Contents
1 Safety Information ........................................................................... 2
1.1 UPS
SAFETY INFORMATION ........................................................... 2
ATTERY SAFETY INFORMATION .................................................... 2
2 Product Overview ............................................................................ 4
2.2 F
2.3 R
PECIFICATIONS ........................................................................... 4
RONT PANEL FEATURES .............................................................. 6
EAR PANEL FEATURES ................................................................ 6
3 Installation ........................................................................................ 7
3.1 U
3.2 I
3.3 I
NPACKING INSPECTION ............................................................... 7
NSTALLATION INFORMATION ......................................................... 7
NSTALLATION AND OUTPUT CONNECTION ...................................... 8
XTERNAL BATTERIES CONNECTION (LONG BACKUP MODEL) .......... 8
4 Network Functions ......................................................................... 10
4.1 C
4.2 EPO
4.3 I
OMMUNICATION PORT ............................................................... 10
PORTOPTIONAL) ........................................................... 10
NTELLIGENT CARD (OPTIONAL).................................................... 11
5 Operation ........................................................................................ 12
5.2 D
5.3 UPS
5.4 UPS
5.6 O
UTTON OPERATION ................................................................... 12
ISPLAY INTERFACE .................................................................... 13
ON/OFF OPERATION ........................................................... 14
SETTINGS ........................................................................... 15
ARAMETERS INQUIRING OPERATION ........................................... 17
PERATION MODE....................................................................... 18
6 Fault Messages and Alarm ........................................................... 20
7 Troubleshooting ............................................................................. 25
1
1 Safety Information
1.1 UPS safety information
Read all safety information an d operat ing instru ction s caref ully before atte mpting t o
install, service or maintain the UPS. Save this manual properly for reuse.
This UPS is intended for indoor use only. Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space against
the wall for proper ventilation.
Do not open the UPS case as you will, there is a high risk of electric shocks inside.
All connection/wiring/s ervicing must be performed by a qualified electrician.
Do not connect to the equipment like hair dryer or electric heater. Do not use liquid extinguisher if there is a fire, a dry powder extinguisher is
recommended.
CAUTION
UPS has high voltage inside, do not repair it by yourself. If any questions, please contact local service center or dealer.
1.2 Battery safety information
Environmental factors impact battery life. Elevated ambient temperatures, poor
quality utility power, and frequent short duration discharges will shorten battery life. Replacing battery periodically can help to keep UPS in normal state and assure backup time required.
Battery instal ling or replacing should be performed by a qualified electrician. If you
want to replace the battery cable, please purchase it from our local service center or distributors to avoid fever and lighter which can cause fire by inadequate power capacity.
Batteries may cause electric shocks and have a high short ci rcuit current, follow
below requirements before installing or replacing the batteries. A. Remove wristwatches, rings, jewelry and other conductive materials. B. Only use tools with insulated grips and handles C. Wear insulated shoes and gloves
2
D. Do not put the metal tools or parts on the batteries
E. Before disconnecting the terminals from the batteries, cut off all the loads to the
battery first.
Do not dispose of the batteries with fire. The batt er ie s may explode. Do not open or mutilate batteries. Released electrolyte inside is harmful to the skin
and eyes, and maybe toxic.
Do not connect the positive pole and negative pole directly, otherwise it will cause
electric shocks or wil l be on fire.
The battery circuit is not isolated from the input voltage, high voltage may occur
between the battery terminals and ground, check if there is no voltage there before touching.
Symbols
Symbol Significations Symbol Significations
Caution
Danger! High Voltage!
Turn on
Turn off
Standby or Shut down
AC
DC
Protective earth
Disable/mute audible
alarm
Overload
Battery inspection
Repeat
Display screen repeat key
Battery
3
frequency
Total voltage harmonic
2 Product Overview
2.1 Specifications
Model 1kVAS 1kVAH 2kVAS 2kVAH
Rated Capacity 1 kVA / 900 W 2 kVA / 1800 W 3 kVA / 2700 W
Input
Rated input voltage 208 Vac / 220 Vac / 230 Vac / 240 Vac Rated input frequency 50 Hz / 60 Hz (auto-sense)
Input voltage range
Input frequency range 40 ~ 70 Hz PFC 0.99 THDI 6% Bypass voltage range -25% ~ + 15% (settable)
Output
Output voltage 208 Vac / 220 Vac / 230 Vac / 240 Vac (settable) Voltage accuracy ± 1% Output PF 0.9
Inverter overload capability
Load crest 3:1 From mains mode to BAT mode From mains mode to bypass
Line mode
Efficiency
Output
BAT mode 85% 86% 87% ECO mode 95% 96% 97% Line mode Same as input frequency BAT mode (50 / 60 ± 0.1) Hz
110 ~ 176 Va c (power derating linearly between 50% and 100% load);
176 ~ 280 Vac (no derating); 280 ~ 300Vac (power derating 50%)
105% ~ 125% load: transfer to bypass in 1 min;
125% ~ 150% load: transf er to bypass in 30 s;
> 150% load: transfer to bypass in 300 ms ;
0 ms (trans fe r time)
4 ms
90% 91% 92%
3kVAS 3kVAH
distortion
2% (linear load); 5% (non-linear load )
4
12 V
12 V
12 V
12 V
12 V
12 V
2 3 3 4 6 6 6 8 8
± 0.4
± 0.6
± 0.6
± 0.8
± 1.2
± 1.2
± 1.2
± 1.6
± 1.6
Overload protection; Output sh ort
Batteries
Battery type Sealed lead acid maintenance free battery DC voltage
Inbuilt battery
Quantity
Charger output voltage
Recharging time Recover 90% capacit y i n 3 hours for standard models
24 V 36 V 36 V 48 V 72 V 72 V 72 V 96 V 96 V 9 AH
27.1
7 AH
40.7
/
40.7
9 AH
54.2
7 AH
81.3
/
81.3
9 AH
81.3
7 AH
108.4
/
108.4
Charging current (Max.)
