Dynavac G-4RB Service Manual

G-4RB 4RB 210

Performance curve for Vacuum pump
Performance curve for Compressor
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
mbar
mbar
total pressure difference (vacuum)
p
total pressure difference (vacuum)
p
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
total pressure difference (gauge)
total pressure difference (gauge)
mbar
p
mbar
p
temperature rise T (in K)
on the air handled
mbar
The performance curves are based on air at a temperature of 15 °C and an atmospheric pressure of 1013 mbar with a tolerance of +/- 10 %. The total pressure differences are valid for suction and ambient temperatures up to 25 °C. For other conditions please confer with us.
p
total pressure difference (vacuum)
temperature rise T (in K)
on the air handled
total pressure difference (gauge)
Each G-4RB type can be applied both as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 55 as well as approbated for UL and CSA.
Technical data sheet Edition 04/2010 En
p
mbar
Selection and ordering data
Type 4RB210
Curve No.
Order No.
Fre­quency
Rated power
Input voltage
Input current
Permissible total differential pressure ²)
Sound pressure level ³)
Weight ca.
kW
Hz
3~ 50/60 Hz IP55 isulation material class F 1)
B 140 4RB210-0AH16-7 50 0.55 200D ... 240D 345Y...415Y 2.8D 1.6Y -230 290 57 16 B 141 4RB210-0AH16-7 60 0.63 220D ... 275D 380Y...480Y 3.0D 1.7Y -270 320 62 16
1~ 50/60 Hz IP55 with attached condenser for continuous operation
B 140s 4RB 210-0AV75-7 50 0.55 115 230 13.0 3.1 -230 290 57 18 B 141s 4RB 210-0AV75-7 60 0.63 115 230 14.2 7.1 -260 310 62 18
V
A
Vacuum mbar
Compressor mbar
dB(A)
kg
All G-4RB achieve the standards and norms of the low voltage directive (LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004, electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6.
1) For standard UL for ELECTRIC MOTOR UL 1004-1.
2) Relief-valve are available for limiting differential pressure.
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured at a distance of 1 m. The pump is throttled to an average suction pressure, a hose is connected to the discharge side (compressor) / suction side
(vacuum pump), but is not tted with relief valves.
Other voltage ranges
□ □
50Hz
3
~
185...225 V D/320...390 V Y 200...240 V D/345...415 V Y H 1
200...240 V D/345...415 V Y 200...275 V D/380...480 V Y H 6
345...415 V D 380...480 V D H 7
500 V D 575VD C 5
Machines according to the ATEX norm 94/4 EG are available for the whole performance range. Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
1
~
100 / 200 V 100 / 200 V V 4
115 / 230 V 115 / 230 V V 5
230V --- A 1
Further voltage range on request; please quote in plain text.
The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and temperature class F.
For the three phase machines the tolerances are +/- 10 % for xed voltage and
+/- 5 % for voltage range. The single phase machines are designed with a +/- 5 % tolerances. If only 90 % of the maxium allowed pressure will be used for the continuousoperating then the allowed voltage range add to +/- 10 %. For all single and three phase machines which designed according to the UL and CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp. + 6 %. The frequency tolerance is maximum +/- 2 %.
60Hz
↑↑
Changes in particular the quoted performance curve, datas and weights without prior notice. The gures are without obligations.
DYNAPUMPS
DYNAPUMPS Sydney-Melbourne-Brisbane-Perth Phone: 1300 788 579 E-mail:sales@dynapumps.com.au

