EAGLE SIGNAL brand
Electric Timers
HG1 FLEXOPULSE
®
Repeat Cycle Timer
Repeat cycle timer
features separate dial
scales for ON and
OFF time
The HG1 is an ON-OFF repeat cycle timer engineered with the same
features as the rest of the plug-in CYCL-FLEX
6
■ Repeat cycle, two circuit timer housed in CYCL-FLEX
■ Separate dial scale for ON time and OFF time
E
L
T
■ Individually adjustable ON and OFF time intervals via concentric
E
I
C
T
R
I
C
knobs on front of unit
M
■ Combination of ON and OFF time equals total time cycle of unit
E
R
S
®
family.
OPERATION
A cycle progress pointer oscillates between the ON and OFF time
setpoints. As this pointer crosses the zero point on the dial, two internal
10 amp SPDT output switches transfer. The transfer point of the output
switches is adjustable to allow a make before break (overlap) or a break
before make (dwell) switch action. The overlap or dwell time interval is
limited to 1.5% of the total (ON plus OFF) time cycle.
A synchronous unidirectional motor drives the unit through precision
gearing. Instant reversing of the progress pointer is accomplished by
positive mechanical action.
SPECIFICATIONS
Time Ranges:
Sym.
00
01
02
03
04
05
06
07
08
09
10
Dial
Range
30 Sec.
60 Sec.
150 Sec.
5 Min.
10 Min.
30 Min.
60 Min.
150 Min.
5 Hr.
10 Hr.
30 Hr.
Minimum
Setting
.5 Sec.
1 Sec,
2 Sec.
5 Sec.
10 Sec.
30 Sec.
1 Min.
2 Min.
5 Min.
10 Min.
30 Min.
Max. Dwell
or Overlap
.5 Sec.
1 Sec.
2 Sec.
5 Sec.
10 Sec.
30 Sec.
1 Min.
2 Min.
5 Min.
10 Min.
30 Min.
®
plug-in case
®
RECOGNIZED
Voltage/Frequency: 120V, 60 Hz
240V, 60 Hz
Burden: 2.5 VA @ 120V AC
Output Rating: 10 amp 120 VAC, 5 amp 240 VAC Resistive
Mechanical Life: 10,000,000 operations
Switch Life: 250,000 under 10 amp, 120 VAC resistive load
1,000,000 under 5 amp, 120 VAC resistive load
Repeat Accuracy: 1/2 of 1% of dial
Temperature Range: -20˚ to 140˚F
Agency Approvals: UL Recognition E61735
CSA Certification LR26861
CERTIFIED
OPERATION
To Set
Move the black pointer to the desired OFF setting and the orange pointer
to the desired ON setting (as shown in Figure 1). The sum of these ON
and OFF intervals cannot exceed the total time of one scale. Switch
contacts are tripped open or closed each time the indicator pointer
passes 0. When the indicator pointer is in the OFF scale to the left of 0
contacts 4-3 and contacts 6-8 are closed and 4-5 and 6-7 are open.
When the indicator pointer is in the ON scale to the right side of 0
contacts 4-5 and 6-7 are closed and 4-3 and 6-8 are open. The indicator
pointer must travel to the preset limit and back to 0 to complete the total
ON or OFF interval. The two switches can operate together or be set to
allow a break before make (dwell) interval or make before break
(overlap) between ON-OFF switching. Refer to the standard time range
chart under specifications for the maximum dwell or overlap interval for
each time range. Figure 2 illustrates the path of the indicator pointer and
the switch action each time the zero point is passed. Figure 3 illustrates
the terminal location on the rear of the unit case.
®
6.16 DANAHER INDUSTRIAL CONTROLS
WIRING
BLACK
POINTER
MOUNTING
DRILL AND TAP FOUR
HOLES FOR 8-32 SCREWS
(INCLUDED W/UNIT)
1.406
(35.71)
1.406
(35.71)
15
20
10
1.406
(35.71)
5
60
55
50
45
40
25
+
3.187 .062
+
(80.95 1.57)
DIA. CUTOUT
N
O
35
30
Figure 1
1.406
(35.71)
O
30
35
F
F
60
5
25
55
10
50
15
20
45
40
MTG. HOLE
USED FOR
GROUNDING
CASE
INDICATOR
POINTER
ORANGE
POINTER
OFF
SETTING
3.812
(96.82)
ON
SETTING
6
7
8
9
5
4
3
7
6
8
Figure 2
5
4
3
7
6
8
10
TERMINAL ARRANGEMENT
Figure 3
5
M
11
12
CONTACTS SHOWN IN
"ON" POSITION
4
3
2
1
6
T
O
4.250
(107.95)
3.062
(77.77)
4.125
(104.78)
5.750
(146.05)
1.625
(41.27)
E
T
L
T
E
A
I
C
L
M
T
E
I
R
R
Z
I
S
I
C
N
G
ENCLOSURES
Model No. NEMA Class Description
HN308 1 Surface Mtg. with terminal block
HN364 1 Surface Mtg. without terminal block
HN370 1A Dual unit cabinet less unit cases and
ACCESSORIES
Model No. Description
H-5331 Mounting Brackets 2 req'd per timer
HP50-31 One Hole Mounting Ring
HP50-133 Surface Mounting Adapter to use in place of brackets
toggle switch, with 9 terminal block
ORDERING INFORMATION
Consult Customer Service for availability of other time ranges, voltages, and frequencies.
HG1 01 A6 05
TIME RANGE
See Specifications for
Time Range Catalog Symbol
VOLTAGE &
FREQUENCY
Sym. Description
A5
A6
B5
B6
120V, 50 Hz
120V, 60 Hz
240V, 50 Hz
240V, 60 Hz
FEATURES
Sym.
Revised for Mounting in Explosion Proof
05
Description
Housing
Enclosed in HN388 Explosion Proof Housing
92