Standard model: 1 A
Long time model: 6 A / 3 A
System Control and Communications
Protections
Over-temp protection; Fan testing protection;
circuit protection; Battery discharge protection Communication port Standard: RS232; Options: USB, SNMP card, dry contacts Display LCD
Environmental
Operating humidity 0 ~ 90 % RH @ 0 ~ 40°C (non-condensing) Storage temperature -25°C ~ 55°C(exclude batteries) Operating altitude 1000m, above 1000m, der ate 1% for each rising 100m Protection class IP 20 Noise level 50 dBA (at 1m)
Others
Dimensions (mm) W ×D×H Weight (kg)
144*336
144*414
144*336
191*418
191*418
191*418
191*418
191*464
*214
*214
*214
*335
*335
*335
*335
*335
9.5 13 6 18 25.8 10.5 27.2 32 11
191*418
*335
* Derate capacity to 70% in CUCF mode and to 90% when the output voltage is adjusted to 208Vac.
Note:
Model Type Model Type
1kVAS 1kVA Standard model 1kVAH 1kVA Long backup model 2kVAS 2kVA Standard model 2kVAH 2kVA Long backup model 3kVAS 3kVA Standard model 3kVAH 3kVA Long backup model
5
2.2 Front panel features
2.3 Rear panel features
a. 1kVAS & 1kVAH rear panel b. 2kVAS &2kVAH & 3kVAS & 3kVAH rear panel
① AC input socket ⑥ RS232 port ② Overcurrent protector ⑦ Intelligent slot ③ Fan ⑧ Surge protection for network / fax / modem ④ USB port Output sockets ⑤ EPO (Emergency Power Off) port Battery connector
Note: The figure is for reference only. Due to the technology upgrading and development, the real unit might be different from the figure.
6
~ 4
3 Installation
3.1 Unpacking inspection
Open the UPS package and inspect the contents upon receipt. The accessories
attached to the UPS contain a power cord, a user manual , communication c able, CD-ROM. The long backup model also includes the cable for connection to battery bank.
Check if the unit is damaged during transport. Do not power on and notify the
carrier and dealer if find damaged or parts missing.
Verify this unit is the model you want to buy. Check the model name showed both
on the front panel and rear panel.
Note:
Keep the packaging box and packaging materials for future transport use. The equipment is heavy. Always handle it with care.
3.2 Installation information
The UPS installation environment must be in good ventilation, away from water,
flammable gases and corrosive entities.
Do not lie down the UPS agai nst the w all so tha t front an d sid e pane l air int ake h ole,
rear panel air outtake hole will be unobs tructed.
The ambient temperature around the UPS should be within 0
non-condensing.
If dismantling the machine at low temperatures, there may be condensation
droplets, users can not install or operate it before UPS completely got dry both inside and outside, otherwise there will be danger of electric shocks.
Place the UPS near the mains source so that can cut off utility power without any
delay in case of emergency.
Make sure the load connected to the UPS is off when users connect it to UPS, and
then turn on the load one by one later.
Connect the UPS with the power outlet which is over-current protected. Do not
connect the UPS with power outlets whose rated current is less than the maximum input current of this UPS.
All power outlets should be configured with earthing device for safety. UPS could be electrified or powered no matter the input power co rd is tied or not,
even when the UPS is off. The only way to cut off the output is switching off the UPS and disconnecting the mains power supply.
7
Neutral
For all standard model UPS, it is advised to charge the batteries over 8 hours
before using. Once the AC mains power energizes the UPS, it will automatically charge the batteries. Without prior charging, UPS output remains as usual but with shorter back-up time than normal.
When connected to motor, display equipment, laser printer etc, UPS power
selection should be based on the startup power of the load which is usually twice as rated power.
Wiring by a qualified electrician is required. Ensure input cables and output cables
are connected correctly and firmly.
If install a leakage current protective switch, please install it on output cable. For 1-3K series long backup model units, you may need to prepare wires for
terminals based on the following table.
Wiring sp ec (AWG)
Model
Input Output Battery
1kVAS_DC24V 1mm² 1mm² 6mm² 1mm² 1mm² 1kVAS_DC36V 1mm² 1mm² 4mm² 1mm² 1mm² 1kVAH_DC36V 1mm² 1mm² 4mm² 1mm² 1mm² 2kVAS_DC48V 1.5mm² 1.5mm² 6mm² 1.5mm² 1.5mm² 2kVAS_DC72V 1.5mm² 1.5mm² 4mm² 1.5mm² 1.5mm² 2kVAH_DC72V 1.5mm² 1.5mm² 4mm² 1.5mm² 1.5mm² 3kVAS_DC72V 2.5mm² 2.5mm² 6mm² 2.5mm² 1.5mm² 3kVAS_DC96V 2.5mm² 2.5mm² 4mm² 2.5mm² 1.5mm² 3kVAH_DC96V 2.5mm² 2.5mm² 4mm² 2.5mm² 1.5mm²
Non-isolated
Ground
3.3 Installation and output connection
Normally, output connection of 1~3kVA series is configured with power outlets or terminal blocks, users can plug the load cable into the UPS power outlets to energize the load. Make sure the mains cable and breakers in the building are enough for the rated capacity of UPS to avoid the hazards of electric shock or fire.
3.4 External batteries connection (long backup model)
For different UPS model, users are instructed to configure different battery voltage
as below table. More or less units are forbidden, or else something abnormal or faulty will appear.
8