EAGLE SIGNAL brand
Electronic Timers
CX200 Microprocessor Timer/Counter
Microprocessor based
solid state timer/
counter... housed in
CYCL-FLEX
®
case
5
E
L
T
The CX200 is a microprocessor based timer/counter housed in a
E
I
C
standard 15 terminal CYCL-FLEX® plug-in case. Time or count
M
T
operation, time range, and standard or reverse start operation is
E
R
selected by 7 miniature rocker switches located inside the unit housing.
R
O
Time or count setpoints are entered into the unit using a sealed
S
T
N
membrane keypad on the front of the unit. Each digit in the setpoint is
I
I
individually increased or decreased by pressing the appropriate keypad
M
C
switch. Time or count setpoint and progress is displayed on the front of
E
R
the unit by a 4 1/2 digit liquid crystal display with .5 inch digits. Time or
S
count subtracts from the setpoint and the output changes state at zero.
Operational mode annunicators also appear in the display area on the
front of the unit. The mode annunciator flashes when the unit is timing
or counting.
■ Five time ranges from 19.999 sec. to 199 hrs.: 59 min.
■ Two count rates - accept and display counts from 1 to 19999
■ Two relay outputs - socket mounted for easy replacement
■ Two form C instantaneous contacts and two form C programmed
contacts
■ N.O. solid state MOSFET, delayed action switch rated at 1 ampere
continuous load current, 0-264 VAC 50/60 Hz or DC
■ Ideal output for switching low level signals and high voltage loads
due to MOSFET output's ON resistance of 0.5 ohm and very low
OFF leakage
■ Programmed outputs operate in one of four load sequences; OOX,
OXO, OOX with pulse output, and OOX pulse output with repeat
cycle operation
■ Standard start is defined as ON delay reset timer or counter
■ For standard start units, timer/counter resets on power failure
■ Reverse start or OFF delay units will not reset on power failure and
will continue cycle when power is restored
■ Non-volatile memory data retention
®
RECOGNIZED
®
CERTIFIED
SPECIFICATIONS
Time/Count Ranges:
Sym.
1
2
3
4
5
6
7
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
B6 - 240 VAC, 50/60 Hz
K6 - 208 VAC, 50/60 Hz
Time Inhibit/Count Line Voltage/Frequency:
A6 - 120 VAC 50/60 Hz
B6 - 240 VAC 50/60 Hz
K6 - 208 VAC 50/60 Hz
Setting Accuracy: Time: ±0.1% or 50 ms, whichever is larger (0˚ to 60˚C)
Count: 100%
Repeat Accuracy:
Time: ±0.001% of setting or 35 ms, whichever is larger (0˚ to 60˚C)
Count: 100%
Reset Time: 30 ms following voltage removal from simulated clutch input
(CR1)
Power on Response: 300 ms maximum after voltage applied to terminal 11
Operating Temperature: +32˚ to +140˚F (0˚ to +60˚C)
Output Rating: Relay: 10 amp (resistive), 120 VAC
Mechanical Life: 20 million operations
Electrical Life: contingent upon controlled load
Solid State: 1 amp, 0-264 VAC, VDC
Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magni-
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
Agency Approvals: UL Recognition E96337
CSA Certification LR26861
Maximum
Range
19999 Cts.
19999 Cts.
199.99 Sec.
1999.9 Sec.
19.999 Sec.
199 Min.: 59 Sec.
199 Hr.: 59 Min.
Minimum
Setting
1 Ct.
1 Ct.
.01 Sec.
.1 Sec.
.001 Sec.
1 Sec.
1 Min.
Count
Rate
500/Min. AC.
5000/Min. AC
5.32
DANAHER SENSORS & CONTROLS
CX200 TERMINAL ASSIGNMENTS TERMINALS AND WIRING DIAGRAM ON REAR
OF TIMER CASE
T/C
CR2
2
6
7
8
3
9
10
11
5
B
4
T/C
CR2
A
12
CR1
1
3
2
1
*
B
INSTANTANEOUS
*COUNT INPUT/TIME INHIBIT
CR1
6
9
CONTACTS
11
8
7
4
10
PROGRAMMED
T/C
CR2
A
12
3
5
CONTACTS
2
1
*
B
*COUNT INPUT/TIME INHIBIT
CR1
11
4
1 AMPHERE
SOLID STATE
MOSFET SWITCH
MOUNTING
DRILL AND TAP FOUR
HOLES FOR 8-32 SCREWS
(INCLUDED W/UNIT)
+
1.406
(35.71)
1.406
(35.71)
3.187 .062
+
(80.95 1.57)
DIA. CUTOUT
4.250
(107.95)
3.062
(77.77)
5
T
E
L
O
T
E
T
I
C
A
M
T
L
E
R
R
I
O
S
N
Z
I
I
C
N
G
1.406
(35.71)
1.406
(35.71)
MTG. HOLE
USED FOR
GROUNDING
CASE
ENCLOSURES
Model No. NEMA Class Description
HN308 1 Surface Mtg. with terminal block
HN364 1 Surface Mtg. without terminal block
HN370 1A Dual unit cabinet less unit cases and
toggle switch, with 9 terminal block
ORDERING INFORMATION
CX2 02 A6
OUTPUT TYPE
Sym.
02
42
Description
10 amp Relay Output
1 amp Solid State MOSFET
3.812
(96.82)
4.125
(104.78)
5.750
(146.05)
ACCESSORIES
Model No. Description
H-5331 Mounting Brackets 2 req'd per timer
HP50-31 One Hole Mounting Ring
HP50-131 CYCL-FLEX Water-Sealed Housing
HP50-133
PDM-534 1/4 DIN Adapter Plate
Surface Mounting Adapter to use in place of brackets
VOLTAGE & FREQUENCY
Sym. Description
120 VAC, 50/60 Hz
A6
240 VAC, 50/60 Hz
B6
208 VAC, 50/60 HZ
K6
1.625
(41.27)
DANAHER SENSORS & CONTROLS
5.33