G-4RB 4RB 220

Performance curve for Vacuum pump
Performance curve for Compressor
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
mbar
mbar
total pressure difference (vacuum)
p
total pressure difference (vacuum)
p
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
total pressure difference (gauge)
total pressure difference (gauge)
mbar
p
mbar
p
temperature rise T (in K)
on the air handled
total pressure difference (vacuum)
p
mbar
The performance curves are based on air at a temperature of 15 °C and an atmospheric pressure of 1013 mbar with a tolerance of +/- 10 %. The total pressure differences are valid for suction and ambient temperatures up to 25 °C. For other conditions please confer with us.
temperature rise T (in K)
on the air handled
mbar
total pressure difference (gauge)
Each G-4RB type can be applied both as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 55 as well as approbated for UL and CSA.
Technical data sheet Edition 04/2010 En
p
Selection and ordering data
Type 4RB220
Curve No.
Order No.
Fre­quency
Rated power
Input voltage
Input current
Permissible total differential pressure ²)
Sound pressure level ³)
Weight ca.
kW
Hz
3~ 50/60 Hz IP55 isulation material class F 1)
B 150 4RB220-0AH26-7 50 0.81 200D ... 240D 345Y...415Y 4.0D 2.3Y -370 490 58 24 B 151 4RB220-0AH26-7 60 0.94 220D ... 275D 380Y...480Y 4.0D 2.3Y -440 480 62 24
B 152 4RB220-0AH56-7 50 1.5 200D ... 240D 345Y...415Y 7.5D 4.3Y -370 650 58 28 B 153 4RB220-0AH56-7 60 1.75 220D ... 275D 380Y...480Y 7.6D 4.4Y -500 740 62 28
1~ 50/60 Hz IP55 with attached condenser for continuous operation
B 150s 4RB 220-0AV75-7 50 1.5 115 230 19.4 9.7 -370 600 58 30 B 151s 4RB 220-0AV75-7 60 1.75 115 230 20.6 10.3 -420 660 62 30
V
A
Vacuum mbar
Compressor mbar
dB(A)
kg
All G-4RB achieve the standards and norms of the low voltage directive (LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004, electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6.
1) For standard UL for ELECTRIC MOTOR UL 1004-1.
2) Relief-valve are available for limiting differential pressure.
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured at a distance of 1 m. The pump is throttled to an average suction pressure, a hose is connected to the discharge side (compressor) / suction side
(vacuum pump), but is not tted with relief valves.
Other voltage ranges
□ □
50Hz
3
~
185...225 V D/320...390 V Y 200...240 V D/345...415 V Y H 1
200...240 V D/345...415 V Y 200...275 V D/380...480 V Y H 6
345...415 V D 380...480 V D H 7
500 V D 575VD C 5
Machines according to the ATEX norm 94/4 EG are available for the whole performance range. Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
Further voltage range on request; please quote in plain text.
The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and temperature class F.
For the three phase machines the tolerances are +/- 10 % for xed voltage and
+/- 5 % for voltage range. The single phase machines are designed with a +/- 5 % tolerances. If only 90 % of the maxium allowed pressure will be used for the continuousoperating then the allowed voltage range add to +/- 10 %. For all single and three phase machines which designed according to the UL and CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp. + 6 %. The frequency tolerance is maximum +/- 2 %.
60Hz
↑↑
Changes in particular the quoted performance curve, datas and weights without prior notice. The gures are without obligations.
DYNAPUMPS
DYNAPUMPS Sydney-Melbourne-Brisbane-Perth Phone: 1300 788 579 E-mail:sales@dynapumps.com.au

