Dynapar SERIES X25 Data Sheet

HEAVY DUTY
SERIES X25
For Hazardous Location Application
Key Features
Approved for NEC Class 1&2, Div 1&2, Groups C,D,E,F,G
Rugged Enclosure with 1/2 Conduit Entry
High 5000 PPR Capability
Dynapar
brand
SPECIFICATIONS
STANDARD OPERATING CHARACTERISTICS
Code: Incremental Resolution: 1 to 5000 PPR (pulses/revolution) Accuracy: (Worst case any edge to any other
edge) 1024 PPR (metal disk): ±7.5 arc-min. >1024 PPR (glass disk): ±2.5 arc-min. Format: Two channel quadrature (AB) with optional Index (Z) and complementary outputs Phase Sense: A leads B for CCW shaft rotation as viewed from the shaft end of the encoder
Quadrature Phasing: 90° ± 25° electrical Symmetry: 90° ± 25° electrical Index: 2540 PPR and below: 180° ± 25°
electrical; Greater than 2540 PPR: 90° ± 25° electrical Waveforms: Squarewave with rise and fall times less than 1 microsecond into a load capacitance of 1000 pf
ELECTRICAL
Input Power:
4.5 min. to 26 VDC max. at 80 mA max., not
including output loads
Outputs:
7273 Open Collector: 30 VDC max., 40 mA sink max. 7272 Push-Pull and Differential Line Driver: 40 mA sink or source
Frequency Response: 100 kHz min. Electrical Protection: Overvoltage, reverse
voltage and output short circuit protected Noise Immunity: Tested to EN50082-2 (Heavy Industrial) for Electro Static Discharge, Radio Frequency Interference, Electrical Fast Transients, Conducted and Magnetic Interference
MECHANICAL
Shaft Loading: 40 lbs. radial, 40 lbs. axial Shaft Speed: 5,000 RPM max. Shaft Runout: 0.001" max. TIR Starting Torque: (max at 25 °C) 2.0 oz.-in Moment of Inertia: 9.0 x 10-4 oz–in–sec
OUTPUT FORMAT
Below 2540PPR
Format A
CCW
A
B
Z
Format C
CW
A
B
Z
ENVIRONMENTAL
Operating Temperature: 0 to +70 °C; Storage Temperature: –40 to +90 °C Shock: 50 G’s for 11 milliseconds duration Vibration: 5 to 2000 Hz at 2 G’s
2
Humidity: to 98% without condensation Weight: 4.5 lbs. (2.0 kg) Enclosure Rating: NEMA4X/IP56 (dust proof,
washdown)
2540PPR and Above
Format A
CCW
A
B
Z
Format C
CW
A
B
Z
1.34
by
Code 1: Model
X25
SERIES X25
Ordering Information
To order, complete the model number with code numbers from the table below:
Code 2: Pulses/Rev Code 4: Output
Code 3: Mechanical
HEAVY DUTY
Code 5: Electrical
X25 Explosion
Proof, Shielded Bearings with Shaft Seal
0001 0005 0010 0012 0025 0050 0060 0086 0100 0120 0180 0200 0240 0250 0254 0256 0300
0360 0400 0500 0512 0600 0635 0720 0768 0800 0900 1000 1024 1200 1250 1270 1500
1600 1800 1968 2000 2048 2400 2500 2540 3000 3400 3600 3750 4000 4096 4800 5000
DIMENSIONS
Approximate Dimensions (in inches)
1.272
2.37
0.295 DIA. (4) HOLES
1.2500
1.2495
0 3/8" Shaft 1 1/4" Shaft
1.125
FLAT
0 Single Ended, no index,
Format C
1 Single Ended, with index,
Format C
2 Differential, no Index,
Format C
3 Differential, with index,
Format C
4 Single Ended, with index,
Format A
5 Differential, with index,
Format A
1/2–14 NPTF (5 THREADS MIN.)
0 5-26V in; 5-26V Open
Collector with 2.2k Pullup out
1 5-26V in; 5-26V Open
Collector out
2 5-26V in; 5V Totem
Pole out
3 5-26V in; 5V Line
Driver out
4 5-26V in; 5-26V Line
Driver out
0.75 SQ.
3.375
4" SQ.
1.687
0.3747
SHAFT
0.20
0.30
0.30
1.195
Terminal Board Connections
Z Z C +V
BB
Screw terminals with pressure plates that accept #14 AWG to #22 AWG.
A GA
1.85
4.80
5.65
TB1
TB2
1.35
Loading...