E1DT E1DT-ASSY-0058, E1DT-ASSY-0059 Installation And Operation Manual

E1DT
E1/PRI Splitter/Buffer
Copyright © 2005-2010 Somerdata Ltd.
INSTALLATION AND OPERATION
Applicable Products
E1DT - E1/PRI Splitter / Buffer
Part Numbers: E1DT-ASSY-0058 E1DT-ASSY-0059
E1DT-MAN-P112, Issue 4
Publication Date
31 October 2010
Published by
Somerdata Ltd. 1 Riverside Business Park St Annes Road Bristol
BS4 4ED UK
Sales & Customer Support
Phone: +44 (0)1179-634050 Fax: +44 (0)1173 -302929 E-Mail: sales@somerdata.com
support@somerdata.com
Website: www.somerdata.com
E1DT E1/PRI Splitter/Buffer
Installation and Operation
REVISION HISTORY
Issue
Date
Notes
4
Oct 2010
Contact details amended
3
21 Nov 2008
Updated
2
13 Feb 2008
Updated
1
2 Mar 2006
First Published
E1DT E1/PRI Splitter/Buffer
Installation and Operation
CONTENTS
1. INTRODUCTION 1-1
14BSCOPE 1-1 16BUSER GUIDES 1-1
2. PRODUCT DESCRIPTION 2-1
INTRODUCTION 2-1 AVAILABLE VERSIONS 2-2
E1DT-ASSY-0058 2-2 E1DT-ASSY-0059 2-2
3. POWER CONNECTION 3-1
POWER SOURCE 3-1
4. E1DT-ASSY-0058 SIGNAL CONNECTIONS 4-1
INTRODUCTION 4-1 INPUT/OUTPUT CONNECTOR PINOUTS 4-2
5. E1DT-ASSY-0059 SIGNAL CONNECTIONS 5-1
INTRODUCTION 5-1 INPUT/OUTPUT CONNECTOR PINOUTS 5-2
6. SPECIFICATIONS 6-1
LINE INTERFACE 6-3
SIGNAL 6-3 LINE CODE 6-3 DATA TYPE 6-3 SIGNAL AMPLITUDE 6-3 LINE CONNECTION 6-3 UN-POWERED PERFORMANCE 6-3
BUFFER 6-4
MONITOR OUTPUTS (STREAM A AND STREAM B) 6-4 INPUT IMPEDANCE 6-4 MONITOR OUTPUT IMPEDANCE 6-4 MONITOR OUTPUT LEVEL 6-4 MONITOR OUTPUT SIGNAL PRESENCE INDICATORS 6-4
E1DT E1/PRI Splitter/Buffer
Installation and Operation
MONITOR OUTPUT ISOLATION 6-4 INSERTION LOSS 6-4 OUTPUT TO INPUT GAIN VARIATION 6-4 OUTPUT BALANCE ERROR 6-4 NOISE (NO SIGNAL, LOADED INPUT) 6-4 CROSSTALK (STANDARD INPUT) 6-4 MAXIMUM INPUT VOLTAGE 6-4 OUTPUT DRIVE CAPABILITY 6-5 OUTPUT DRIVE ATTENUATION 6-5
UN-POWERED PERFORMANCE 6-5
CROSSTALK 6-5 RESIDUAL OUTPUT 6-5 INPUT SIGNAL LOADING 6-5
POWER REQUIREMENTS 6-5
VOLTAGE 6-5 CURRENT 6-5 CONNECTOR 6-5 POWER-ON INDICATION 6-5 AC ADAPTERS 6-5
ENVIRONMENTAL 6-6
TEMPERATURE 6-6 RELATIVE HUMIDITY 6-6
PHYSICAL 6-6
DIMENSIONS 6-6 WEIGHT 6-6
7. 5BSUPPORT 7-1
47BWHAT TO DO IF YOU HAVE A PROBLEM 7-1 48BSERVICING, MAINTENANCE AND REPAIRS 7-1 49BIF YOU NEED SUPPORT 7-2 50BSOMERDATA CONTACT INFORMATION 7-2 51BSUPPORT REQUESTS 7-3 52BRETURNS 7-4 53BEND-OF-LIFE DISPOSAL 7-5 54BWASTE OF ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE) 7-5
E1DT E1/PRI Splitter/Buffer
Installation and Operation
8. 6BWARRANTY 8-1
55BINTRODUCTION 8-1 56BWARRANTY: TERMS AND CONDITIONS 8-2
9. 8BNOTICES 9-1
55BGENERAL INFORMATION 9-1 DECLARATION OF CONFORMITY 9-2 SOMERDATA AND THE ENVIRONMENT 9-3
69BINTRODUCTION 9-3 70BCURRENT COMPLIANCE ACTIVITIES 9-3 71BRESTRICTION OF USE OF HAZARDOUS SUBSTANCES (ROHS) 9-4
10. INDEX 10-1
E1DT E1/PRI Splitter/Buffer
Installation and Operation
This page intentionally blank
E1DT E1/PRI Splitter/Buffer
Installation and Operation 1-1
1. INTRODUCTION
In this Section
14BSCOPE 1-1 16BUSER GUIDES 1-1
14BScope
This User Guide covers SomerData E1DT E1/PRI Splitter/Buffer.
