Eagle Signal HP5E Catalog Page

EAGLE SIGNAL brand
Electronic Timers
HP5E CYCL-FLEX
®
Reset Timer
Modern, high quality timer housed in industry standard patented plug-in housing
E
The Eagle Signal brand Series HP5E CYCL- FLEX timer is a modern,
L
microprocessor based reset timer housed in the standard CYCL- FLEX
T
E
plug-in enclosure. Timing progress is indicated by a LED array that
I
C
displays remaining time interval. Its 5.20 inches circumference
M
T
E
calibrated dial is easy-to-read with well defined resolution increments on
R
R
all ranges. The 15 terminal ABS (U. L. rated 94V- 0) molded housing
O
S
T
N
has high impact resistance and will not support combustion.
I
I
M
C
16 standard time ranges from 5 seconds to 60 hours
E R
Knob adjustable time ranges and LED progress indicator
S
Pilot light indicates when timer is active
Optional reverse action mode will not reset on power failure
15 terminal ABS (UL rated 94V-0) molded housing has high impact
resistance and will not support combustion
SPECIFICATIONS
Time Ranges
Sym.
Dial
Minimum
Setting
17 15 14
0 1 2 3 4
18
5 6 7 8
9 10 11
Reset Time: 500 mS at maximum setting Voltage/ Frequency:
120 V (+10 -15%) 50/60 Hz 240 V (+10 -15%) 50/60 Hz
Power Consumption: 1.5 watts Contact Rating:
10 Amps Resistive / Inductive @ 120vAC 1/6 HP @ 120VAC 5 Amps Resistive / Inductive @ 240VAC 1/2 HP @ 240VAC Electrical Contact Lifetime: Average, contingent on load characteris-
tics. Inrush current should not exceed 10 amps. At full load: 250,000 cycles
At 1 amp load: 5 million cycles
5 Sec. 10 Sec. 15 Sec. 30 Sec. 60 Sec.
150 Sec.
5 Min. 10 Min. 15 Min. 30 Min. 60 Min.
150 Min.
5 Hr. 10 Hr. 30 Hr. 60 Hr.
1/5 Sec. 1/5 Sec. 1/2 Sec.
1 Sec. 1 Sec. 5 Sec.
12 Sec.
12 Sec
1 Min. 1 Min. 1 Min.
5 Min. 12 Min. 12 Min.
1 Hr. 1 Hr.
Dial
Divisions
1/5 Sec. 1/5 Sec. 1/2 Sec.
1 Sec. 1 Sec.
5 Sec. 12 Sec. 12 Sec.
1 Min.
1 Min.
1 Min.
5 Min. 12 Min. 12 Min.
1Hr.
1 Hr.
Repeat
Accuracy
±.05 Sec. ±.05 Sec. ±.08 Sec. ±1.5 Sec.
±3 Sec.
±7.5 Sec.
±15 Sec.
±2 Sec.
±4.5 Sec.
±9 Sec. ±18 Sec. ±45 Sec.
±1.5 Min.
±3 Min.
±9 Min. ±18 Min.
File No. E61735
C
Power On Response:
28 ms average pull-in 17 ms average drop-out
Operationg Temerature: -10 to +140 F (-23 to +60 C) Approximate weight: 1.7 lbs. Agency Approvals: FM; UL/CUL Recognition
®
US
E61735
FM
APPROVED
OPERATION (reference Schmatic Diagram)
Standard: Instantaneous contacts 9-10-C and 6-7-8 operates directly
with power applied to 1, 11(E) and 2. Different operating sequences are possible depending on the control circuit configuration.
Delayed contacts 4- 3 and 11- A close and contacts 4- 5 and 11- 12 open when timer reaches a timed out condition. Contacts 4- 5 and 11­12 close and contacts 4- 3 and 11- A open when timer is reset.
Reverse Start: Instantaneous contacts 9-10-C and 6-7-8 operates directly with power applied to 1, 11(E) and 2. Different operating sequences are possible depending on the control circuit configuration.
Delayed contacts 4- 3 and 11- A close and contacts 4- 5 and 11- 12 open when timer reaches a timed out position. Contacts 4- 5 and 11- 12 close and contacts 4- 3 and 11- A open when timer is reset.
CRI
12
10
9
C
8
6
7
STANDARD
Factory Wiring
E
A
11
12
3
4
5
Schematic Diagram
CRI
12
10
9
C
8
6
7
REVERSE
Factory Wiring
E
A
11
12
3
4
5
5.06
DANAHER SENSORS & CONTROLS
MOUNTING
3 1/16
(77.77)
3 13/16 (96.83)
4 1/4
(107.95)
4 1/8
(104.78)
DRILL AND TAP FOUR HOLES FOR 8-32 SCREWS (INCLUDED WITH UNIT)
1 13/32 (35.71)
1 13/32 (35.71)
3 3/16 ± 1/16 (80.95 ± 1.57) DIA CUTOUT
1 13/32 (35.71)
5 3/4
(146.05)
1 13/32 (35.71)
TERMINALS AND
WIRING DIAGRAM
ON REAR OF
TIMER CASE
1 5/8
(41.27)
4.250 (107.95)
MTG HOLE USED FOR GROUNDING CASE
C
9
10
MINIMUM SPACING
4.00 (101.60)
6
7
8
11
12
4.875 (123.83)
ENCLOSURES
Model No. NEMA Class Description HN308 1 Surface Mtg. with terminal block HN364 1 Surface Mtg. without terminal block
5
B
4
E
A
3
2
1
ACCESSORIES
Model No. Description
H-5331 Mounting Brackets (2 required per timer) HP50-31 One Hole Mounting Ring HP50-133 Surface Mounting Adapter to use in place of brackets HP50-295E Dial Lock
ORDERING INFORMATION
TIME RANGE
Symbol Description
17 15 14
0 1 2 3 4
0-5 Sec. 0-10 Sec. 0-15 Sec. 0-30 Sec. 0-60 Sec.
0-150 Sec.
0-5 Min. 0-10 Min.
DANAHER INDUSTRIAL CONTROLS
2100 West Broad Street Elizabethtown, NC 28837
Symbol Description
18
5 6 7 8
9 10 11
HP5E 15 A6 01
0-15 Min. 0-30 Min. 0-60 Min.
0-150 Min.
0-5 Hr. 0-10 Hr. 0-30 Hr. 0-60 Hr.
CUSTOMER CARE
Toll-Free: +1.800.390.6405 Fax: +1.910.879.5486 Email: etn-customerservice@dancon.com
VOLTAGE & FREQUENCY
Symbol Description
120V, 50/60 Hz
A6
240V, 50/60 Hz
B6
FEATURES
Symbol
Reverse
01
Dial Lock
07*
Water Resistant Window & Housing
22
*Dial Lock not available with water resistant housing
Description
TECHNICAL SUPPORT
Toll-Free: +1.800.234.8731 Fax: +1.847.782.5277 Email: eagle-signal.techsupport@dancon.com