Earthworks M30BX Users Manual

Electronic Calibration Files
Register your new measurement microphone within 30 days of purchase on our website at
earthworksaudio.com/register.
Once your Measurement Microphone has been registered in our database, we will send you your ECF to the valid email address provided in your registration.
Warranty
All Earthworks microphones carry a limited warranty (parts and labor).
Product Registration
To help you get the most out of your Earthworks purchase, please take a moment and register your product with us online at earthworksaudio.com/register.
M30BX
Battery Powered
Measurement Microphone
User’s Guide
Service & Repair
If you have any problems with your Earthworks products, please contact our Service & Repair Department.
Email: returns@earthworksaudio.com Telephone: (603) 654-2433, ext. 119
Printed in USA
MADE IN USA
earthworksaudio.com
July 11, 2018
M30BX
Description
The Earthworks M30BX is an omnidirectional (pressure) microphone designed and calibrated for measurement purposes. It is a pre-polarized condenser microphone directly coupled to a wideband, low output impedance
preamplier. The M30BX requires a single type P28L (Lithium) or equivalent 6V battery as a power source. It features a linear free-eld frequency response from 9 Hz to 30kHz (please see the enclosed individual calibration
chart). It has low handling noise and a uniform polar pat­tern. Its unique circuitry excludes the transconductance of the input FET from the overall gain structure. The sen­sitivity remains very stable when the microphone is sub­jected to variations in ambient temperature. The M30BX meets or exceeds ANSI Type 1 requirements.
Each microphone is delivered with its own calibration chart providing its individually measured open-circuit sensitivity and the frequency response curve. A computer le containing the frequency response data for import­ing directly into measurement software is available from Earthworks, Inc. upon registering your new microphone. A mounting clip, a calibrator adapter, an XLR to RCA adapt­er, and a battery are included with the microphone.
Applications
The Earthworks M30BX is ideally suited for on-location acoustic measurements including loudspeaker design and quality control, sound system setup and trouble­shooting, room acoustics, or any application where an
accurate free-eld measurement microphone is required
and portability is important or a power source is not read­ily available. Many test systems manufacturers, such as
DRA Labs (MLSSA
), Smaart™ and DEQX™, recommend M30BX microphones. The wide linear minimum-phase response and fast, well-damped impulse response make M30BX an excellent microphone for loudspeaker design, especially for time domain measurements.
The M30BX is simple to operate. Make sure the battery (included) is properly installed in the microphone. To open the battery compartment hold the microphone by the up­per body and unscrew the battery cover sleeve (this cover is not removable). The battery is only switched on when
an XLR connector is plugged into the microphone. The
M30BX will not operate from phantom power.
The M30BX will drive either balanced or unbalanced in­puts. An XLR to RCA adapter is enclosed for driving un­balanced inputs of sound cards directly. Please note that the best S/N ratio is achieved using a balanced interface.
Calibration
The microphone is calibrated at the factory at 1 kHz (in­dependent of any frequency weighting). The sensitivity in
mV/Pa is provided on the enclosed calibration chart. If
on-site calibration is required, use the enclosed one-half inch standard calibration adapter.
Specications
Frequency response: 9Hz to 30kHz +1/-3dB
Polar Pattern: Omnidirectional
Sensitivity: 3mV/Pa (Typical) Power Requirements: 6V Battery Type P28 (2CR-1/N, 4LR44 or eq.) Peak Acoustic Input: 140dB SPL Output: XLR-3 Minimum Load: 600Ω between pins 2 & 3
Noise: 20dB, A equivalent
Dimensions L x D: 220 x 23 mm (8.65 x .910 in.)
Weight: 180g (.4lb)
Specications are subject to change without notice.
Pin 1 “Shield”
Pin 3 “-”
XLR Output Connector Assignment of M30BX
Frequency Response of M30BX (typical)
Impulse Response of M30BX (typical)
Pin 2 “+”
NOTE: Earthworks recommends re-calibration every
ve (5) years.
M30BX Open Battery Compartment
Polar Response of M30BX (typical)