You have just purchased DYNASET hydraulic equipment!
The equipment allows you to maximize the productivity and
efficiency of your mobile machine. Read this User Manual
before using your new equipment. It contains important
information that will help you to take the full advance of the
technical features avaible in your equipment.
Please contact us for any feedback you might have on our
products. Your feedback is important to us for improving our
products and customer service.
We are constantly developing and releasing new innovations.
Please visit on our website and social media channels for the
latest news and updates.
Picture 1: Type plate 9
Picture 2: Main components of HPW-DUST system 10
Picture 3: Operating principles 15
Picture 4: Basic HPW-DUST installation diagram 16
Picture 5: Dual Water Circuit installation diagram 17
Picture 6: Single Water Circuit installation diagram 18
Picture 7: Example installation to open centre hydraulic system 19
Picture 8: Example installation to closed centre hydraulic system without PC-SAE 20
Picture 9: Positioning the HPW-pump 21
Picture 10: Positioning the dust suppression nozzles 22
Picture 11: Positioning the water solenoid valve 23
Picture 12: Installation to a water line 24
Picture 13: HPW-pump’s on-o switch 25
Picture 14: High power water solenoid valve push-button 25
Picture 15: High power water mode in single water circuit 26
Picture 16: Before operating the HPW-DUST system 29
Picture 17: Location of leakage detectors in HPW 31
Picture 18: Clean water lter 33
This manual contains general information about assembly, installation, operation
and maintenance of DYNASET HPW DUST High Pressure Dust Suppression System.
ATTENTION!
Read this user manual before installation, use or maintenance of the HPW
DUST system to ensure proper handling, operation and maintenance right
from the beginning. Pay attention to warnings and safety instructions.
READ CHAPTER ”2. SAFETY” for more information.
HIGH PRESSURE DUST SUPPRESSION
GENERAL
1.1. PRODUCT INFORMATION
DYNASET HPW-DUST Dust Suppression System converts the hydraulic power of
a mobile machine into a high pressure water mist. It is integrated onto the base
machine’s attachment head or where the dust suppression is needed to get the
maximum effect. The system creates an effective high pressure dust control with
optimal water consumption. High pressure water uses less water and gives better
dust suppression performances with a smaller water drop size than traditional low
pressure dust suppression systems.
HPW-DUST has different nozzle and pump configurations to fit all vehicles and
dust suppression applications. The system can also be equipped with a Double
Dust boosting system that multiplies the dust suppression power. The HPW-DUST
also comes with a power washing pistol for all power washing applications.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
7
7
HIGH PRESSURE DUST SUPPRESSION
1.2. PRODUCT IDENTIFICATION
1. Product group HPW-DUST High Pressure Dust Suppression System.
2. WATER PUMP (Listed below)
HPW 200
GENERAL
Maximum pressure: 200 bar
Maximum flow: 30 l/min
HPW 220
Maximum pressure: 220 bar
Maximum flow: 50 l/min
HPW 180
Maximum pressure: 180 bar
Maximum flow: 90 l/min
HPW 130
Maximum pressure: 130 bar
Maximum flow: 180 l/min
3. DOUBLE DUST (optional)
Provides dual stage power output. Lower stage is typically set to one third from
higher power stage. Lower stage reduces water consumption and higher stage
gives extra boost for dust suppression when needed.
Hydraulic pressure max: 210 bar
Hydraulic flow max: 40 l/min
Hydraulic pressure max: 210 bar
Hydraulic flow required: 70 l/min
Hydraulic pressure max: 210 bar
Hydraulic flow max: 115 l/min
Hydraulic pressure max: 250 bar
Hydraulic flow max: 140 l/min
8
8
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
1.3. TYPE PLATE
Type plate is located on the HPW pump.
Made in Finland
1
2
4
7
8
POWERED BY HYDRAULICS
Type
Code
Oil Flow
Qw = 30 l/min
Pw = 200 bar
Manufacturer:
Dynaset Oy
33470 Ylöjärvi Finland
HPW 200/30 - 45 ST
45 l/min
HIGH PRESSURE DUST SUPPRESSION
3
5
12345-6789Dxxxxxxxxx
Nr
210 bar
www.dynaset.com
info@dynaset.com
Tel +358 3 3488200
11/15
YearPressure
6
GENERAL
Picture 1: Type plate
The products type plate shows the following information.
