Eagle Signal B856 Data Sheet

EAGLE SIGNAL brand
Electronic Timers
E L
T
E
I
An excellent value in its class, the B856 features a compact
C
M
T
1/16 DIN package, precise digital setting, versatile functionality, and a
E
R
straightforward button-per-digit interface.
R
O
S
T
N
It can be easily programmed to perform any standard timing operation:
I
I
On-Delay, Off-Delay, Interval, or Repeat Cycle. A unique On-Delay/
M
C
Interval Mode can, in many cases, perform the function of two separate
E
timers. Output is via DPDT relay contacts.
R
S
Five selectable time ranges and a programmable decimal point provide preset times ranging from 0.01 seconds to 9999 hours.
A standard model features a timed DPDT contact output while another model includes separate timed and instantaneous SPDT contacts. All are rated for 5 Amp loads.
Simplicity of operation is maintained while still providing a high level of functionality. All programming is done through the front panel, with an intuitive button-per-digit keypad that makes entry of preset times quick and easy. A crisp dual line LCD display lets the operator readily view elapsed or remaining cycle time as well as the preset value. Prominent annunciators indicate information such as the time range and the status of the input and outputs.
Button-per-digit preset entry simplifies setup and operation
High Contrast dual line LCD display indicates both Process Time and
Preset Value
Field selectable for operation in On-Delay, Off-Delay, Interval 1,
Interval 2, or Repeat Cycle modes
Universal Power Supply accepts 24 - 240 VAC or 24 VDC
Designed to meet IEC 801 level 4 noise immunity standards for
increased reliability
Unique On-Delay/Interval mode lets one unit do the work of two in
many applications
Industry standard socket connection
Programmable security levels prevent unauthorized setpoint or
program changes
UL, CUL recognized, CE compliant
IEC IP65 rated front panel for use in washdown environments
Reliability is a key feature of the B856. IEC level 4 noise immunity ensures flawless operation in harsh electrical environments. Its IEC IP65 enclosure rating allows use in washdown conditions.
Wiring via an industry standard 11 or 8 pin socket and a power supply that can accept 24 - 240 VAC or 24 VDC vastly simplifies setup.
B856 Multi-Function Timer
High accuracy digital timer features dual line LCD and multiple ranges Every popular operating mode in a compact 1/16 DIN package
File No.: E96337
®
RECOGNIZED
SPECIFICATIONS
Inputs:
Start : NPN or Dry Contact Reset : NPN or Dry Contact
Outputs:
Timed (B856-500): DPDT - 5 amp Timed (B856-501 & -511): SPDT - 5 amp Instantaneous (B856-511): SPDT - 5 amp Activation Time: 15 msec. max.
Physical:
Dimensions: 48mm x 48mm, 81mm deep Mounting: Panel Mounting in 45 x 45 cutout or DIN rail Wiring Connection: Via 8 pin (B856-501) or 11 pin (B856-500 &
-511) plug-in socket
Operation:
Supply Voltage: 24 - 240 VAC 50/60Hz or 24 VDC Power Consumption: 50 VA @ 240 VAC Time Ranges: Field Selectable for Hours, Minutes, Seconds,
Hours:Minutes, Minutes:Seconds
Resolution: Field selectable from XXXX to XX.XX for Hours, Minutes
and Seconds
Operating Modes: On-Delay, Off-Delay, Interval 1, Interval 2, Repeat,
On-Delay/Interval
Repeat Accuracy: Electrical Service Life: 100,000 cycles at full load Mechanical Service Life: 10 million cycles at min. load
Environmental:
Front Panel Rating: IEC IP65 Operating Temperature: 0° to 60° C (B856-500);
0° to 55° C (B856-501); 0° to 50° C (B856-511)
Storage Temperature: -40° to 90° C Humidity: 5% to 95% RH non-condensing Weight: 100 grams (3.5 ounces)
Approvals:
B856-500 & -501: UL and CUL recognized, CE marked B856-511: UL and CUL recognized
+ 0.03%
C
®
RECOGNIZED
5.06
DANAHER INDUSTRIAL CONTROLS
OPERATING MODES
48mm
8mm
66mm
48mm
EAGLE SIGNAL
15mm
On-Delay
Timing begins on the leading edge of the start input. The output will activate at the completion of the preset time (T) and will remain active until the reset signal is applied or power is interrupted.* For B856­511, the instantaneous output will activate upon the start signal and will remain active until the reset signal is applied or power is interrupted.*
Off-Delay
The output is activated at the leading edge of the start signal. Timing begins on the trailing edge. The output will remain active until the preset time (T) has elapsed or power is interrupted.* Reapplying the start signal before T has elapsed will reset the time value. The reset input is not used.
Interval 1
On the leading of the start input, the output is activated and timing begins. The output will remain active until the preset time (T) has elapsed or power is interrupted.* Removal of the start signal will also cause the ouput to be deactivated and the time value reset. The reset input is not used.
Power Start Output Reset
Instant. Output
Power Start
Output
Power Start
Output
Connections
B856-500 & -511 B856-501
4
3 2
1
or
24 VDC
Start
5
8
Power*
6 7
+
T
E
O
L
T
E
T
I
C
A
M
T
L
E
R
R
I
O
S
Z
N
I
I
C
N G
T
Start
5
4
3
2
Reset
6
7
8
9
10
11
1
Reset
Power
For the -511 version,
T
T
Pins 1, 3, 4 are the
instantaneous contacts
* 24–240 VAC
Dimensions:
T
T
Interval 2
On the leading of the start input, the output is activated and timing begins. The output will remain active until the preset time (T) has elapsed or power is interrupted.* The reset input is not used. Reapplying the start signal has no effect unless the cycle has completed.
Repeat Cycle
Timing begins on the leading edge of the start input. A cycle is initiated where the output will be OFF for the preset time (T), then ON for the preset time. This cycle will continue until a reset signal is applied or power is interrupted.* The unit can also be programmed for the timing sequence to begin with an ON cycle.
Delay/Interval
The delay cycle begins upon application of the start signal. The output will activate at the completion of the preset time (T1). Upon activation of the output, the Interval cycle will begin. The output will be deactivated at the end of the Interval time (T2). T1 is the primary preset value. T2 is settable from 0.1 to
999.9 seconds. The timing sequence and output can also be reset through the reset input or interruption of power.*
Power
Start
Output
Power Start Output
Reset
Power Start
Output Reset
T
Repeat Cycle
T
T
1
T
* The Power Reset parameter can be set so that a timing sequence will not be reset upon power interruption but instead continue on when power is restored.
T
T
2
T
ORDERING INFORMATION
Description Model
Multi-Function (11 Pin) Timer B856-500 As Above w/Instant Contacts B856-511 Multi-Function (8 Pin) Timer B856-501*
*For Drop-In Replacement of LX260 DC Version, Order B856-502
Accessories
B856-500 & -511: 11 Pin Socket 60SR3P06 11 Pin Socket - Outward PBT-03172 Facing Terminals B856-501: 8 Pin Socket 60SR2P06 8 Pin Socket - Outward PBT-03155 Facing Terminals
DANAHER INDUSTRIAL CONTROLS
5.07