DYTRAN 3092C DATA SHEET

R
L
PERFORMANCE SPECIFICATION
L
D
MODEL 3092C
HIGH TEMPERATURE, CHARGE MODE ACCELEROMETER
FEATURES:
HIGH TEMPERATURE 10-32 COAXIAL CONNECTO
HIGH TEMPERATURE RANG
Units Minimum Typical Maximum
PHYSICA
Weight grams 42 Mounting #10-32 Connector Type 10-32 coaxial Base Material 17-4 PH
Isolation case ground
PERFORMANC
Sensitivity pC/g 3.5 Frequency Range, ±10% Hz see note 2 5000 Resonance Frequency kHz >40 Transverse Sensitivity % 3 Capacitance pF 80 Non-linearity % 1 Insulation Resistance (Room Temp.) G 300 Insulation Resistance (1000°F) M 1 Insulation Resistance (1200°F) k 75
Actual Size
ENVIRONMENTA
Shock/Vibration g pk 5000/3000 Operating Temperature °F -60 see note 1 Seal hermetic Coefficient of Thermal Sensitivity %/°F 0.01 Magnetic Sensitivity g/G 0.08 Base Strain Sensitivity g/µε 0.06
ACCESSORIES SUPPLIE
none
NOTES
1.) MAXIMUM TEMPERATURE OF OPERATION IS DETERMINED BY THE ABILITY OF THE CHARGE AMPLIFIER TO ACCEPT LOW INSULATION RESISTANCE OF THE SENSOR (SEE GRAPH)
2.) THE LOW FREQUENCY RESPONSE IS DETERMINED BY THE CHARGE AMPLIFIER'S TIME CONSTANT USED IN THE APPLICATION.
3.) EACH INSTRUMENT IS SUPPLIED WITH AN ACCREDITED CALIBRATION CERTIFICATE (ISO 17025 BY A2LA), CALIBRATED AT THE RANGE OF 20Hz TO 10kHz AT ROOM TEMPERATURE.
75 300000000
300GΩ
700 100000000
TYPICALINSULATIONRESISTANCE
1000 1000000
12000 75000
3GΩ
INSULATION RESISTANCE
50kΩ
75 750 1200
REV A ECN 5482 PS3092C ENGLISH VERSION
REV A ECN 5482 PS3092C ENGLISH VERSION
TEMPERATURE (°F)
Loading...