1. Product identification key
2. Product code
3. Serial number
4. Maximum hydraulic flow
5. Maximum hydraulic pressure
1.4. HPW-DUST SYSTEM LINE-UP
• HPW DUST 200
• HPW DUST 200 DOUBLE DUST
• HPW DUST 220 DOUBLE DUST
• HPW DUST 180 DOUBLE DUST
6. Production month / year
7. Output water flow
rate and pressure.
8. Manufacturer’s contact
information
• HPW DUST 130 DOUBLE DUST
For specific characteristics of the HPW-DUST System line up READ CHAPTER “10.
TECHNICAL SPECIFICATIONS”
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
9
9
HIGH PRESSURE DUST SUPPRESSION
1.5. MAIN COMPONENTS OF HPW-DUST SYSTEM
GENERAL
Picture 2: Main components of HPW-DUST system
1. HPW-Pump
2. Control valves
3. Water intake filter
4. High pressure water nozzles
5. Spray gun with 10m hose
10
10
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
2. SAFETY
2.1. SAFETY PRECAUTIONS
ATTENTION!
Operators and maintenance personnel must always comply with local
safety regulations and precautions in order to close out the possibility of
damages and accidents.
The pressure in both hydraulic oil and water circuits of HPW-DUST system is
considerably high. Keep the condition of your equipment and hydraulic system
under constant observation.
HIGH PRESSURE DUST SUPPRESSION
SAFETY
WARNING
HIGH PRESSURE WATER AND OIL!
Can cause severe injuries.
Always wear appropriate clothing
and safety equipment.
Couplings, valves and hoses need to be kept tight and clean to avoid possible
leakages. Leaks in the hydraulic system must be repaired immediately to avoid
injuries caused by high pressure blowouts.
In order to avoid accidents, it is not allowed to clean or inspect HPW-DUST system
when hydraulic fluid circuit is pressurized. Prior to any cleaning, inspection and
service, hydraulic system of your base machine must be stopped and all hydraulic
fluid circuits must be depressurized.
Prevent nozzles, water circuit and pipeline from freezing. Draining and air flushing
of the water circuit have to performed before ambient temperature reaches 0°C
or lower.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
11
2.2. OPERATING SAFETY
When operating the HPW-DUST system, beware of the unit parts warmed by hot
hydraulic oil.
RISK OF BURNS!
The unit parts and hydraulic oil can
be hotter than 80 °C!
Wear personal safety equipment!
HIGH PRESSURE DUST SUPPRESSION
SAFETY
WARNING
Never aim high pressure water at a person.
WARNING
HIGH PRESSURE WATER!
Never aim high pressure water at a person.
This can cause severe injuries.
ATTENTION!
Do not exceed the maximum pressure, temperature or load.
2.3. MAINTENANCE SAFETY
ATTENTION
Installation and service of hydraulic equipment must be performed by
qualified and experienced personnel only.
12
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
NOTE!
READ OPERA
SPLATTERS.
When carrying out any maintenance to HPW-DUST system keep the
components of the system clean. This is to ensure safe, reliable and longlife
operation of your equipment.
Hydraulic system of the base machine should be maintained according to the
service program.
2.4. WARNING LABELS
Product recipient is obligated to place warning labels on the DYNASET product.
Attach labels to visible and appropriate place onto or close to DYNASET product
where it’s easily seen. Clean surface with solvent detergent before attaching labels.
HIGH PRESSURE DUST SUPPRESSION
SAFETY
TING
INSTRUCTIONS.
BEWARE OF HOT
SURFACE.
USE EAR PROTECTION
AND SAFETY
GOGGLES.
KEEP FROM
FREEZING.
BEWARE OF HIGH
PRESSURE
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
13
HIGH PRESSURE DUST SUPPRESSION
SAFETY
14
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
3. OPERATING PRINCIPLES
3.1. OPERATING DESCRIPTION
1. The HPW-DUST Dust Suppression System uses the power from the base
machine’s hydraulic system.