16BUser Guides
Printed copies can be supplied on request. Please contact your local supplier or SomerData for ordering details.
Electronic copies (Adobe Acrobat files) are included on the SomerData CD-ROM that is supplied with the original products.
Additional and updated copies of the CD-ROM can be supplied on request. Please contact your local supplier or SomerData for ordering details.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 1-2
This page intentionally blank
E1DT E1/PRI Splitter/Buffer
Installation and Operation 2-1
2. PRODUCT DESCRIPTION
In this Section
INTRODUCTION 2-1 AVAILABLE VERSIONS 2-2
Introduction
E1DT E1 Splitter/Buffer provides a means of monitoring and
capturing traffic flowing in both directions of a 2Mbits/s E1/PRI (G.703/G.704) communications link.
The line connections are made through two RJ-45 connectors that are hard-wired in parallel. All line activity is passed­through the Splitter/Buffer. Monitoring and recording equipment can be connected or disconnected without disturbing the line.
Line signals are split and fed into high-impedance buffers that load the line signals by less than 0.1dB. Low-impedance outputs allow the monitoring equipment to be located up to 50m away from the line connection.
The design ensures that there is no interruption of the line signals when the Splitter/Buffer is unpowered.
LED indicators are provided for power (green) and signal (amber) presence at each monitor output connector.
E1DT operates from +6v to +12V DC power. UK and
European AC power adapters are available as options.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 2-2
Available Versions
Two versions of E1DT are available.
E1DT-ASSY-0058
Provides the monitor outputs on a single RJ-45 connector (Stream A pins 1/2 and 4/5) for use with devices that monitor both Tx and RX on the same input connector.
This version is not compatible with SomerData PC-VDR E1/PRI Recorders and R2D3 Data Capture Cards.
E1DT-ASSY-0059
Provides the monitor outputs on two RJ-45 connectors (pins 1 & 2) for use with devices that monitor Tx and RX on two input connectors.
This version is compatible with SomerData PC-VDR E1/PRI Recorders and R2D3 Data Capture Cards.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 3-1
3. POWER CONNECTION
In this Section
POWER SOURCE 3-1
Power Source
Recommended power source is a standard 6V, 9V or 12V regulated 100mA power supply with 2.1 mm (centre positive) low voltage connector.
An unregulated power supply can be used provided that the input voltage to E1DT does not exceed 12V.
UK and European AC power adapters are available as options.
+6 Volts DC to +12 Volts DC
0 Volts
E1DT E1/PRI Splitter/Buffer
Installation and Operation 3-2
This page intentionally blank
E1DT E1/PRI Splitter/Buffer
Installation and Operation 4-1
4. E1DT-ASSY-0058 SIGNAL CONNECTIONS
In this Section
INTRODUCTION 4-1 INPUT/OUTPUT CONNECTOR PINOUTS 4-2
Introduction
Both Tx and Rx monitor outputs are on a single RJ-45 connector (Stream A).
E1DT-ASSY-0058 should not be used with a SomerData PC-VDR E1/PRI Recorder or R2D3 E1/PRI Data Capture Card (see E1DT-ASSY-0059).
Connections should be made using standard CAT5 (1:1) cable.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 4-2
Input/Output Connector Pinouts
.
This product is not approved for connection to public
telecommunications systems. It is the User’s responsibility to ensure
that this equipment is used in compliance with appropriate legislation relating to connection with telecommunications networks.
