DCR1375SBA
DCR1375SBA
Phase Control Thyristor
Advance Information
Replaces October 2000 version, DS4654-4.0 DS4654-5.0 July 2001
FEATURES
■ Double Side Cooling
■ High Surge Capability
■ Low Turn-on Losses
APPLICATIONS
■ High Voltage Power Converters
■ High Voltage Power Supplies
■ Motor Control
VOLTAGE RATINGS
Type Number Repetitive Peak
Voltages
V
DRM VRRM
V
DCR1375SBA28
DCR1375SBA27
DCR1375SBA26
DCR1375SBA25
DCR1375SBA24
Lower voltage grades available.
2800
2700
2600
2500
2400
Conditions
Tvj = 0˚ to 125˚C,
I
= I
RRM
, V
& V
& V
RRM tp
= 150mA,
= 10ms,
=
RSM
+ 100V
RRM
DRM
V
DRM
V
DSM
V
DRM
respectively
KEY PARAMETERS
V
DRM
I
T(AV)
I
TSM
dVdt 1000V/
dI/dt 500A/
2800V
2004A
35000A
µs
µs
Outline type code: MU140.
See Package Details for further information.
ORDERING INFORMATION
When ordering, select the required part number shown in the
Voltage Ratings selection table.
For example:
DCR1375SBA26
Note: Please use the complete part number when ordering
and quote this number in any future correspondance relating
to your order.
www.dynexsemi.com
Fig.1 Package outline
1/8
DCR1375SBA
CURRENT RATINGS
T
= 60˚C unless stated otherwise.
case
Symbol Parameter Conditions
Double Side Cooled
I
T(AV)
I
T(RMS)
I
Mean on-state current
RMS value
T
Continuous (direct) on-state current
Half wave resistive load 2004 A
Single Side Cooled (Anode side)
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Half wave resistive load 1491 A
CURRENT RATINGS
T
= 80˚C unless stated otherwise.
case
Symbol Parameter Conditions
Double Side Cooled
UnitsMax.
- 3148 A
- 2846 A
- 2342 A
- 2009 A
UnitsMax.
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Single Side Cooled (Anode side)
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Half wave resistive load 1575 A
- 2475 A
- 2200 A
Half wave resistive load 1150 A
- 1805 A
- 1520 A
2/8
www.dynexsemi.com
SURGE RATINGS
DCR1375SBA
Symbol
I
TSM
2
tI
I
I
TSM
I2t
Surge (non-repetitive) on-state current
2
t for fusing
Surge (non-repetitive) on-state current
2
I
t for fusing 6.125 x 106A2s
Parameter
THERMAL AND MECHANICAL DATA
Symbol
R
th(j-c)
R
th(c-h)
Thermal resistance - junction to case
Thermal resistance - case to heatsink
Parameter
Conditions
10ms half sine; T
VR = 50% V
RRM
10ms half sine; T
VR = 0
Conditions Min. Max. Units
Double side cooled
Single side cooled
Clamping force 40kN
with mounting compound
= 125oC
case
- 1/4 sine
= 125oC
case
dc
Cathode dc
Double side
Single side
Max. Units
28 kA
6
3.92 x 10
A2s
35 kA
o
- 0.013
C/W
o
C/W- 0.021Anode dc
- 0.034oC/W
0.003
-
- 0.006
o
C/W
o
C/W
On-state (conducting) - 135
T
vj
T
stg
-
Virtual junction temperature
Storage temperature range
Clamping force
Reverse (blocking)
-
125
–55 125
36.0 44.0 kN
o
C
o
C
o
C
www.dynexsemi.com
3/8