2. The HPW-DUST patented piston-to-piston pump converts the hydraulic power
into high pressure water.
3. High pressure water is pumped to the carefully designed dust suppression
nozzles which create the high pressure water mist. High pressure water mist
increases the mass of the dust particles and forces the dust to fall onto the
ground.
HIGH PRESSURE DUST SUPPRESSION
OPERATING PRINCIPLES
Picture 3: Operating principles
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
15
3.2. HPW-DUST
DYNASET HPW-DUST System provides continuous dust suppression with 2 pairs
of nozzles. Dust suppression is controlled with hydraulic solenoid valve of the
HPW-Pump.
HIGH PRESSURE DUST SUPPRESSION
OPERATING PRINCIPLES
Picture 4: Basic HPW-DUST installation diagram
1. Basic nozzles
16
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
3.3. HPW-DUST DOUBLE DUST
DYNASET HPW-DUST Double Dust boosting System multiplies the dust suppression
power. Double Dust is implemented in two different ways:
3.3.1. DUAL WATER CIRCUIT (DWC)
Dual Water Circuit comes with basic and high power nozzle pairs. Basic pair of
nozzles provide continuous dust suppression. High power pair is controlled by
water solenoid valve and can be used when suppression boost is needed.
HIGH PRESSURE DUST SUPPRESSION
OPERATING PRINCIPLES
Picture 5: Dual Water Circuit installation diagram
1. Basic nozzles
2. High power nozzles
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
3. High power water
solenoid valve
17
3.3.2. SINGLE WATER CIRCUIT (SWC)
Single Water Circuit comes with one type of nozzles. The output water flow and
pressure is controlled with hydraulic valve kit. Hydraulic valve provides two
separate hydraulic flows to the HPW-pump. Lower hydraulic flow to the continuous
dust suppression and higher hydraulic flow to the high power dust suppression.
HIGH PRESSURE DUST SUPPRESSION
OPERATING PRINCIPLES
18
Picture 6: Single Water Circuit installation diagram
1.Basic nozzles2.Hydraulic valve
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
4.INSTALLATION OF THE HPW-DUST SYSTEM
4.1. INSTALLATION TO A HYDRAULIC LINE
INSTALLATION
The HPW-DUST
It is recommended to use DYNASET HPW-VR-PA -pump in the installation.
In the picture 7 is an example of installing the HPW-DUST system into a
open centre hydraulic line.
system is installed into the base machine’s existing hydraulic line.
Picture 7: Example installation to open centre hydraulic system
1.DYNASET HPW-VR-PA -pump
2.Base machines variable
displacement pump
3.Open centre directional
control valves
4.Oil cooler
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
5.Oil filter
6.Oil tank
7.Solenoid valve
8.DYNASET PC-SAE pressure
compensator
19
HIGH PRESSURE DUST SUPPRESSION
INSTALLATION
In the picture 8 is an example of installing the HPW-DUST system into a closed
centre hydraulic line without PC-SAE.
Picture 8: Example installation to closed centre hydraulic system without
PC-SAE
1.DYNASET HPW pump
2.Base machines variable
displacement pump
3.Closed centre directional
control valves
4.Oil cooler
Ensure that the hydraulic flow of the base machine is sufficient to run the HPWDUST system. At least the nominal hydraulic flow must be available to get the
maximum dust suppression power.
5.Oil filter
6.Oil tank
7.Solenoid valve
8.DYNASET Shuttle valve
20
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
ATTENTION!
Ensure that the filtering degree and cooling capacity of the hydraulic
system are sufficient. READ CHAPTER ”10. TECHNICAL SPECIFICATIONS” for
more information.
4.2. HYDRAULIC FLUIDS
To use proper hydraulic fluid READ CHAPTER ”6.2. Hydraulic fluids” for more
information.
HIGH PRESSURE DUST SUPPRESSION
INSTALLATION
4.3. POSITIONING THE HPW-DUST COMPONENTS
4.3.1. POSITIONING THE HPW-PUMP
HPW-pump is recommended to install onto bace machines upper structure. It
is recommended to use rubber cushions in HPW-pump installation to reduce
vibration and noise.
