Installation Instructions
Overhead Door Closer – Model DCS2024/25
Architectural Hardware Ltd
Eurospec
Stancliffe Street, Mill HIll
Blackburn, BB2 2QR
21 - CPD - AD0198
21 - CPD - AD0199
IMPORTANT INFORMATION
Selecting the correct door closer to suit door size
Power Size Max. Width of Door Max. Mass of Door
2 850mm 40Kg
3* 950mm 60Kg
4 1100mm 80Kg
5 1250mm 100Kg
6 1400mm 120Kg
*Minimum size for use on fire doors
Important notes:
Minimum size 3 MUST be used on fire doors
Hold open arms must NOT be used on fire doors
This product is non handed and can be fitted on both left handed and right handed doors.
Maintenance
Check that the door closer closes the door correctly and adjust as necessary. Ensure fixing screws are tight and periodically
apply light oil or grease to arm knuckle joint
Tel: +44 (0) 1254 274100
Fax: +44 (0) 1254 274111
Web: www.eurospec.co.uk
PLEASE LEAVE THESE INSTRUCTIONS WITH THE END USER
Copyright © 2008 Eurospec
Failure to install this product as per these instructions &
dimensions shown on template will negate guarantee
Page 1
Door Closer – Model DCS2024/25 Rev.1
Installation – Fig 1 Application – Angle of opening 180°
Fig 1 – Standard Application (Door closer fitted on pull face of door)
Illustrations show anti-clockwise closing door
1. Ensure that the door & surrounding frame are in good
condition & the door closes freely.
2. Select the correct hand of Fig. 1 easi-fit template
and with the door in the closed position, stick template to
top corner of door and frame. (See Figs. 1 & 2)
3. Determine the power size required and using the supplied
allen key, adjust door closer strength as per chart on
template. Drill pilot holes in door and frame according to
template. Remove slide plate and fix door closer body with
screws supplied ensuring power adjusting valve faces away
from hinge side of door. (See Figs. 2 & 3)
4. Carefully detach link arm from adjuster arm & securely fix
adjuster arm shoe to frame ensuring the shoe is rotated
in the correct position as shown on the template. (See Fig. 4)
Note: Rotate shoe 180° for power size 2
n
o
i
t
a
c
i
l
p
p
A
d
r
a
d
n
a
t
S
Fig. 1
Fig. 2
5. Place link arm onto closer spindle at right angles
to door, fit securing screw, move link arm and reconnect to adjuster arm. (See Figs. 4 & 5)
Note: To adjust arm to suit depth of fr ame, loosen
nut, adjust arm & re-tighten nut.
6. Fit spindle cover cap to underside of closer. (See Fig. 5)
7. Check for correct closing & latching speeds and
adjust if necessary. Adjust backcheck as required. (See
Fig.6)
8. Stick easi-exit logo onto indent of slide plate and refit to
door closer. (See Fig. 6)
No.2 Latching Speed
No.1 Closing Speed
Delayed Action
Adjust power strength of door closer here
S
Adjust if
required
5
&
4
,
3
S
E
I
Z
S
Fig. 3
2
E
Z
I
No.2
No.1
Fig. 5
FAST
SLOW
backcheck
_
Fig. 6
+
Note: For delayed action model DCS2025BCDA, adjust valve as required
Copyright © 2008 Eurospec
Failure to install this product as per these instructions &
dimensions shown on template will negate guarantee
Page 2
Fig. 4
Door Closer – Model DCS2024/25 Rev.1