DF654
DF654
Fast Recovery Diode
Replaces March 1998 version, DS4214-3.5 DS4214-4.0 January 2000
APPLICATIONS
■ Induction Heating
■ A.C. Motor Drives
■ Inverters And Choppers
■ Welding
■ High Frequency Rectification
■ UPS
FEATURES
■ Double Side Cooling
■ High Surge Capability
■ Low Recovery Charge
VOLTAGE RATINGS
Type Number Repetitive Peak
Reverse Voltage
V
RRM
V
DF654 35
DF654 34
DF654 32
DF654 30
3500
3400
3200
3000
Conditions
= V
V
RSM
RRM
+ 100V
KEY PARAMETERS
V
I
F(AV)
I
FSM
Q
t
rr
RRM
r
3500V
675A
6000A
900µC
6.5µs
Lower voltage grades available.
See Package Details for further information.
CURRENT RATINGS
Symbol Parameter Conditions
Double Side Cooled
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Single Side Cooled (Anode side)
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Half wave resistive load, T
= 65oC 1060 A
T
case
T
= 65oC 960 A
case
Half wave resistive load, T
T
= 65oC 690 A
case
T
= 65oC 600 A
case
Outline type code: M779b.
= 65oC 675 A
case
= 65oC 440 A
case
UnitsMax.
1/7
DF654
SURGE RATINGS
ParameterSymbol
FSM
FSM
Surge (non-repetitive) forward currentI
Surge (non-repetitive) forward currentI
THERMAL AND MECHANICAL DATA
Symbol Parameter
R
th(j-c)
th(c-h)
T
T
stg
Thermal resistance - junction to case
Thermal resistance - case to heatsinkR
Virtual junction temperature
vj
Storage temperature range -55 150
Conditions
Max. Units
6.0 kA
10ms half sine; with 0% V
RRM, Tj
= 150oC
180 x 10
4.8 kA
10ms half sine; with 50% V
RRM, Tj
= 150oC
115 x 10
Conditions Max. Units
Double side cooled
dc
Min.
- 0.045
Single side cooled
- 0.095
0.01
-
- 0.02
Clamping force 10kN
with mounting compound
Cathode dc
Double side
Single side
Forward (conducting) - 150
3
A2sI2t for fusingI2t
3
A2sI2t for fusingI2t
o
C/W
o
C/W- 0.086Anode dc
o
C/W
o
C/W
o
C/W
o
C
o
C
11.09.0Clamping force-
CHARACTERISTICS
Symbol Typ. Units
V
FM
I
RRM
t
rr
Q
RA1
I
RM
Forward voltage
Peak reverse current
Reverse recovery time
Recovered charge (50% chord)
Reverse recovery current
K Soft factor
V
TO
r
T
V
FRM
Threshold voltage
Slope resistance
Forward recovery voltage di/dt = 1000A/µs, Tj = 125oC--V
Parameter
Conditions Max.
At 1500A peak, T
At V
, T
RRM
= 150oC-mA
case
= 25oC - 2.4 V
case
60
- 6.5
= 1000A, diRR/dt = 100A/µs
I
F
T
= 150oC, VR = 100V
case
- 900 µC
- 300 A
---
At Tvj = 150oC - 1.1 V
At Tvj = 150oC - 0.9 mΩ
kN
µs
2/7
DF654
DEFINITION OF K FACTOR AND Q
Q
= 0.5x IRR(t1 + t2)
RA1
dIR/dt
0.5x I
t
1
RR
I
RR
k = t
t
2
1/t2
CURVES
3000
2500
- (A)
F
Measured under pulse conditions
RA1
τ
2000
Tj = 150˚C
1500
Instantaneous forward current I
1000
Tj = 25˚C
500
1.5 2.0 2.5 3.0 3.5
Instantaneous forward voltage V
- (V)
F
Fig.1 Maximum (limit) forward characteristics
3/7