Picture 9: Positioning the HPW-pump
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
21
HIGH PRESSURE DUST SUPPRESSION
4.3.2. POSITIONING THE DUST SUPPRESSION NOZZLES
INSTALLATION
22
Picture 10: Positioning the dust suppression nozzles
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
1. Basic dust suppression nozzles should be installed onto attachment tool. Nozzle
position must ensure water jet staight into to the prosessing area for example
between the crusher jaws.
2. High pressure dust suppression nozzles should be installed onto attachment
tool as well. Nozzle position should be chosen to cover as wide area as possible.
4.3.3. POSITIONING THE WATER SOLENOID VALVE
High power dust suppression is controlled by water solenoid valve, which is
recommended to install to a basic boom’s end in suitable place to be kept clean
an covered against impacts.
INSTALLATION
Picture 11: Positioning the water solenoid valve
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
23
HIGH PRESSURE DUST SUPPRESSION
4.4. INSTALLATION TO A WATER LINE
INSTALLATION
24
Picture 12: Installation to a water line
1. Connect water intake line into water intake connection of HPW-pump.
2. Water can be taken from a tank or a tap.
3. Water filter is required in water intake line.
4. Ensure correct suction hose diameter.
5. Maximum water suction head is 3 meters. Maximum head depends on the
lenght and diameter of the suction line. Correct feed pressure is 3 to 16 bar.
6. Ensure water temperature is between +5 to +50
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
o
C.
HIGH PRESSURE DUST SUPPRESSION
4.5. CONTROL WIRING
4.5.1. HPW-PUMP/DUST SUPPRESSION ON-OFF SWITCH
HPW-pump is switched on by activating the hydraulic solenoid valve. The HPWpump’s on-off switch is recommended to install in the base machine’s cabins aux
panel.
INSTALLATION
Picture 13: HPW-pump’s on-off switch
4.5.2. HIGH POWER WATER SOLENOID VALVE PUSH-BUTTON
In the dual water circuit high pressure dust suppression mode is switched on by
activating the water solenoid valve. The water solenoid valve is controlled by pushbutton and impulse relay. The dust suppression push-button is recommended to
install into a boom’s control stick.
Picture 14: High power water solenoid valve push-button
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
25
HIGH PRESSURE DUST SUPPRESSION
4.5.3. HIGH POWER WATER MODE IN SIGLE WATER CIRCUIT
Basic and high power dust suppression modes in sigle water circuit is controlled
by 3-pole switch. Switch controls the hydaulic solenoid valves of HPW-pump.
INSTALLATION
Picture 15: High power water mode in single water circuit
26
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
INSTALLATION
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
27
HIGH PRESSURE DUST SUPPRESSION
INSTALLATION
28
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
5. OPERATION
After having ensured the proper mechanical and hydraulic installation of the
HPW-DUST system it is ready for use.
5.1. BEFORE OPERATING THE HPW-DUST SYSTEM
OPERATION
Picture 16: Before operating the HPW-DUST system
1. Ensure that the water filter is clean and in place.
2. Fill the water tank with clean water or ensure water line connection from a tap.
NOTE!
Maximum feed pressure to the HPW-pump is 16 bar
5.2. STARTING AND STOPPING THE HPW-DUST SYSTEM
HPW-DUST system is started and stopped by activating/deactivating hydraulic
flow to the HPW-pump. On/off switch is typically installed into cabin’s aux panel.
5.3. HIGH POWER DUST SUPPRESSION
In double dust system made with dual water circuit, the high power dust suppression mode is activated with push-button installed into boom joystic. Pressing the
button once activates the and pressing the button again disables the high power
mode.
In double dust system made with single water circuit, the basic and high power
dust suppression is controlled by 3-pole switch which is typically installed into
cabin’s aux panel.
The high power dust suppression is intended for discontinuous use, but if the
water pipeline is available, the high power mode can be used on continuous basis
when necessary.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
29
HIGH PRESSURE DUST SUPPRESSION
5.4. WORKING IN COLD TEMPERATURES
To prevent pipes and HPW-DUST system from freezing in cold season, the pump,
water lines and water tank should be dewatered after a working shift. Open the
drain plug of the water tank and drain out the water. After tank is empty run the
HPW-pump dry for a while until all water is removed from water circuit.
