
TECHNICAL SPECIFICATION
SIDE ELEVATIONFRONT ELEVATION
Fixing
locations
(4)
Water
entry point
"
1115⁄
1
"
⁄
mm)
(64
2
2
mm)
(372
"
8
⁄
5
14
16
(50.8
(303
"
2
mm)
1
mm)
3
"
⁄
(35
8
mm)
Fixing
locations
(4)
"
7
mm)
(159
"
4
⁄
1
6
Sink/worktop thickness
1
"
/
Max 2
Min 3/
mm)
(266
16
⁄
(57mm)
4
"
(3.5mm)
16
1
"
11
(286
⁄
mm)
4
Distance from
the aerator to the
end of the tap
2
(52.2
1
"
⁄
16
mm)
mm)
(631.5
"
8
/
7
mm) / Min 24
(835.5
"
8
/
7
Max 32
10
Rear cable
entry point
Fixing
locations
(4)
FLOOR
Tap dimensions
WD04: Height 61/
Motor bucket dimensions
WD04: Height 107/
"
(159mm), Width 11
4
"
(266mm), Width 5
16
9
"
(142
⁄
5
16
15
"
/
(303mm), Depth 11
16
9
"
/
(142mm), Depth 7
16
mm)
1
"
/
(286mm)
4
7
"
/
(189mm)
16
Fixing
locations
(4)
All dimensions shown
in inches (+/-
3
"
/
)
16
Minimum clearance
Z 4" (100mm) clearance from floor. ADA requires 9" (228mm) toe clearance.
7
"
7
⁄
mm)
(189
16

TECHNICAL SPECIFICATION
FRONT ELEVATION SIDE ELEVATION
21⁄
(64mm)
2
2"
mm)
(50.8
mm)
mm)
(309
"
16
⁄
3
12
3
"
1
⁄
mm)
(35
8
Sink/worktop thickness
"
Max 21/
mm)
(372
"
8
⁄
5
14
Fixing
locations
(4)
Min 3/
(57mm)
4
"
(3.5mm)
16
Fixing
locations
(4)
15
"
⁄
(303
11
16
1
"
⁄
mm)
(286
11
4
Distance from
the aerator to the
end of the tap
2
(52.2
1
"
⁄
16
mm)
mm)
(631.5
"
8
/
7
mm) / Min 24
(835.5
"
8
/
7
Max 32
Water
entry point
Fixing
locations
(4)
FLOOR
Tap dimensions
WD05: He igh t 123/
Motor bucket dimensions
WD05: Heigh t 107/
"
(309mm), Width 11
16
"
(266mm), Width 5
16
9
"
5
⁄
(142
16
15
"
/
(303mm), Depth 11
16
9
"
/
(142mm), Depth 7
16
mm)
1
7
"
/
16
mm)
(266
"
16
⁄
7
10
"
/
(286mm)
4
(189mm)
Rear cable
entry point
Fixing
locations
(4)
All dimensions shown
in inches (+/-
3
"
/
)
16
Minimum clearance
Z 4" (100mm) clearance from floor. ADA requires 9" (228mm) toe clearance.
7
"
(189
⁄
7
mm)
16

