SPECIFICATIONS, MODEL 3215M1
IEPE ACCELEROMETER
SPECIFICATION VALUE UNITS
SENSITIVITY, ±5% 10 mV/g
RANGE, FULL SCALE ±500 gpk
FREQUENCY RANGE, ±5% 1 TO 20000 Hz
RESONANCE FREQUENCY, NOM 50 kHz
DISCHARGE TIME CONSTANT, NOM. 0.5 sec
LOW FREQUENCY -3db POINT, NOM. 0.3 Hz
LOW FREQUENCY -5% POINT 0.9 Hz
LINEARITY [1] ±1 % F.S.
TRANSVERSE SENSITIVITY, MAXIMUM 5 %
OUTPUT IMPEDANCE, NOM. 120 Ω
OUTPUT VOLTAGE BIAS 7.5 to 9.5 VDC
ELECTRICAL NOISE .002 g
SUPPLY CURRENT RANGE [2] 2 to 20 mA
COMPLIANCE (SUPPLY) VOLTAGE RANGE [4] +15 to +24 VDC
OPERATING TEMPERATURE RANGE -60 to +300 °F
SIZE (DIA x HEIGHT) 0.6 x 0.42 inch
WEIGHT 10 grams
MAXIMUM SHOCK 5000 gpk
CONNECTOR, SIDE MOUNTED 10-32 COAXIAL
MATERIAL, HOUSING/CONNECTOR TITANIUM ALLOY
MOUNTING PROVISION THRU HOLE FOR 10-32 THREAD SCREW
ENVIRONMENTAL SEAL HERMETIC
ISOLATION, CASE TO MOUNTING SURFACE, MIN 10 MΩ
[1] Percent of full scale or any lesser designated full scale range, zero-based best fit straight line method.
[2] Power only with Dytran or Dytran approved current source type power unit. Do not supply power without current limiting. You will destroy
the integral electronics. This will void the warranty.
21592 Marilla Street, Chatsworth, California 91311 • Phone: 818.700.7818 • Fax:818.700.7880
www.dytran.com • For permission to reprint this content, please contact info@dytran.com