ATTENTION!
Prevent the HPW-DUST system from freezing.
OPERATION
30
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
6. MAINTENANCE
6.1. MAINTENANCE INTERVAL
All maintenance must be complied with as they are scheduled in this manual.
The following table provides maintenance schedule for DYNASET HPW-DUST
systems.
HIGH PRESSURE DUST SUPPRESSION
MAINTENANCE
CHECK POINTS
Observe HPW pumps leakage detactorsx
Clean HPW-DUST systemx
Clean water intake lterx
Change water intake lterx
Daily / after
daily use
WeeklyEvery 1500 hours
or if necessary
Check constantly whether the fluid dropping from pump’s leakage detectors is
growing. Replace sealing in proper time to exclude intermixing of hydraulic oil and
pumping fluid. Sealings replace instructions can be found in HPW User Manual.
Picture 17: Location of leakage detectors in HPW
NOTE!
Maintenance of the HPW-pump according to HPW User Manual!
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
31
6.2. HYDRAULIC FLUIDS
Wide range of standard hydraulic fluids can be used with DYNASET hydraulic
equipment. Depending on the operating temperature, following mineral hydraulic
oils are recommended:
Mineral hydraulic oilOperation temperature up to
ISO VG 32S60 °C
ISO VG 46S70 °C
ISO VG 68S80 °C
Synthetic and bio-oils can also be used if their viscosity characteristics and
lubricating efficiency are similar to the mineral oils.
Automatic transmission fluids and even engine oils can be used, provided that
they are allowed to be used in hydraulic system of your base machine.
HIGH PRESSURE DUST SUPPRESSION
MAINTENANCE
For the hydraulic fluid change interval follow the base machine’s maintenance
instructions.
To use special hydraulic fluids with DYNASET equipment, please contact the
nearest DYNASET representative for more information.
6.3. CLEAN THE HPW-DUST SYSTEM
ATTENTION!
Keep the HPW-DUST system clean to enable its safe and longlife operation.
Check and clean your HPW-DUST system after every work shift.
32
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
6.4. CLEAN WATER FILTER
Check and clean water filter weekly.
HIGH PRESSURE DUST SUPPRESSION
MAINTENANCE
Picture 18: Clean water filter
Remove the water filter. Wash the water filter under clean water to remove all soil
and dirt from the filter. Renew the filter if necessary.
6.5. TROUBLESHOOTING
Performing the maintenance tasks requires a qualified hydraulic mechanic.
Please, contact DYNASET authorized workshop or dealer for more maintenance
information.
FAILUREREASONCORRECTIVE ACTION
HPW-DUST system does not
work.
Hydraulic ow not
sucient or no hydraulic
ow at all.
Hydraulic pressure too low. Adjust the hydraulic pressure.
Hydraulic ow reversed.
Enable or adjust the hydraulic
ow.
Check and reconnect hydraulic
hoses. Pressure hose should be
connected to P-port and return
hose to T-port.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
33
HIGH PRESSURE DUST SUPPRESSION
MAINTENANCE
FAILUREREASONCORRECTIVE ACTION
No water in tanks.Check and ll the water tank.
HPW-DUST system does not
deliver water
Intake hose detached or
hose breathes.
Water supply line clogged.
Nozzle is cloggedCheck and clean nozzle lter.
Check and x the hose and
connectors.
Check water lter and clean
thoroughly.
Troubleshooting for HPW pump can be found in HPW User Manual.
34
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
7. MANUFACTURER’S LIMITED WARRANTY
1. Warranty coverage
All hydraulic accessories manufactured by DYNASET OY are subject to the terms
and conditions of this limited warranty. Products are warranted to the original
purchaser to be free from defects in materials or workmanship. Exclusions from
warranty are explained in item Exclusions from warranty.
2. Beginning of warranty period
Warranty period begins from the delivery date of the product. Delivery is
considered to be done on the date when installation has been accomplished or
purchaser has taken the product in use. Product is considered as taken in use at the
date when DYNASET OY has delivered the product to purchaser, unless separately
agreed otherwise by written agreement.