G-4RB 4RB 310

Performance curve for Vacuum pump
Performance curve for Compressor
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
mbar
mbar
total pressure difference (vacuum)
p
total pressure difference (vacuum)
p
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
total pressure difference (gauge)
total pressure difference (gauge)
mbar
p
mbar
p
temperature rise T (in K)
on the air handled
total pressure difference (vacuum)
p
mbar
The performance curves are based on air at a temperature of 15 °C and an atmospheric pressure of 1013 mbar with a tolerance of +/- 10 %. The total pressure differences are valid for suction and ambient temperatures up to 25 °C. For other conditions please confer with us.
temperature rise T (in K)
on the air handled
mbar
total pressure difference (gauge)
Each G-4RB type can be applied both as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 55 as well as approbated for UL and CSA.
Technical data sheet Edition 04/2010 En
p
Selection and ordering data
Type 4RB310
Curve No.
Order No.
Fre­quency
Rated power
Input voltage
Input current
Permissible total differential pressure ²)
Sound pressure level ³)
Weight ca.
kW
Hz
3~ 50/60 Hz IP55 isulation material class F 1)
B 160 4RB310-0AH16-7 50 0.55 200D ... 240D 345Y...415Y 2.8D 1.6Y -250 250 57 16 B 161 4RB310-0AH16-7 60 0.63 220D ... 275D 380Y...480Y 3.0D 1.7Y -260 250 62 16
B 162 4RB310-0AH26-7 50 0.81 200D ... 240D 345Y...415Y 4.0D 2.3Y -280 350 57 17 B 163 4RB310-0AH26-7 60 0.94 220D ... 275D 380Y...480Y 4.0D 2.3Y -340 360 62 17
1~ 50/60 Hz IP55 with attached condenser for continuous operation
B 162s 4RB 310-0AV74-7 50 0.94 100 200 18.1 9.1 -250 350 57 18 B 163s 4RB 310-0AV74-7 60 1.1 100 200 24.8 12.4 -280 390 62 18
B 162s 4RB 310-0AV75-7 50 0.94 115 230 15.2 7.6 -250 350 57 18 B 163s 4RB 310-0AV75-7 60 1.1 115 230 18.0 9.0 -280 390 62 18
1~ 50 Hz IP55 with attached condenser for continuous operation
B 160s 4RB 310-0AV75-7 50 0.94 230 9.0 -250 250 57 18
V
A
Vacuum mbar
Compressor mbar
dB(A)
kg
All G-4RB achieve the standards and norms of the low voltage directive (LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004, electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6.
1) For standard UL for ELECTRIC MOTOR UL 1004-1.
2) Relief-valve are available for limiting differential pressure.
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured at a distance of 1 m. The pump is throttled to an average suction pressure, a hose is connected to the discharge side (compressor) / suction side
(vacuum pump), but is not tted with relief valves.
Other voltage ranges
□ □
50Hz
3
~
185...225 V D/320...390 V Y 200...240 V D/345...415 V Y H 1
200...240 V D/345...415 V Y 200...275 V D/380...480 V Y H 6
345...415 V D 380...480 V D H 7
500 V D 575VD C 5
Machines according to the ATEX norm 94/4 EG are available for the whole performance range. Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
1
~
100 / 200 V 100 / 200 V V 4
115 / 230 V 115 / 230 V V 5
230V --- A 1
Further voltage range on request; please quote in plain text.
The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and temperature class F.
For the three phase machines the tolerances are +/- 10 % for xed voltage and
+/- 5 % for voltage range. The single phase machines are designed with a +/- 5 % tolerances. If only 90 % of the maxium allowed pressure will be used for the continuousoperating then the allowed voltage range add to +/- 10 %. For all single and three phase machines which designed according to the UL and CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp. + 6 %. The frequency tolerance is maximum +/- 2 %.
60Hz
↑↑
Changes in particular the quoted performance curve, datas and weights without prior notice. The gures are without obligations.
DYNAPUMPS
DYNAPUMPS Sydney-Melbourne-Brisbane-Perth Phone: 1300 788 579 E-mail:sales@dynapumps.com.au