Monitor Outputs
Pin
Stream A
1
Output +ve
Tx direction
2
Output -ve
3
Ground
4
Output +ve
RX direction
5
Output -ve
6
Not used
7
Not used
8
Not used
Line Input/Output
Pin Pin
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
E1DT E1/PRI Splitter/Buffer
Installation and Operation 5-1
5. E1DT-ASSY-0059 SIGNAL CONNECTIONS
In this Section
INTRODUCTION 5-1 INPUT/OUTPUT CONNECTOR PINOUTS 5-2
Introduction
Tx and Rx monitor outputs are on two RJ-45 connectors. Stream A for the Line Tx bitstream and Steam B for the Line Rx
bitstream. Both bitstreams appear on the Tx pins of the monitor output
connectors for compatibility with with SomerData PC-VDR E1/PRI Recorders and R2D3 E1/PRI Data Capture Cards.
Connections should be made using standard CAT5 (1:1) cable.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 5-2
Input/Output Connector Pinouts
Monitor Outputs
Pin
Stream A
Stream B
1
Output +ve
Output +ve
2
Output -ve
Output -ve
3
Ground
Ground
4
Not used
Not used
5
Not used
Not used
6
Not used
Not used
7
Not used
Not used
8
Not used
Not used
Line Input/Output
Pin Pin
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-1
6. SPECIFICATIONS
In this Section
LINE INTERFACE 6-3
SIGNAL 6-3 LINE CODE 6-3 DATA TYPE 6-3 SIGNAL AMPLITUDE 6-3 LINE CONNECTION 6-3 UN-POWERED PERFORMANCE 6-3
Crosstalk 6-3 Residual output 6-3 Input signal loading 6-3
BUFFER 6-4
MONITOR OUTPUTS (STREAM A AND STREAM B) 6-4
E1DT-ASSY-0058 6-4
E1DT-ASSY-0059 6-4 INPUT IMPEDANCE 6-4 MONITOR OUTPUT IMPEDANCE 6-4 MONITOR OUTPUT LEVEL 6-4 MONITOR OUTPUT SIGNAL PRESENCE INDICATORS 6-4 MONITOR OUTPUT ISOLATION 6-4 INSERTION LOSS 6-4 OUTPUT TO INPUT GAIN VARIATION 6-4 OUTPUT BALANCE ERROR 6-4 NOISE (NO SIGNAL, LOADED INPUT) 6-4 CROSSTALK (STANDARD INPUT) 6-4 MAXIMUM INPUT VOLTAGE 6-4 OUTPUT DRIVE CAPABILITY 6-5 OUTPUT DRIVE ATTENUATION 6-5
UN-POWERED PERFORMANCE 6-5
CROSSTALK 6-5 RESIDUAL OUTPUT 6-5 INPUT SIGNAL LOADING 6-5
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-2
POWER REQUIREMENTS 6-5
VOLTAGE 6-5 CURRENT 6-5 CONNECTOR 6-5 POWER-ON INDICATION 6-5 AC ADAPTERS 6-5
ENVIRONMENTAL 6-6
TEMPERATURE 6-6 RELATIVE HUMIDITY 6-6
PHYSICAL 6-6
DIMENSIONS 6-6 WEIGHT 6-6
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-3
Line Interface
Signal
ITU G.703/G.704, 2,048 kbits/s
Line Code
HDB3
Data Type
Framed or Unframed
Signal Amplitude
Operating: ±3.00V ±10% nominal Absolute Maximum: -5V (lower limit)
+5V (upper limit)
Line Connection
Two RJ-45 connectors hard-wired in parallel. Optional BNC adapter cable available on request.
Line connection supports 120 balanced, 75 unbalanced or monitor connection.
Note that there are no terminating devices in the line interface.
