M30BX
Battery Powered
Measurement Microphone
User’s Guide
Service & Repair
If you have any problems with your Earthworks
products, please contact our Service & Repair
Department.
Email: returns@earthworksaudio.com
Telephone: (603) 654-2433, ext. 119
Printed in USA
MADE IN USA
earthworksaudio.com
July 11, 2018
M30BX
Description
The Earthworks M30BX is an omnidirectional (pressure)
microphone designed and calibrated for measurement
purposes. It is a pre-polarized condenser microphone
directly coupled to a wideband, low output impedance
preamplier. The M30BX requires a single type P28L
(Lithium) or equivalent 6V battery as a power source. It
features a linear free-eld frequency response from 9 Hz
to 30kHz (please see the enclosed individual calibration
chart). It has low handling noise and a uniform polar pattern. Its unique circuitry excludes the transconductance
of the input FET from the overall gain structure. The sensitivity remains very stable when the microphone is subjected to variations in ambient temperature. The M30BX
meets or exceeds ANSI Type 1 requirements.
Each microphone is delivered with its own calibration
chart providing its individually measured open-circuit
sensitivity and the frequency response curve. A computer
le containing the frequency response data for importing directly into measurement software is available from
Earthworks, Inc. upon registering your new microphone. A
mounting clip, a calibrator adapter, an XLR to RCA adapter, and a battery are included with the microphone.
Applications
The Earthworks M30BX is ideally suited for on-location
acoustic measurements including loudspeaker design
and quality control, sound system setup and troubleshooting, room acoustics, or any application where an
accurate free-eld measurement microphone is required
and portability is important or a power source is not readily available. Many test systems manufacturers, such as
DRA Labs (MLSSA
™
), Smaart™ and DEQX™, recommend
M30BX microphones. The wide linear minimum-phase
response and fast, well-damped impulse response make
M30BX an excellent microphone for loudspeaker design,
especially for time domain measurements.
The M30BX is simple to operate. Make sure the battery
(included) is properly installed in the microphone. To open
the battery compartment hold the microphone by the upper body and unscrew the battery cover sleeve (this cover
is not removable). The battery is only switched on when
an XLR connector is plugged into the microphone. The
M30BX will not operate from phantom power.
The M30BX will drive either balanced or unbalanced inputs. An XLR to RCA adapter is enclosed for driving unbalanced inputs of sound cards directly. Please note that
the best S/N ratio is achieved using a balanced interface.
Calibration
The microphone is calibrated at the factory at 1 kHz (independent of any frequency weighting). The sensitivity in
mV/Pa is provided on the enclosed calibration chart. If
on-site calibration is required, use the enclosed one-half
inch standard calibration adapter.
Specications
Frequency response: 9Hz to 30kHz +1/-3dB
Polar Pattern: Omnidirectional
Sensitivity: 3mV/Pa (Typical)
Power Requirements: 6V Battery Type P28
(2CR-1/N, 4LR44 or eq.)
Peak Acoustic Input: 140dB SPL
Output: XLR-3
Minimum Load: 600Ω between pins 2 & 3
Noise: 20dB, A equivalent
Dimensions L x D: 220 x 23 mm (8.65 x .910 in.)
Weight: 180g (.4lb)
Specications are subject to change without notice.
Pin 1
“Shield”
Pin 3
“-”
XLR Output Connector Assignment of M30BX
Frequency Response of M30BX (typical)
Impulse Response of M30BX (typical)
Pin 2
“+”
NOTE: Earthworks recommends re-calibration every
ve (5) years.
M30BX Open Battery Compartment
Polar Response of M30BX (typical)