DYTRAN 3086A DATA SHEET

Dynamic Transducers and Systems
21592 Marilla St. • Chatsworth, CA 91311 • Phone 818-700-7818 www.dytran.com • e-mail: info@dytran.com
SPECIFICATIONS, SERIES 3086A/AT
IEPE HIGH SHOCK ACCELEROMETERS
SPECIFICATIONS BY MODEL ISOLATION MODEL RANGE F.S. MAXIMUM SENSITIVITY ELECTRICAL NATURAL CUP SHOCK (NOM)[1] NOISE FREQUENCY RESONANCE (g) (g) (mV/g) (g) (kHz) (kHz)
3086A1/A1T 70,000 100,000 0.05 0.014 100 45 3086A2/A2T 50,000 100,000 0.1 0.007 100 45 3086A3/A3T 20,000 100,000 0.25 0.0028 100 45 3086A4/A4T 10,000 50,000 0.5 0.0014 100 45 3086A5/A5T 5000 50,000 1.0 0.0007 100 45 3086A6/A6T 2500 50,000 2.0 0.0035 100 45
COMMON SPECIFICATIONS
SPECIFICATION VALUE UNITS
DISCHARGE TIME CONSTANT, NOM. 1.0 SECOND
LOW FREQUENCY -3db POINT, NOM. .16 Hz
LOW FREQUENCY -5% POINT .50 Hz
FREQUENCY RESPONSE, ±10% .35 to 10000 Hz
LINEARITY [2] ±1 % F.S.
TRANSVERSE SENSITIVITY, MAXIMUM 3.0 %
OUTPUT IMPEDANCE, NOM. 100 OHMS
OUTPUT VOLTAGE BIAS, NOM. +8.5 VDC
SUPPLY CURRENT RANGE [3] 2 to 20 mA
COMPLIANCE (SUPPLY) VOLTAGE RANGE [4] +18 to +20 VDC
OPERATING TEMPERATURE RANGE -60 to +250 °F
SIZE (HEX x HEIGHT) [4] 3/8 x .64 INCHES
WEIGHT 3.5 GRAMS
CONNECTOR, TOP MOUNTED SOLDER PINS
MATERIAL, HOUSING/CONNECTOR TITANIUM ALLOY
MOUNTING PROVISION, 3086A/3086AT 1/4-28 INTEGRAL STUD/10-32 MOUNTING STUD
ENVIRONMENTAL SEAL HERMETIC
ISOLATION, CASE TO MOUNTING SURFACE, MIN 10 M
RECOMMENDED CABLE: DYTRAN PART NO. 128-6869AXX (XX DENOTES LENGTH IN FEET)
[1] Measured by impacting against calibrated force sensor. NIST traceable. [2] Percent of full scale or any lesser designated full scale range, zero-based best fit straight line method. [3] Power only with Dytran or Dytran approved current source type power unit. Do not supply power without current limiting. You will destroy the integral electronics. This will void the warranty. [4] Height measured from mounting surface to top of connector. Integral mounting studs are .20 in. long.
REV F ECN 7325, 1/19/11 Page 2