EAGLE SIGNAL brand
Electronic Timers
5
E
L
T
E
I
An excellent value in its class, the B856 features a compact
C
M
T
1/16 DIN package, precise digital setting, versatile functionality, and a
E
R
straightforward button-per-digit interface.
R
O
S
T
N
It can be easily programmed to perform any standard timing operation:
I
I
On-Delay, Off-Delay, Interval, or Repeat Cycle. A unique On-Delay/
M
C
Interval Mode can, in many cases, perform the function of two separate
E
timers. Output is via DPDT relay contacts.
R
S
Five selectable time ranges and a programmable decimal point provide
preset times ranging from 0.01 seconds to 9999 hours.
A standard model features a timed DPDT contact output while another
model includes separate timed and instantaneous SPDT contacts. All
are rated for 5 Amp loads.
Simplicity of operation is maintained while still providing a high level of
functionality. All programming is done through the front panel, with an
intuitive button-per-digit keypad that makes entry of preset times quick
and easy. A crisp dual line LCD display lets the operator readily view
elapsed or remaining cycle time as well as the preset value. Prominent
annunciators indicate information such as the time range and the status
of the input and outputs.
■ Button-per-digit preset entry simplifies setup and operation
■ High Contrast dual line LCD display indicates both Process Time and
Preset Value
■ Field selectable for operation in On-Delay, Off-Delay, Interval 1,
Interval 2, or Repeat Cycle modes
■ Universal Power Supply accepts 24 - 240 VAC or 24 VDC
■ Designed to meet IEC 801 level 4 noise immunity standards for
increased reliability
■ Unique On-Delay/Interval mode lets one unit do the work of two in
many applications
■ Industry standard socket connection
■ Programmable security levels prevent unauthorized setpoint or
program changes
■ UL, CUL recognized, CE compliant
■ IEC IP65 rated front panel for use in washdown environments
Reliability is a key feature of the B856. IEC level 4 noise immunity
ensures flawless operation in harsh electrical environments. Its IEC
IP65 enclosure rating allows use in washdown conditions.
Wiring via an industry standard 11 or 8 pin socket and a power supply
that can accept 24 - 240 VAC or 24 VDC vastly simplifies setup.
B856 Multi-Function Timer
High accuracy digital timer
features dual line LCD and
multiple ranges… Every
popular operating mode in a
compact 1/16 DIN package
File No.: E96337
®
RECOGNIZED
SPECIFICATIONS
Inputs:
Start : NPN or Dry Contact
Reset : NPN or Dry Contact
Outputs:
Timed (B856-500): DPDT - 5 amp
Timed (B856-501 & -511): SPDT - 5 amp
Instantaneous (B856-511): SPDT - 5 amp
Activation Time: 15 msec. max.
Physical:
Dimensions: 48mm x 48mm, 81mm deep
Mounting: Panel Mounting in 45 x 45 cutout or DIN rail
Wiring Connection: Via 8 pin (B856-501) or 11 pin (B856-500 &
-511) plug-in socket
Operation:
Supply Voltage: 24 - 240 VAC 50/60Hz or 24 VDC
Power Consumption: 50 VA @ 240 VAC
Time Ranges: Field Selectable for Hours, Minutes, Seconds,
Hours:Minutes, Minutes:Seconds
Resolution: Field selectable from XXXX to XX.XX for Hours, Minutes
and Seconds
Operating Modes: On-Delay, Off-Delay, Interval 1, Interval 2, Repeat,
On-Delay/Interval
Repeat Accuracy:
Electrical Service Life: 100,000 cycles at full load
Mechanical Service Life: 10 million cycles at min. load
Environmental:
Front Panel Rating: IEC IP65
Operating Temperature: 0° to 60° C (B856-500);
0° to 55° C (B856-501); 0° to 50° C (B856-511)
Storage Temperature: -40° to 90° C
Humidity: 5% to 95% RH non-condensing
Weight: 100 grams (3.5 ounces)
Approvals:
B856-500 & -501: UL and CUL recognized, CE marked
B856-511: UL and CUL recognized
+ 0.03%
C
®
RECOGNIZED
5.06
DANAHER INDUSTRIAL CONTROLS
OPERATING MODES
48mm
8mm
66mm
48mm
EAGLE SIGNAL
15mm
On-Delay
Timing begins on the leading
edge of the start input. The
output will activate at the
completion of the preset time
(T) and will remain active until
the reset signal is applied or
power is interrupted.* For B856511, the instantaneous output will
activate upon the start signal and
will remain active until the reset
signal is applied or power is
interrupted.*
Off-Delay
The output is activated at the
leading edge of the start signal.
Timing begins on the trailing edge.
The output will remain active until
the preset time (T) has elapsed or
power is interrupted.* Reapplying
the start signal before T has
elapsed will reset the time value.
The reset input is not used.
Interval 1
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
Removal of the start signal will
also cause the ouput to be
deactivated and the time value
reset. The reset input is not used.
Power
Start
Output
Reset
Instant.
Output
Power
Start
Output
Power
Start
Output
Connections
B856-500 & -511 B856-501
4
3
2
1
–
or
24 VDC
Start
5
8
Power*
6
7
+
5
T
E
O
L
T
E
T
I
C
A
M
T
L
E
R
R
I
O
S
Z
N
I
I
C
N
G
T
Start
5
4
3
2
Reset
6
7
8
9
10
11
1
Reset
Power
For the -511 version,
T
T
Pins 1, 3, 4 are the
instantaneous contacts
* 24–240 VAC
Dimensions:
T
T
Interval 2
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
The reset input is not used.
Reapplying the start signal has no
effect unless the cycle has
completed.
Repeat Cycle
Timing begins on the leading edge
of the start input. A cycle is
initiated where the output will be
OFF for the preset time (T), then
ON for the preset time. This cycle
will continue until a reset signal
is applied or power is interrupted.*
The unit can also be programmed
for the timing sequence to begin
with an ON cycle.
Delay/Interval
The delay cycle begins upon
application of the start signal. The
output will activate at the completion
of the preset time (T1). Upon
activation of the output, the Interval
cycle will begin. The output will be
deactivated at the end of the Interval
time (T2). T1 is the primary preset
value. T2 is settable from 0.1 to
999.9 seconds. The timing
sequence and output can also be
reset through the reset input or
interruption of power.*
Power
Start
Output
Power
Start
Output
Reset
Power
Start
Output
Reset
T
Repeat Cycle
T
T
1
T
* The Power Reset parameter can be set so that a
timing sequence will not be reset upon power
interruption but instead continue on when power is
restored.
T
T
2
T
ORDERING INFORMATION
Description Model
Multi-Function (11 Pin) Timer B856-500
As Above w/Instant Contacts B856-511
Multi-Function (8 Pin) Timer B856-501*
*For Drop-In Replacement of LX260 DC Version, Order B856-502
Accessories
B856-500 & -511:
11 Pin Socket 60SR3P06
11 Pin Socket - Outward PBT-03172
Facing Terminals
B856-501:
8 Pin Socket 60SR2P06
8 Pin Socket - Outward PBT-03155
Facing Terminals
DANAHER INDUSTRIAL CONTROLS
5.07