Heatsinks
HEATSINKS
Power Assemblies
DS5404-1.0 November 2000
The current range of heatsinks is illustrated with a brief
resumé of their characteristics. The products available are
intended for use with all our power semiconductors - from
the small stud base through to large disc devices and
modules.
AIR COOLED HEATSINKS
All dimensions shown in mm unless stated otherwise.
0.5
0.48
0.46
0.44
0.42
0.4
0.38
0.36
0.34
THERMAL RESISTANCE (˚C/W)
0.32
0.3
125 175 225 275 325 375
HEATSINK LENGTH (mm)
200W
0.15
0.145
0.14
0.135
0.13
THERMAL RESISTANCE (˚C/W)
0.125
0.12
125 165 205 245 285
HEATSINK LENGTH (mm)
200W
All heatsinks are suitable for Natural Air Cooling (AN) and
Forced Air Cooling (FC). In addition to a vast experience of
AN and FC cooling methods we also have many years
experience in liquid and phase change cooling.
A range of coolers for 17mm to 100mm silicon diameter
devices is available, as is a range of associated clamps.
77.5
M8 slots
Cross sectional area (cm
Heatsink profile: EDForced air (5m/s)Air natural
27
175
Weight kg/m: 141.2
2
): 52.3
0.44
0.42
0.4
0.38
0.36
0.34
THERMAL RESISTANCE (˚C/W)
0.32
0.3
125 175 225 275 325 375
HEATSINK LENGTH (mm)
200 W
0.1
0.095
0.09
0.085
0.08
THERMAL RESISTANCE (˚C/W)
0.075
125 175 225 275 325 375
HEATSINK LENGTH (mm)
200W
120
222 ± 1
50
Cross sectional area (cm2): 124.08
Weight kg/m: 31
Heatsink profile: EMForced air (5m/s)Air natural
M6 slot
M8 slots
www.dynexsemi.com
1/5
Heatsinks
Notes:
1.Thermal ratings are given per
heatsink.
2.Comprehensive data is available
for all our heatsinks to support all
design applications.
3.Black anodising is available on all
air cooled heatsinks for surface
protection and enhanced
performance.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
THERMAL RESISTANCE (˚C/W)
0.7
0.6
60 80 100120140160180200220
WATER COOLED HEATSINKS
Water cooled heatsinks are
designed for use in high
current, high power
assemblies such as single,
0.04
three or six phase bridges or
A.C. controllers. Complete
bridges of up to six devices
may be constructed.
80W
HEATSINK LENGTH (mm)
90
Cross sectional area (cm2): 26.21
Weight kg/m: 7.1
Heatsink profile: EHAir natural
2 heatsinks for double side
cooling, thermal resistance
heatsink surface to water
inlet.
M6 slots
67
M8 slot
All dimensions shown in mm
unless stated otherwise.
0.035
0.03
0.025
0.02
THERMAL RESISTANCE (˚C/W)
0.015
12345678910
0.03
0.028
0.026
0.024
0.022
0.02
0.018
0.016
0.014
THERMAL RESISTANCE (˚C/W)
0.012
12345678910
Note:
1. For details of water connections, please contact factory.
WATER FLOW (L/m)
WATER FLOW (L/m)
Type code: D
Type code: K
2/5
www.dynexsemi.com