Un-powered performance
Applies to the pass-though connection
Crosstalk
Better than -64dB
Residual output
Better than -35dB
Input signal loading
Less than 0.1dB
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-4
Buffer
Monitor Outputs (Stream A and Stream B)
E1DT-ASSY-0058
RJ-45 connector (Tx pins 1/2 and Rx pins 4/5)
E1DT-ASSY-0059
Two RJ-45 connectors (Tx pins 1/2) compatible with SomerData R2D3 E1/PRI Data Capture card
Input Impedance
1500
Monitor Output Impedance
120 balanced
Monitor Output Level
Unloaded: 2 x Input Level Loaded: Unity Gain
Monitor Output Signal Presence Indicators
LED indicator ±1.2V p-p signal detection threshold
Monitor Output Isolation
Transformer coupled 1500V RMS AC breakdown
Insertion Loss
Less than 0.2dB
Output to Input Gain Variation
Less than 0.1dB
Output Balance Error
-70db (typical)
Noise (no signal, loaded input)
Better than -63dB
Crosstalk (standard input)
Better than -47dB
Maximum Input Voltage
±3.5V
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-5
Output Drive Capability
Greater than 50 metres (120 load, Cat 5 cable)
Output Drive Attenuation
0.2dB per 10 metres
Un-powered Performance
Crosstalk
Better than -64dB
Residual output
Better than -35dB
Input signal loading
Less than 0.1dB
Power Requirements
Voltage
Operating: +6 Volts DC to +12 Volts DC
Absolute Maximum: -0.25V (lower limit)
+15V (upper limit)
Current
Less than 100mA
Connector
Low voltage 2.1mm (centre positive)
Power-on Indication
LED indicator
AC Adapters
UK and European adapters are available as options
E1DT E1/PRI Splitter/Buffer
Installation and Operation 6-6
Environmental
Temperature
0°C to 70°C
Relative Humidity
5% to 95% non-condensing
Physical
Dimensions
55mm x 45mm x 25mm (ABS enclosure)
Weight
50gms
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-1
7. 5BSUPPORT
67BIn this Section
47BWHAT TO DO IF YOU HAVE A PROBLEM 7-1 48BSERVICING, MAINTENANCE AND REPAIRS 7-1 49BIF YOU NEED SUPPORT 7-2 50BSOMERDATA CONTACT INFORMATION 7-2 51BSUPPORT REQUESTS 7-3 52BRETURNS 7-4 53BEND-OF-LIFE DISPOSAL 7-5 54BWASTE OF ELECTRICAL & ELECTRONIC EQUIPMENT (WEEE) 7-5
47BWhat to do if you have a problem
Firstly, please ensure that you have followed the installation, connection and operation instructions in the appropriate User Guide.
Also, check the Troubleshooting section (where appropriate) to eliminate common problems.
48BServicing, Maintenance and Repairs
Please contact your supplier or SomerData for all questions relating to maintenance and repairs.
Any unauthorised attempt to open, modify or otherwise repair the product will invalidate the SomerData warranty and may result in the product being left in an irreparable condition.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-2
49BIf you need Support
For warranty, technical and application support issues, you should initially contact your supplier to check whether your SomerData product is covered by warranty, extended warranty or maintenance contract.
At SomerData, we will make our best efforts to provide prompt and friendly support by phone, fax and e-mail.
To diagnose a problem we will require you to provide a detailed description of the problem in the form of a Fault Report.
50BSomerData Contact Information
Address: Somerdata Limited
1 Riverside Business Park St Annes Road Bristol
BS4 4ED England
Phone: UK 01179-634050
International +44 1173-634050
Fax: UK 01173-302929
International +44 1173-302929
E-Mail: 9Hsupport@somerdata.com
Website: 10Hwww.somerdata.com
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-3
51BSupport Requests
When contacting SomerData for support, please provide as much information as possible about the problem or issue for which you require assistance.
We will be able to deal with your request more efficiently if you provide the following details (where available) in your Fault Report:
Part Number or Model Number
(for example E1DT-ASSY-0059) Serial Number (for example 2008/19/926) Software Version (for example 2.0) Details of any symptoms or error messages Diagnostics information (if available) Sequence of events/actions or other circumstances that
triggered the problem How you are able to identify that there is a problem How you have been able to measure, log or otherwise
display the problem Details of the host PC (if appropriate) including:
operating system; hardware configuration; other
hardware devices (e.g. additional PCI cards); other
software applications (e.g. analysis or processing
programs) that are running at the same time Sample data files (if appropriate)
When we acknowledge your support request, you will be given a Support Tracking Number (STN), which should be quoted in all further correspondence relating to that specific support request.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-4
52BReturns
Please do not return any products to SomerData without first contacting SomerData and obtaining a Return Merchandise Authorisation (RMA) Number.
This will ensure that the processing of any repair or upgrade is handled efficiently and in accordance with any agreed action.
If the SomerData product is under warranty, repairs are free-of charge. If not, there will be a repair charge, which will comprise an initial evaluation fee and quotation, followed by repair and parts (if authority is given to carry-out the repair).
Pack the item in its original packaging. If the original packaging is not available, it must be packed in such a way to avoid transit damage. Damage sustained in transit is not covered under warranty.
Returned goods should be accompanied by documentation that indicates the RMA Number along with a detailed fault report and contact details (name, organisation, phone, fax and e-mail).