<2
"
(<50mm)
6
"
(153mm)13
1
⁄
2
"
(342
mm)
1115⁄
16
"
(303
mm)
10
11
⁄
16
"
(272
mm)
10
1
⁄
4
"
(260
mm)
12
1
⁄
4
"
(312
mm)
10
3
⁄
4
"
(272
mm)
13⁄
8
"
(34mm)
711⁄
16
"
(196
mm)
7
5
⁄
8
"
(194
mm)24
1
⁄
2
"
(623
mm)
13
1
⁄
2
"
(343
mm)
14
9
⁄
16
"
(370
mm)
3
5
⁄
8
"
6
7
⁄
8
"
(175mm)
1
1
⁄
4
"
1
5
⁄
8
"
(94mm)
(32mm)
(42mm)
23⁄
4
"
(71
mm)
2
1
⁄
16
"
(52.2
mm)
3
3
⁄
4
"
(95.4
mm)
2" (50.8
mm)
1
9
⁄
16
"
(40
mm)
23⁄
8
"
(60
mm)
6
"
(153mm)13
1
⁄
2
"
(342
mm)
1115⁄
16
"
(303
mm)
10
11
⁄
16
"
(272
mm)
10
1
⁄
4
"
(260
mm)
10
3
⁄
4
"
(272
mm)
13⁄
8
"
(34mm)
14
9
⁄
16
"
(370
mm)
3
5
⁄
8
"
6
7
⁄
8
"
(175mm)
1
1
⁄
4
"
1
5
⁄
8
"
(94mm)
(32mm)
(42mm)
2
1
⁄
16
"
mm)
3
3
⁄
4
"
(95.4
mm)
2" (50.8
mm)
1
9
⁄
16
"
(40
mm)
23⁄
8
"
(60
mm)
TECHNICAL SPECIFICATION
Distance from
the aerator to the
end of the tap
3
"
/
(5mm)
16
diameter hole
FRONT ELEVATIONSIDE ELEVATION
FLOOR
Tap dimensions
WD06: L eng th 121/
Motor bucket dimensions
WD06: H eight 107/
"
(312mm), Width 11
4
"
16
(266mm), Width 5
Water
entry
point
Cable
entry
point
15
"
/
(303mm)
16
9
"
/
(142mm), Depth 7
16
Fixing
7
"
/
(189mm)
16
Minimum clearance
Suggested installation height 379/
depending on height of sink. Check installation guide for further details.
locations
(4)
"
(955mm) from finished floor to center of tap,
16

TECHNICAL SPECIFICATION
WD06 Wall installation
The Dyson Airblade Wash+Dry hand dryer is designed
so that the motor unit is located behind the stud wall within
a metal enclosure which is supplied with the Dyson Airblade
Wash+Dry hand dr yer (Fig.1). The vertical wall studs must
be constructed so as to allow the metal enclosure to be fit ted
between them (Fig.2). One of the horizontal wall studs must
be fitted a) so it holds the main weight of the metal duct and
the unit, and b) so it is in the correct position for the tap stem.
For complete instructions, please refer to the printed
installation guide supplied with the machine.
It’s also available online at www.dyson.com/docs
Fi g.1
Fig.2
Fig.3 Fig.4
Install
plasterboard.
Install Dyson
Airblade
Wash+Dry
hand dryer.