3. Warranty period
Warranty period is twenty four (24) months based on maximum of 2000 hours
usage during this time period. In cases where the system is provided complete with
certain special components (e.g. drive unit), those components are considered as
a subject to their manufacturer’s warranty.
WARRANTY
4. Warranty procedures
Immediately upon identifying a problem which purchaser believes to be a failure
subject to the product’s limited warranty, purchaser must contact primary to the
seller of the product. Contact must be made as soon as possible, latest thirty (30)
days after the problem was identified. Seller and/or manufacturer technical staff
determines the nature of the problem primarily by phone or e-mail. Purchaser
commits to give necessary information and to perform routine diagnostic
procedures in order to determine the nature of the problem and necessary
procedures.
5. Warranty repairs
If the product is found to be defective during the warranty period, DYNASET
OY will, at its option, either repair the product, author it to be repaired at its
authorized workshop or exchange the defective product. If the product must be
repaired elsewhere than premises of DYNASET OY or authorized workshop, all
costs excluded from this warranty (traveling and waiting hours, daily allowance,
traveling expenses and uninstallation/reinstallation costs) will be charged from
the purchaser. If the problem is not covered by this limited warranty, DYNASET OY
has the right to charge purchaser of troubleshooting and repairing.
6. Delivery terms of warranty repair
If the product is found possible to be defective under this limited warranty and it
needs to be repaired, DYNASET OY gives Warranty Return Number (WRN). Items
being returned must be shipped, at the purchaser’s cost, adequately packed for
shipment, to the DYNASET OY or to other location authored by DYNASET OY.
Shipment documents must contain:
• Purchaser’s name and contact information
• Receipt of original purchase
• WRN code
• Problem description
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
35
HIGH PRESSURE DUST SUPPRESSION
WARRANTY
7. Warranty of repaired product
Warranty period of the product repaired under this limited warranty continues to
the end of original warranty period.
8. Exclusions from warranty
This warranty shall not apply to:
• Failures due to normal wear and tear, improper installation, misuse, abuse,
negligence, purchaser selection of improper product to intended use, accident,
improper filtration of hydraulic oil or intake water or lack of maintenance.
• Cost of maintenance, adjustments, installation or startup.
• Coating, hydraulic oil, quick couplings and interconnection hoses (internal or
external to system assemblies).
• Products altered or modified in a manner not authorized by DYNASET OY in
writing.
• Products which have been repaired during warranty period by others than
DYNASET OY or its authorized workshop.
• Costs of any other damage or loss, whether direct, indirect, incidental, special
or consequential, arising out of the use of, or the inability to use, the product.
• Telephone or other communications expense.
• Product that is used in exceptional conditions, considered to cause excessive
wear and tear.
• Faults caused by nature phenomenon’s like flood, thunder, etc.
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
8. PRODUCT DISPOSAL
Dispose and recycle all DYNASET products and their packaging environmentally
responsible way.
Do not dispose used oils, electrical components, batteries or any other hazardous
waste with normal waste. They are harmful for the environment and can be
recycled for re-use.
Contact your local waste recycling facility for more information about recycling
hazardous waste.
NOTE!
Always act according to the waste legislation, regulations and
recommendations in waste disposal and waste recycling issued by your
local authorities.
HIGH PRESSURE DUST SUPPRESSION
PRODUCT DISPOSAL
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
37
HIGH PRESSURE DUST SUPPRESSION
PRODUCT DISPOSAL
38
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
DECLARATION OF CONFORMITY
9. DECLARATION OF CONFORMITY
We hereby declare that the design and manufacture of the product stated below
are in conformity with the provisions of the European Parliament and Councils on
the harmonization of the laws of Member States on the safety of machines.
Machine directive 2006/42/EC
LVD directive 2014/35/EU
EMC directive 2014/30/EU
RoHS directive 2011/65/EU
Applied conformity standards:
CEN EN ISO 4413: EN ISO 4413:2010 Hydraulic fluid power -
General rules and safety requirements for systems and their
components.
EN60204-1 Safety of machinery – Electrical equipment of
machines.