G-4RB 4RB 320

Performance curve for Vacuum pump
Performance curve for Compressor
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
mbar
mbar
total pressure difference (vacuum)
p
total pressure difference (vacuum)
p
suction capacity V (m³/h)
power requirement P
on the pump shaft (kW)
total pressure difference (gauge)
total pressure difference (gauge)
mbar
p
mbar
p
temperature rise T (in K)
on the air handled
total pressure difference (vacuum)
p
mbar
The performance curves are based on air at a temperature of 15 °C and an atmospheric pressure of 1013 mbar with a tolerance of +/- 10 %. The total pressure differences are valid for suction and ambient temperatures up to 25 °C. For other conditions please confer with us.
temperature rise T (in K)
on the air handled
mbar
total pressure difference (gauge)
Each G-4RB type can be applied both as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 55 as well as approbated for UL and CSA.
Technical data sheet Edition 04/2010 En
p
Selection and ordering data
Type 4RB320
Curve No.
Order No.
Fre­quency
Rated power
Input voltage
Input current
Permissible total differential pressure ²)
Sound pressure level ³)
Weight ca.
kW
Hz
3~ 50/60 Hz IP55 isulation material class F 1)
B 170 4RB320-0AH46-7 50 1.1 200D ... 240D 345Y...415Y 5.4D 3.1Y -440 480 59 29 B 171 4RB320-0AH46-7 60 1.3 220D ... 275D 380Y...480Y 5.4D 3.1Y -480 460 63 29
B 172 4RB320-0AH56-7 50 1.5 200D ... 240D 345Y...415Y 7.5D 4.3Y -440 540 59 30 B 173 4RB320-0AH56-7 60 1.75 220D ... 275D 380Y...480Y 7.5D 4.3Y -560 600 63 30
1~ 50/60 Hz IP55 with attached condenser for continuous operation
B 170s 4RB 320-0AV74-7 50 1.5 100 200 22.3 11.2 -400 550 59 32 B 171s 4RB 320-0AV74-7 60 1.75 100 200 23.7 11.85 -390 540 63 32
B 170s 4RB 320-0AV75-7 50 1.5 115 230 19.4 9.7 -400 550 59 32 B 171s 4RB 320-0AV75-7 60 1.75 115 230 20.6 10.3 -390 540 63 32
V
A
Vacuum mbar
Compressor mbar
dB(A)
kg
All G-4RB achieve the standards and norms of the low voltage directive (LVD)2006/95/EC, rotating electrotechnical motor EN 60034-1-2004, electromagnetic compatibility(EMC)EN55014-1/2,EN61000-2/-3/-4/-6.
1) For standard UL for ELECTRIC MOTOR UL 1004-1.
2) Relief-valve are available for limiting differential pressure.
3) Measuring-surface sound-pressure level acc. to DIN EN 21680, measured at a distance of 1 m. The pump is throttled to an average suction pressure, a hose is connected to the discharge side (compressor) / suction side
(vacuum pump), but is not tted with relief valves.
Other voltage ranges
□ □
50Hz
3
~
185...225 V D/320...390 V Y 200...240 V D/345...415 V Y H 1
200...240 V D/345...415 V Y 200...275 V D/380...480 V Y H 6
345...415 V D 380...480 V D H 7
500 V D 575VD C 5
Machines according to the ATEX norm 94/4 EG are available for the whole performance range. Following types available: Category 3 G, 3/2 G, 3 D and 3/2 D.
Further voltage range on request; please quote in plain text.
The motors are designed according to the DIN EN 60 034 / DIN IEC 34-1 and temperature class F.
For the three phase machines the tolerances are +/- 10 % for xed voltage and
+/- 5 % for voltage range. The single phase machines are designed with a +/- 5 % tolerances. If only 90 % of the maxium allowed pressure will be used for the continuousoperating then the allowed voltage range add to +/- 10 %. For all single and three phase machines which designed according to the UL and CSA norm (UL 1004-1) the maximum allowed voltage tolerances are - 10 % resp. + 6 %. The frequency tolerance is maximum +/- 2 %.
60Hz
↑↑
Changes in particular the quoted performance curve, datas and weights without prior notice. The gures are without obligations.
DYNAPUMPS
DYNAPUMPS Sydney-Melbourne-Brisbane-Perth Phone: 1300 788 579 E-mail:sales@dynapumps.com.au