The CX100 is a solid state repeat cycle timer that will alternately turn an
E
I
C
output on and off as long as power is applied to the unit. The CX100 is
M
T
a microprocessor based timer with digital setting for greater setting
E
R
accuracy than can be achieved with analog style repeat cycle timers. In
R
O
addition to its greater setting accuracy, the CX100 timer is fully
S
T
N
programmable to provide a number of time ranges and operating
I
I
modes in one unit.
M
C
E
The ON and OFF time ranges are individually programmable for four
R
time ranges from 199.99 seconds to 199 hours and 59 minutes. The
S
CX100 timer is also programmable to have the ON time first instead of
the OFF time first and to reset or non-reset on power interruption. The
time ranges and the operating characteristics of the unit are programmed using 7 miniature rocker switches located inside the unit
housing.
■ Housed in standard CYCL-FLEX
programming changes, and service
■ 4 1/2 digit (19999) liquid crystal display - .5 inch high
■ Annunciators (right of the display) flash to indicate ON time cycle
and are constantly on to indicate OFF time cycle
■ Two socket mount 10 amp output relays - one performs ON/OFF
cycle switching and the other is a set of instantaneous contacts that
energize when power is applied to the start input and do not
deenergize until power is disconnected from the start input
■ Time inhibit input allows timing function to be stopped without
resetting the unit
■ Non-volatile memory data retention
®
enclosure for easier removal,
CX100 Repeat Cycle Timer
CX100 Repeat Cycle Timer
CX100 Repeat Cycle Timer
Continuously runs
cycles with
independently
settable on/off ratio
®
®
®
®
®
RECOGNIZED
RECOGNIZED
RECOGNIZED
SPECIFICATIONS
Time Ranges:
Maximum
Maximum
Maximum
Range
Range
Range
199.99 Sec.
199.99 Sec.
199.99 Sec.
1999.9 Sec.
1999.9 Sec.
1999.9 Sec.
199 Min.: 59 Sec.
199 Min.: 59 Sec.
199 Min.: 59 Sec.
199 Hr.: 59 Min.
199 Hr.: 59 Min.
199 Hr.: 59 Min.
Operating Voltage/Frequency:
A6 - 120 VAC, 50/60 Hz
B6 - 240 VAC ,50/60 Hz
Setting Accuracy: ±0.05% or 50 ms, whichever is larger (0˚ to 60˚C)
Repeat Accuracy:
±0.001% of setting or 35 ms, whichever is larger (0˚ to 60˚C)
Reset Time: 30 ms following voltage removal from simulated clutch input
(CR1)
Power on Response: 300 ms maximum after voltage applied to terminal 11
Operating Temperature: +32˚ to +140˚F (0˚ to +60˚C)
Output Rating: Relay: 10 amp (resistive), 120 VAC
Mechanical Life: 20 million operations
Electrical Life: contingent upon controlled load
Vibration: Unit function is unaffected by 2.5G sinusoidal vibration magni-
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
Approvals: UL Recognition E96337
CSA Certification LR26861
Minimum
Minimum
Minimum
Setting
Setting
Setting
.01 Sec.
.01 Sec.
.01 Sec.
.1 Sec.
.1 Sec.
.1 Sec.
1 Sec.
1 Sec.
1 Sec.
1 Min.
1 Min.
1 Min.
CERTIFIED
CERTIFIED
CERTIFIED
®
5.38
DANAHER SENSORS & CONTROLS
OFF Time First/Repeat Cycle Operation
START
PROGRAMMED CONTACT
OPERATION
OFF
ON
ON Time First/Repeat Cycle Operation
START
PROGRAMMED CONTACT OPERATION
ON
OFF
MOUNTING
DRILL AND TAP FOUR
HOLES FOR 8-32 SCREWS
(INCLUDED W/UNIT)
+
1.406
(35.71)
1.406
(35.71)
3.187 .062
+
(80.95 1.57)
DIA. CUTOUT
4.250
(107.95)
CX100 TERMINAL ASSIGNMENTSOUTPUT OPERATING MODES
T/C
CR2
7
5
10
8
CONTACTS
2
5
T
E
L
O
T
E
T
I
C
A
M
T
L
E
R
R
I
O
S
N
Z
I
I
C
N
G
3.062
(77.77)
1
B
11
A
12
C
INSTANTANEOUS
CONTACTS
6
9
PROGRAMMED
1.406
(35.71)
1.406
(35.71)
MTG. HOLE
USED FOR
GROUNDING
CASE
ENCLOSURES
Model No. NEMA Class Description
HN308 1 Surface Mtg. with terminal block
HN364 1 Surface Mtg. without terminal block
HN370 1A Dual unit cabinet less unit cases and
toggle switch, with 9 terminal block
ORDERING INFORMATION
CX1 00 A6
OUTPUT TYPE
Sym.
00
Description
10 amp Relay Output
3.812
(96.82)
4.125
(104.78)
5.750
(146.05)
ACCESSORIES
Model No. Description
H-5331 Mounting Brackets 2 req'd per timer
HP50-31 One Hole Mounting Ring
HP50-131 CYCL-FLEX Water-Sealed Housing
HP50-133
Surface Mounting Adapter to use in place of brackets
VOLTAGE & FREQUENCY
Sym. Description
120 VAC, 50/60 Hz
A6
240 VAC, 50/60 Hz
B6
1.625
(41.27)
DANAHER SENSORS & CONTROLS
5.39