Manufacturer: DYNASET OyMenotie 3, FI-33470 Ylöjärvi, Finland
Product group: HIGH PRESSURE WATER PUMPS
Product: HPW-DUST High pressure dust suppression system
If the device has been modified by someone other than the manufacturer or
without the manufacturer’s permission, this declaration is not valid.
Timo Nieminen
R&D Manager
Ylöjärvi, Finland 20.04.2016
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
39
HIGH PRESSURE DUST SUPPRESSION
DECLARATION OF CONFORMITY
40
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HIGH PRESSURE DUST SUPPRESSION
10. TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
HPW-DUST
200
HPW-DUST
200
DOUBLE
DUST
HPW-DUST
220
DOUBLE
DUST
HPW-DUST
DOUBLE
WATER POWER
Basic ow
@ recommended
l/min
(gpm)
21
(5.5)
10
(2.6)
21
(5.5)
pressure
High Power ow
@ recommended
l/min
(gpm)
-30
(7.9)
50
(13.2)
pressure
Pressure
recommended
Pressure maxbar
Nozzle (basic)pcs
High power nozzlepcs
bar
(psi)
(psi)
140
(2000)
200
(2900)
42446
-2222
140
(2000)
200
(2900)
140
(2000)
220
(3200)
WATER INTAKE REQUIREMENTS
Recommended
in3/4”3/4”1”1 1/4”2”
suction hose size
Suction lter ow
min
Recommended
l/min
(gpm)
50
(13.2)
50
(13.2)
80
(21.1)
80 or better
lter mesh
Suction head maxm (ft)3 (9.8)
Feed pressurebar (psi)-0,3...16 (-43.5...232)
HYDRAULIC POWER REQUIREMENTS
Oil ow max.l/min
(gpm)
Pressure max.bar
(psi)
HYDRAULIC CONNECTIONS
Pressure line
P1/2"1/2"3/4”3/4”3/4”
40
(10.6)
210
(3000)
40
(10.6)
210
(3000)
70
(18.5)
210
(3000)
(female)
Return line
T1/2"1/2"3/4”3/4”3/4”
(male)
HYDRAULIC FLUID REQUIREMENTS
ViscocitycSt10-200 / optimum 25-35
Temperature° C (° F)max. 70
Filter ratio,
μm25 or better
(160 )
recommendation
180
DUST
45
(11.9)
90
(23.8)
140
(2000)
180
(2600)
130
(34.3)
115
(30.4)
210
(3000)
HPW-DUST
130
DOUBLE
DUST
60
(15.9)
180
(47.6)
130
(1900)
130
(1900)
200
(52.8)
140
(37.0)
250
(3600)
Cooling capacity
kW22366
requirement
Gallons are U.S. liquid gallons
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
41
HIGH PRESSURE DUST SUPPRESSION
TECHNICAL SPECIFICATIONS
42
Dynaset Oy | Menotie 3, FI-33470 Ylöjärvi, Finland | tel: +358 3 3488 200 | info@dynaset.com | www.dynaset.com
HG Hydraulic Generator
HGV POWER BOX Variable Hydraulic Generator System
HGV Variable Hydraulic Generator System
HWG Hydraulic Welding Generator
HGG Hydraulic Ground Power Generator
HIGH PRESSURE WATER
HPW Hydraulic High Pressure Water Pump
HPW Hydraulic Power Washer
KPL High Pressure Street Washing Unit
HPW-DUST High Pressure Dust Suppression System
PPL High Pressure Pipe Cleaning Unit
HPW-FIRE High Pressure Fireghting System
FP Fire Fighting Piercing Kit
HDF Hydraulic Drilling Fluid Pump
JPL High Pressure Bin Washing System
HSP Hydraulic Submersible Pump
MAGNET POWER
HMG PRO Hydraulic Magnet Generator
MAG Lift Magnet
HMAG PRO Hydraulic Magnet
Hydraulic Power Take-o (PTO)
Hydraulic Power Unit Technology
HEU Hydraulic Expansion Unit
HRU Hydraulic Rescue Unis
De-Icing Technology
Installation Valves
HHK Hydraulic Grinder
HV/HVY Hydraulic Winch / Winch Unit
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.