Dynasonics iSonic-4000 Specifications

iSonic 4000
Open-Channel Flow Meter
DESCRIPTION
An economical open-channel flow meter, iSonic 4000 measures level, flow rate and total volume of water flowing through weirs and flumes. The meter includes a non-contact ultrasonic level sensor to detect the water level and then calculates the flow rate and total volume using the Gauckler-Manning or other equations based on characteristics of the channel. All the measurements are available over Modbus RTU and can be logged for historical records.
BENEFITS
• Measure level, flow rate and total volume with a single device
• Simple setup for flumes and weirs
• Retain a historical log of all measurements
• Easily connect up to SCADA systems with Modbus RTU
• Rugged IP67 powder coated aluminum enclosure
OPERATION
Based on empirical formulas, the iSonic 4000 calculates the flow rate based on the geometry of the channel or primary element and water depth. The level sensor measures the depth of the water used in the calculation.
The iSonic 4000 includes a selection of primary elements with preprogrammed tables to simplify the setup, including:
• Parshall flumes
• Manhole flumes
• V-notch weirs
Additionally, you can enter custom tables using the Flow Meter Tool software.
PUMP CONTROL OPTION
The Pump Control option automatically starts and stops the pump based on water level.
Tank Volume
or
Max.
Min.
Open Channel Flow Rate
Time
PART NUMBER
• DK-1S-S
◊ iSonic 4000 transmitter
◊ Level sensor with 32 ft (10 m) cable
◊ USB cable
◊ Flow Meter Tool configuration software
• Optional bracket for level sensor
APPLICATIONS
Open channels with a primary element are a cost effective solution for managing varying flow rates in unpressurized systems. The iSonic 4000 flow meter performs best when used with a primary element, such as a flume or weir, and where the sediment does not build up.
• Flow into water treatment plants from reservoirs
• Storm and sanitary sewer systems
• Effluent from water resource recovery or wastewater treatment
• Industrial discharge
• Agriculture irrigation channels
Pump Control
HYB-DS-02510-EN-02 (October 2017)
Closed (NO) / Open (NC)
Open (NC) / Closed (NO)
Product Data Sheet
iSonic 4000, Open-Channel Flow Meter
SPECIFICATIONS
Type iSonic 4000 Auxiliary power 92…275V AC (50/60 Hz), < 14 VA optional 9…36V DC, < 4 W Analog output 4…20 mA, 0…20 mA, 0…10 mA ≤ 800 Ohm, active or passive; Assigned parameter depends on flow meter mode Level sensor input 4…20 mA from level sensor
2 open collectors; passive: max. 32V DC, 0…100 Hz 100 mA, 100…10.000 Hz 20 mA; active: 24V DC, max. 20 mA;
Digital outputs
Digital input 5…30V DC; totalizer reset, positive return zero, BEACON/AquaCUE connectivity Programming port Mini USB, IP67 Configuration 3 front-panel mounted push-buttons Communication RS485 Modbus RTU, Modbus TCP/IP Ethernet, BEACON/AquaCUE connectivity Pulse length Configurable up to 2000 msec Datalogger 2 MB capacity with 130,000 logged lines: date, level, flow rate, tank volume Display Graphical LCD 64 × 128, backlight, actual flow rate, totalizers, status display Body Die cast powder-coated aluminium, protection class IP67 Cable inlet Supply and signal cables 2 × M20; cable glands included Signal cable From meter M20; cable gland included Ambient temperature -20…60° C
Sensors
Security Three level password Languages English, Spanish, French, German, Italian, Czech, Russian
Channel selection
Select active pulse, min/max. alarm, error messages or pump control Solid-state relay (n.o./n.c.) max. 230V AC, 500 mA, 1 Hz; Function is linked with open collector output 2
Measuring range Offset Beam width Material Accuracy Deadband
0…49.21 in.
(0…1250 mm)
2 in.
(50 mm)
2 in.
(50 mm)
PVDF
0.125 in. (3 mm)
2 in.
(50 mm)
Contracted rectangular weir, suppressed rectangular weir, Cipoletti weir; V-notch weir (30°, 45°, 60°, 90°); Parshall flume (1, 2, 3, 6, 9, 12, 18, 24, 36, 48 and 60 in.); Manhole flume (4, 6, 8, 10 and 12 in.); table entry, exponential equation, Manning rectangle flume, Manning pipe
DIMENSIONS
9.80 in.
(249 mm)
5.83 in.
(148 mm)
3.15 in.
(60 mm)
6.46 in.
(164 mm)
2.56 in.
(65 mm)
Ø 0.20 in. (5.2 mm)
M20 (×2)
3.15 in.
(60 mm)
Control. Manage. Optimize.
Dynasonics is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2017 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Oce (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11
Loading...