DYNEX DF45116, DF45114, DF45112, DF45110, DF45108 Datasheet

...
DF451
DF451
Fast Recovery Diode
Replaces March 1999 version, DS4142-4.0 DS4143-5.0 January 2000
FEATURES
Double Side Cooling
High Surge Capability
Low Recovery Charge
Applications
Induction Heating
Inverters And Choppers
Welding
High Frequency Rectification
UPS
Voltage Ratings
Type Number Repetitive Peak
Reverse Voltage
V
RRM
V
DF451 16 DF451 14 DF451 12 DF451 10 DF451 08 DF451 06
1600 1400 1200 1000
800 600
Conditions
= V
V
RSM
RRM
+ 100V
KEY PARAMETERS
V
RRM
I
F(AV)
I
FSM
Q
r
t
rr
Outline type code: M771.
See Package Details for further information.
1600V
295A
3500A
25µC
1.22µs
CURRENT RATINGS
Symbol Parameter Conditions
Double Side Cooled
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Single Side Cooled (Anode side)
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Half wave resistive load, T
= 65oC 543 A
T
case
T
= 65oC 391 A
case
Half wave resistive load, T
T
= 65oC 348 A
case
T
= 65oC 285 A
case
= 65oC 295 A
case
= 65oC 220 A
case
UnitsMax.
1/8
DF451
SURGE RATINGS
ParameterSymbol
FSM
FSM
Surge (non-repetitive) forward currentI
Surge (non-repetitive) forward currentI
THERMAL AND MECHANICAL DATA
Symbol
R
th(j-c)
R
th(c-h)
Thermal resistance - junction to case
Thermal resistance - case to heatsink
Parameter
Conditions
10ms half sine; with 0% V
10ms half sine; with 50% V
Conditions Max. Units
Double side cooled
Single side cooled
Clamping force 5.0kN with mounting compound
= 150oC
RRM, Tj
= 150oC
RRM, Tj
dc Anode dc Cathode dc
Double side Single side
Max. Units
3.5 kA
61.25 x 103A2sI2t for fusingI2t
2.8 kA
39.2 x 103A2sI2t for fusingI2t
-
- 0.07
o
C/W
o
C/W- 0.133
- 0.147oC/W
0.02
-
o
C/W
- 0.02oC/W
T
T
stg
Virtual junction temperature
vj
Storage temperature range –55 150
Forward (conducting) - 150
5.54.5Clamping force-
CHARACTERISTICS
Symbol Typ. Units
V
FM
I
RRM
t
rr
Q
RA1
I
RM
K
V
TO
Forward voltage
Peak reverse current Reverse recovery time
Recovered charge (50% chord) Reverse recovery current
Soft factor
Threshold voltage
Parameter
Conditions Max.
At 600A peak, T At V
, T
RRM
case
= 500A, diRR/dt = -80A/µs
I
F
T
= 125oC, VR = 100V
case
= 25oC - 2.65 V
case
= 125oC-mA
1.22
100
-
-25µC
-40A
1.7 - -
At Tvj = 125oC - 1.6 V
o
o
kN
µs
C C
2/8
r
T
V
FRM
Slope resistance
At Tvj = 125oC - 1.5 m
Forward recovery voltage di/dt = 1000A/µs, Tj = 125oC-40V
DF451
DEFINITION OF K FACTOR AND Q
CURVES
3000
2500
- (A)
F
Measured under pulse conditions
RA1
dIR/dt
0.5x I
Q
= 0.5x IRR(t1 + t2)
RA1
k = t
t
t
1
2
RR
I
RR
1/t2
τ
2000
Tj = 150˚C
1500
Instantaneous forward current, I
1000
500
2.0 3.0 4.0 5.0 6.0 Instantaneous forward voltage, V
Tj = 25˚C
- (V)
F
Fig.1 Maximum (limit) forward characteristics
3/8