Mark the RMA Number on the outside of the package. Ship the item by insured, prepaid carrier to the above address. Items being returned from outside the European Community
must be accompanied by a Commercial Invoice. This should include a description of the goods, value for Customs Purposes and state that the goods are being temporarily returned to the UK for repair. SomerData will not accept liability for UK importation costs resulting from inadequate documentation.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-5
53BEnd-of-Life Disposal
Your SomerData product may be returned to SomerData at the end of its life at the customer's expense under the EU proposed regulations on waste from electrical and electronic equipment legislation, provided that the product is free from radiation or biological contaminants and that no other legislation forbids the return.
54BWaste Electrical & Electronic Equipment (WEEE)
In the UK, Somerdata products may be recycled free of charge at any local authority recycling centre as long as the SomerData logo appears on the product and the following WEEE producer registration number is quoted: WEE/HA0074UR/PRO.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 7-6
This page intentionally blank
E1DT E1/PRI Splitter/Buffer
Installation and Operation 8-1
8. 6BWARRANTY
68BIn this Section
55BINTRODUCTION 8-1 56BWARRANTY: TERMS AND CONDITIONS 8-2
55BIntroduction
This section describes SomerData’s Warranty Terms and
Conditions. Where the SomerData product has been supplied via an
authorised Reseller, the Warranty and Support is between SomerData and its Reseller. Local Warranty and Support arrangements should be agreed between the Reseller and the Customer.
The following information is subject to change without notice.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 8-2
56BWarranty: Terms and Conditions
SomerData warrants all goods supplied by it to be free from defects in material and workmanship, under normal use, care, storage and service, for a maximum period of twelve months from the date of delivery (per Incoterms 2000) by SomerData.
This warranty is limited to the repair or replacement, as SomerData may elect and at an establishment authorised by it, of such items as shall appear to SomerData, upon inspection to have been defective in material or workmanship.
All decisions relating to the validity and processing of Warranty claims shall be at the sole discretion of SomerData.
This warranty does not apply to normal maintenance service or to normal replacement of service goods.
Any claim under this warranty shall expire unless made in writing immediately after the appearance of a claimed defect.
This warranty excludes damage from incorrect installation, unauthorised modification, negligence, misuse or abuse or any item of equipment which has been serviced or worked on by anyone other than SomerData or its authorised representative.
SomerData will repair or replace, at its option, any product purchased from SomerData which, under normal conditions of use and service, proves to be defective in material or workmanship.
No charge will be made for labour or parts with respect to defects covered by this warranty, provided that the work is done by SomerData.
This warranty does not cover expenses incurred in the removal or reinstallation of any SomerData products, whether or not proven defective
Replacement or repairs furnished under this warranty are subject to the same terms and conditions of the original warranty.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 9-1
9. 8BNOTICES
68BIn this Section
55BGENERAL INFORMATION 9-1
DECLARATION OF CONFORMITY 9-2 SOMERDATA AND THE ENVIRONMENT 9-3
69BINTRODUCTION 9-3 70BCURRENT COMPLIANCE ACTIVITIES 9-3 71BRESTRICTION OF USE OF HAZARDOUS SUBSTANCES (ROHS) 9-4
55BGeneral Information
Copyright © 2008 Somerdata Ltd. All Rights Reserved. This publication is protected by copyright and all rights are
reserved. No part of it may be reproduced or transmitted by any means or in any form, without prior consent in writing from SomerData.
The information in this User Guide has been carefully checked and is believed to be accurate. However, SomerData assumes no responsibility for any inaccuracies that may be contained in this publication.
In no event will SomerData be liable for direct, indirect, special, exemplary, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages.
In the interest of continued product development, SomerData reserves the right to make improvements in this publication and the products it describes at any time, without notice or obligation.
All product names mentioned herein are used for identification purposes only, and may be the trademarks or registered trademarks of their respective companies.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 9-2
Declaration of Conformity
Name of Manufacturer:
Somerdata Ltd.
Address of Manufacturer:
Somerdata Ltd 1 Riverside Business Park Bristol
BS4 4ED United Kingdom
Equipment description:
E1 Data Splitter/Buffer
Model:
E1DT-ASSY-0058 E1DT-ASSY-0059
Conforms to the following Product Specifications: Safety: IEC 950 EMC: 89/336/EEC EN55022 Harmonised Standard The product complies with the requirements of the Electromagnetic
Compatibility Directive 89/336/EEC as amended and the Low Voltage Directive 73/23/EEC and carries the CE marking accordingly.