TECHNICAL SPECIFICATION
Electrical
Input voltage: Low Voltage = 100-110V, High Voltage = 200-240V
Frequency: Low Voltage = 50- 60Hz, subject to voltage
(120V at 60Hz; 100-110V at 50Hz), High Voltage = 50-60Hz
Motor specification: 1000W digital brushless motor
Motor Speed: 81,000 rpm
Motor Switching rate: 5,400 per second
Motor type: Dyson digital motor – V4 brushless DC Motor
Amp: Recommended dedicated 15 amp circuit,
Low Voltage= 9.09 amps at 110V, High Voltage = 6.36 amps at 220V
Operating temperature range: 0°-40°C, 32°-104°F
Heater type: None
Standby power consumption: Less than 0.5 W
Construction
Tap construction: Stainless steel (brushed)
Lead free
Under counter motor bucket: Molded ABS (main unit) also uses
polycarbonate and polypropylene
Exterior screw type: Torx T15
Water ingress protection rating to IP35
Filter
Double-life HEPA filter (glass fiber and fleece prelayer)
Capture 99.97% of particles the size of bacteria
as small as 0.3 microns from the washroom air.
Operation
Touch-free infra-red activation
Hand dry time measurement: 14 seconds*
Operation lock-out period: 30 seconds
Airspeed at apertures: Low Voltage = 331 mph (533 km/h),
High Voltage = 341 mph (549 km/h)
Maximum altitude: Low Voltage = 2,700 meters (8,858 feet),
High Voltage = 2,300 meters (7,546 feet)
Rated operating noise power: Low Voltage = 80 db(A) for WD04-06,
High Voltage = 80 db(A) for WD06, 81 db(A) for WD04-05
Sound pressure level @ 2m: 66 dB(A)
†
Operation airflow: Up to 5.5 gallons/sec (21 liters/sec)
Water operation
Water flow rate: 0.5 gallons/min (1.9 liters/min) low flow fitted aerator,
1.0 gallons/min (3.8 liters/min) with aerator supplied with product
Water temperature control: Thermostatic mixer recommended (not supplied)
Water pressure required: 14.5-116 psi
Tap power supply: Mains supply
Equipped with automatic flush – every 24 hours for 60 seconds, after last use.
Sink specification
The Dyson Airblade Wash+Dry hand dryer is compatible with most
sink types. Ensure plugs are not installed in the sinks and avoid
inserts with embedded plugs (e.g. ones that swivel or elevate).
Using a specially designed test method, Dyson engineers evaluated the user
experience of a wide range of sink types when used with the Dyson Airblade
Wash+Dry hand dr yer. For fur ther details on our recommended sinks,
please see the pre-installation guide on our website: dyson.com/docs
We recommend avoiding sinks with the following geometric characteristics:
Flat bases immediately surrounding the drain hole,
nominally within a 2
5
"
(60mm) radius.
/
16
Sloping back and front wall transitions in relation to the base of the sink.
See our pre-installation guide for further details: dyson.com/docs
Sink dimensions:
All sink measurements are internal unless stated otherwise.
Minimum width of sink: 15" (380mm), Front to back – Minimum: 13" (330mm)
Minimum depth of sink: 5" (127m m)
Maximum depth of sink for WD05 only: 8" (200mm)
(External measurement of vessel sink)
Sink materials: Sinks with highly polished surfaces should be avoided,
e.g. reflective chrome. Porcelain or brushed metal is ideal. When multiple
taps are installed side-by-side, tap centers should be a minimum
7
"
(580mm) apart.
/
of 22
8
Standard warranty
5 year par ts, 5 year limited labor warranty.
Product range
Product range
WD04 Short WD05 Tall WD06 Wall
Part number/SK U
Low Voltage: 247659-01
High Vo ltag e: 247 90 8-01
Part number/SK U
Low Voltage: 247663-01
High Vo ltag e: 247 910-01
Part number/SK U
Low Voltage: 247669-01
High Vo ltag e: 247 915- 01
Accreditations
Carbon Tru st
HACCP International
Quiet Mark
WD04 Short and WD06 Wall are ADA compliant
Logistics
Net weight: WD04 = 9.39 lb; WD05 = 10.01 lb; WD06 = 20.97 lb
Packaged weight: WD04 = 14.90 lb; WD05 = 16.27 lb; WD06 = 30.09 lb
Packaged dimensions: WD04 = H 117/
"
(291mm); WD05 = H 17" (434mm) × W 10
D 111/
2
(288mm)
; WD06 = H 24" (610mm) × W 143/
"
(303mm) × W 11
8
"
(375mm) × D 11
4
1
"
(284mm) ×
/
8
7
"
(275mm) × D 11
/
8
7
" (302mm)
/
8
5
"
/
16
UPC Barcodes: Low Voltage/ WD04: 885609014104, WD05: 8 85 60 9014111,
WD06: 885609014128; High Voltage/ WD04: 885609014074,
WD05: 885609014081, WD06: 885609014098
* Dry time determined using Dyson t est method 769 base d on NSF P335 to a me asurement
of 0.1g residual moisture.
†
Sound p ressure measured at 6. 56 feet (2 meter s) distance, in a semi-ane choic chamber.

Further documents are
available online to download:
Pre-installation guide
Installation guide
Dyson Airblade Wash+Dry
hand dryer brochure
Cleaning guide
CAD drawings
Installation videos
The Car bon label is a tr ademark of th e Carbon Trus t. HACCP Inte rnational n on-food
certification mark is the registered trademark of HACCP International. HACCP International
have ce rtified D yson produ cts base d on their reco mmended in stallatio n and operati ng
condit ions. Licen sed by Dyso n. Quiet Mar k is a trademar k of the Noise A batement S ociety.
For further information, please contact Dyson:
1 -888- 397 -6 622 | airbladeinfo@dyson.com | www.dyson.com
6798 066 11.07.18 ©2 018 DYSO N