Eagle AGGHTS Parts List

PART #335375
Gas Griddles
Installation & Operating Instructions
Models #AGGH, AGGHT and AGGHTS SERIES
Retain this manual for future reference.
Contact this factory, the factory representative or a local service company to perform maintenance and repairs.
INSTALLATION INSTRUCTIONS
(See page 5 for Operating Instructions.)
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
BEFORE PLACING THIS APPLIANCE IN OPERATION, CONTACT YOUR LOCAL GAS SUPPLIER AS TO WHAT INSTRUCTIONS ARE TO BE FOLLOWED IF YOU SMELL GAS. THE INSTRUCTIONS OBTAINED SHOULD THEN BE POSTED IN A PROMINENT LOCATION.
This griddle is designed for installation as an independent HEAVY DUTY APPLIANCE and is not intended for residential use.
CLEARANCE INSTRUCTIONS
Appliances for installation on non-combustible countertops only. "Minimum clearance from combustible construction is 6 inches from the sides, 6 inches from the back and 48 inches from top of the griddle".
The appliance area must be free and clear of all combustible items.
The unit must be leveled before placing it in operation. To level the unit on an uneven surface to prevent rocking, adjustable feet have been provided.
When using gas griddle, keep the appliance area free from obstructions that could block the flow of combustible gases.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. DO NOT TOUCH ELECTRIC SWITCHES
2. EXTINGUISH ANY OPEN FLAME
3. IMMEDIATELY CALL YOUR GAS COMPANY
EG9808 Revised 10/00
100 Industrial Boulevard, Clayton, Delaware 19938 U.S.A. www.eaglegrp.com
Phone: 302/653-3000 (Fdsrv) 800/441-8440 (MHC/Retail) 800/637-5100 Fax: 302/653-2065 or 302/653-3036
Eagle Foodservice Equipment, Eagle MHC, Level-Lok Inc., and SpecFAB are divisions of Eagle Group. ©2000 by the Eagle Group
INSTALLATION INSTRUCTIONS (continued)
GAS CONNECTIONS
Installation Personnel: Check all connections and fittings on valves and tubing supplied as a part of this unit to make sure they did not come loose during shipment. A manual gas valve should be provided upstream within 6 feet of the appliance for shutting the gas off during servicing. A ground joint union should be provided between the house plumbing and the gas inlet to the appliance. A gas pressure regulator has been provided as a part of this appliance. It is factory pre-set for natural gas and is field adjustable for liquid propane gas. All plumbing should be clean and free of burrs and metal chips. All pipe connections should be made using a pipe joint compound resistant to the action of LP gases. A drip TEE must be used to collect any moisture or dirt in the gas. Upon completing the installation of this appliance, all the gas connections must be checked for gas leaks. Use a solution of liquid dishwashing soap and water to check for leaks. On models with safety pilot, check the lighter tube for correct position.
This installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code ANSI Z223.1, National Gas Installation code, CAN/CGA-B149.1, or The Propane Installation Code, CAN/CGA-B149.2 as applicable.
The appliance and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1⁄2 psig (3/45 kPa).
The appliance must be isolated from the gas supply piping system by closing it’s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2˝ psig (3.45 kPa).
Provisions for proper air supply must be taken into account when installing the unit. Care should be taken so as not to obstruct the area in front and in rear of the unit. DO NOT PLACE BACK OF THE UNIT CLOSER THAN 6 INCHES TO A WALL OR OTHER SURFACES.
The appliance shall be located with respect to other equipment so it will have adequate clearances for servicing and proper operation.
This unit is supplied with four (4) adjustable feet, which must be installed prior to operation. Four (4)-threaded openings are provided on bottom of the unit to accept the threaded portion of the feet. Screw in the feet and tighten them securely. During operation, check the feet every sixty- (60) days to assure that they are tight. Failure to use the feet will void warranty and could cause unsafe conditions.
NOTE: Appliance must be installed under a ventilation hood.
LEVELING UNIT
Level unit by adjusting the four (4) feet, which have an adjustment of one inch for line-up with other Eagle Countertop lines.
2
Loading...
+ 4 hidden pages