Signed: Position: Technical Director Date: 1 October 2006
E1DT E1/PRI Splitter/Buffer
Installation and Operation 9-3
Somerdata and the Environment
69B
Introduction
SomerData is committed to design and introduce products that conform to applicable environmental legislation and standards.
One of our missions is to integrate environmental stewardship into the business of providing quality products, services, and customer support at the best value.
In order to achieve this, SomerData has established a strategic team to focus on the importance of meeting our environmental obligations in the design, manufacture and support of our products.
We have developed a broad appreciation of the impact of these directives on our entire business model, from technical processes for materials, to finished goods manufacturing.
70B
Current Compliance Activities
The Company’s current environmental compliance commitment has been structured to meet the following European Union directives:
Restriction of use of Hazardous Substances or RoHS
Compliance (EU Directive 2002/95/EC)
Waste Electrical & Electronic Equipment or WEEE
Compliance (EU Directive 2002/96/EC)
Our goal is to meet or exceed compliance obligations of these EU directives.
E1DT E1/PRI Splitter/Buffer
Installation and Operation 9-4
71B
Restriction of use of Hazardous Substances (RoHS)
Somerdata has also established a RoHS qualification process to help ensure that products meet stringent reliability and quality requirements, as well as regulatory compliance requirements.
The maximum allowable hazardous substance at a homogeneous material level under the EU RoHS Directive is shown in the following table.
From 1st July 2006 all SomerData manufactured products use lead-free soldering
Substances
Maximum
Concentration
Values (ppm)
Lead and its compounds
1000
Mercury and its compounds
1000
Hexavalent Chromium (Cr+6)
1000
Cadmium and its compounds
100
PolyBrominated Biphenyls (PBBs)
1000
PolyBrominated Diphenyl Ethers (PBDEs)
1000
E1DT E1/PRI Splitter/Buffer
Installation and Operation 10-1
10. INDEX
Address for SomerData Support ........................................................... 7-2
Available Versions ................................................................................ 2-2
Contact Details ..................................................................................... 7-2
Customer Support ................................................................................ 7-1
Declaration of Conformity ..................................................................... 9-2
E1DT-ASSY-0058 ................................................................................ 2-2
E1DT-ASSY-0058 Signal Connections ................................................. 4-1
Input/Output Connector Pinouts ....................................................... 4-2
Introduction ................................ ................................ ....................... 4-1
E1DT-ASSY-0059 ................................................................................ 2-2
E1DT-ASSY-0059 Signal Connections ................................................. 5-1
Input/Output Connector Pinouts ....................................................... 5-2
Introduction ................................ ................................ ....................... 5-1
End of life disposal ............................................................................... 7-5
General Information .............................................................................. 9-1
Index ................................................................................................... 10-1
Introduction ........................................................................................... 1-1
Notices
Declaration of Conformity ................................................................. 9-2
General Information .......................................................................... 9-1
SomerData and the Environment ..................................................... 9-3
Power Connection ................................................................ ................ 3-1
Power Source ....................................................................................... 3-1
Product Description ....................................................................... 2-1, 4-1
Available Versions ............................................................................ 2-2
E1DT-ASSY-0058 ............................................................................ 2-2
E1DT-ASSY-0059 ............................................................................ 2-2
Introduction ................................ ................................ ....................... 2-1
Returns ................................................................................................. 7-4
SomerData
Contact Details ................................................................................. 7-2
E1DT E1/PRI Splitter/Buffer
Installation and Operation 10-2
SomerData and the Environment ......................................................... 9-3
Specifications ....................................................................................... 6-1
Buffer ................................................................................................ 6-4
Environmental ................................................................................... 6-6
Line Interface .................................................................................... 6-3
Physical ............................................................................................ 6-6
Power Requirements ........................................................................ 6-5
Un-powered Performance................................................................. 6-5
Support
End of life disposal ........................................................................... 7-5
Returns ............................................................................................. 7-4
Support Requests ............................................................................. 7-3
WEEE ............................................................................................... 7-5
SUPPORT ............................................................................................ 7-1
Support Requests ................................................................................. 7-3
User Guides.......................................................................................... 1-1
Warranty ............................................................................................... 8-1
Introduction ................................ ................................ ....................... 8-1
Terms and Conditions ...................................................................... 8-2
WEEE ................................................................................................... 7-5
Loading...