DYTRAN 3049E DATA SHEET

MODEL SERIES 3049E Series IEPE ACCELEROMETERS SPECIFICATION VALUE UNITS PHYSICAL
WEIGHT 3049E, 3049E2 3.3 grams 3049E1, 304E3 3.1 grams SIZE, HEX x HEIGHT (all models) .39 x .54 inches MOUNTING PROVISION 3049E, 3049E2 10-32 integral stud x .15 inch 3049E1, 3049E3 adhesive CONNECTOR, TOP MOUNTED 10-32 coaxial MATERIAL, BASE, CAP & CONNECTOR titanium alloy SEISMIC ELEMENT TYPE ceramic, annular shear
PERFORMANCE 3049E 3049E1 3049E2 3049E3
SENSITIVITY, ± 5% [1] 10 10 100 100 mV/g RANGE F.S. FOR ± 5 VOLTS OUTPUT ± 500 ±500 ±50 ±50 g FREQUENCY RANGE, ± 5% (all models) 1 to 10,000 Hz RESONANT FREQUENCY, NOM. (all models) 35 kHz EQUIVALENT ELECTRICAL NOISE .002 .002 .001 .001 grms BASE STRAIN SENSITIVITY .004 .004 .004 .004 eq g/µe LINEARITY [2] (all models) ±2 % F.S. TRANSVERSE SENSITIVITY, MAX. (all models) 5 %
ENVIRONMENTAL 3049E 3049E1 3049E2 3049E3
MAXIMUM VIBRATION 600 600 200 200 g pk MAXIMUM SHOCK (all models) 5000 g pk TEMPERATURE RANGE min -60 -60 -60 -60 °F max 250 250 212 212 °F SEAL, HERMETIC (all models) glass-to-metal/welded COEFFICIENT OF THERMAL SENSITIVITY .06 %°F
ELECTRICAL
SUPPLY CURRENT [3] 2 to 20 mA COMPLIANCE VOLTAGE RANGE +18 to +30 Volts OUTPUT IMPEDANCE, TYP. 100 BIAS VOLTAGE. +11 to +13 Vdc DISCHARGE TIME CONSTANT, MIN. 0.5 Sec OUTPUT SIGNAL POLARITY positive FOR ACCELERATION TOWARD TOP ELECTRICAL ISOLATION, MIN 10 M CASE GROUND TO MOUNTING SURFACE
Accessories supplied: none
[1] Measured at 100 Hz, 1 grms per ISA RP 37.2. [2] Measured using zero-based best straight line method, % of F.S. or any lesser range. [3] Do not apply power to this device without current limiting, 20 mA MAX. To do so will destroy the integral IC
amplifier.
REV C ECN 6700 04/14/10