DCR1374SBA
DCR1374SBA
Phase Control Thyristor
Replaces February 2001 version, DS4597-5.1 DS4597-5.2 July 2001
FEATURES
■ Double Side Cooling
■ High Surge Capability
■ Low Turn-on Losses
APPLICATIONS
■ High Voltage Power Converters
■ DC Motor Control
■ High Voltage Power Supplies
VOLTAGE RATINGS
Part and Ordering
Number
DCR1374SBA18
DCR1374SBA16
DCR1374SBA14
DCR1374SBA12
DCR1374SBA10
DCR1374SBA08
Lower voltage grades available.
Repetitive Peak
Voltages
V
and V
DRM
V
1800
1600
1400
1200
1000
800
DRM
Conditions
T
= 0˚ to 125˚C,
vj
I
= I
RRM
, V
& V
& V
RRM tp
= 150mA,
RSM
RRM
DRM
V
DRM
V
DSM
V
DRM
respectively
= 10ms,
=
+ 100V
KEY PARAMETERS
V
I
T(AV)
I
TSM
DRM
(max) 2694A
(max) 50000A
1800V
dV/dt 1000V/
dI/dt 1000A/
Outline type code: MU140
(See Package Details for further information)
Fig. 1 Package outline
µs
µs
ORDERING INFORMATION
When ordering, select the required part number shown in the
Voltage Ratings selection table.
For example:
DCR1374SBA16
Note: Please use the complete part number when ordering and
quote this number in any future correspondance relating to your
order.
www.dynexsemi.com
1/9
DCR1374SBA
CURRENT RATINGS
T
= 60˚C unless stated otherwise.
case
Symbol
Double Side Cooled
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Single Side Cooled
I
T(AV)
I
T(RMS)
I
T
T
= 80˚C unless stated otherwise.
case
Mean on-state current
RMS value
Continuous (direct) on-state current
Symbol
Double Side Cooled
Parameter
Parameter
Test Conditions
Half wave resistive load
Half wave resistive load
Test Conditions
Max.
2694
-
-
4230
3682
1965
-
-
3086
2534
Max.
Units
A
A
A
A
A
A
Units
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Single Side Cooled
I
T(AV)
I
T(RMS)
I
T
Mean on-state current
RMS value
Continuous (direct) on-state current
Half wave resistive load
Half wave resistive load
2084
-
-
3275
2770
1500
-
-
2350
1875
A
A
A
A
A
A
2/9
www.dynexsemi.com
SURGE RATINGS
DCR1374SBA
Symbol
I
TSM
I2t
I
TSM
I2t
Surge (non-repetitive) on-state current
2
t for fusing
I
Surge (non-repetitive) on-state current
2
t for fusing
I
Parameter
THERMAL AND MECHANICAL RATINGS
Symbol
R
th(j-c)
R
th(c-h)
Thermal resistance - junction to case
Thermal resistance - case to heatsink
Parameter
Test Conditions
10ms half sine, T
= 50% V
V
R
10ms half sine, T
V
R
case
- 1/4 sine
RRM
case
= 0
= 125˚C
= 125˚C
Test Conditions
Double side cooled DC
Single side cooled Anode DC
Cathode DC
Clamping force 40.0kN Double side
(with mounting compound) Single side
Min.
-
-
-
-
-
Max.
40
8 x 10
50
12.5 x 10
Max.
0.013
0.021
0.034
0.003
0.006
Units
kA
2
6
s
A
kA
2
6
s
A
Units
˚CW
˚CW
˚CW
˚CW
˚CW
T
vj
Virtual junction temperature
On-state (conducting)
Reverse (blocking)
T
stg
F
m
Storage temperature range
Clamping force
-
-
–55
36.0
135
125
125
44.0
˚C
˚C
˚C
kN
www.dynexsemi.com
3/9