Eagle Signal A103-006 Technical Manual

Introduction
Eagle Signal
brand
Within the Danaher Controls A103 family you'll find a product to meet nearly every requirement for panel mounted control and indication. Housed in a DIN standard 36mm x 72mm case, the A103-006 is designed to accumualate elapsed time for applications such as machine maintenance. The unit is field programmable to display the elapsed time in a variety of units.
The supertwist LCD display with 6 digit display, plus time unit legend, provides easy viewing at a glance. For conditions where ambient light is poor, the display can be backlit by connecting an external DC (10-28 Volt) power supply. The time value can either be reset through the front panel or via a remote signal.
Powered by either one or two replaceable 3V Lithium batteries, this unique design allows for a new battery to be installed before removing the old one, thereby retaining count total and program data. A low battery indicator appears on the screen to provide a warning several weeks before the end of battery life. If two batteries are used simultaneously, the individual expected life doubles to 10 years.
Setup is quick and simple as the two front panel keys are used to scroll through 2 menu choices. A NEMA 4X front panel and noise immunity tested to IEC 801 level 3 makes this unit suitable for harsh environments. Several option modules are also available that provide added functionality and convenience.
Technical Manual 701954-0007
Features
Large, easy to read 6-digit supertwist LCD display with backlighting capability
3 Volt lithium battery provides long life and eliminates the need for external power
Elapsed time resettable remotely or from the front panel (if enanbled)
Field programmable time units: Seconds, Minutes, Hours, Hours:Minutes:Seconds
Option Modules provide added functionality and convenience
Simple menu-driven setup
NEMA 4X rated front panel for use in washdown environments
Index
Overview
Setup
General
Operation page 2 Terminal Connections page 2
Installation page 3 Programming page 3
Specifications page 4 Warranty page 4
A103-006 Elapsed Time Indicator
1
OVERVIEW
OPERATION
EAGLE SIGNAL
345678S
R
1. Time Display 3. Next/Reset Key
2. Down Key
1. Time Display: Accumulates time when the timing start input is active. Timing will not take place when the external or front panel reset is active. The leftmost digit is the time value legend.
2. Down Key: When the program input is active this key is used to scroll through the menu items. After a menu item has been chosen for editing, the down key is used to set the value for the currently selected (flashing) digit.
REAR TERMINAL CONNECTIONS
3. Next/Reset Key: Resets the accumulated time if Front Panel Reset is enabled in Programming Mode. When the program input is active this key is used to select a menu item for editing (left most digit will begin to flash) and then move to the desired digit to be changed.
VEEDER-ROOT
4 3 2 1
1. Common
2. Not Used
3. Timing Enable - NPN or dry contact inputs
4. Remote Reset - Resets time value when tied to common
2
5 6 7 8
10 - 28 VDC
5. Front Panel Program Enable - Allows access to program mode when tied to common
6. Not Used
7. Not Used
8. DC Supply Input - For backlighting
+
-