Dynamic Cooking Systems ES36 User Manual

Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
www.dcsappliances.com p. 888-936-7872
VENTILATION PRODUCT DIMENSIONS
ES30, ES36, VS30, VS36, VS1236 & VS48
EURO VENTHOOD/ WALL MOUNT VENTHOOD
PRODUCT DIMENSIONS (INCHES)
VS30
VS36
VS1236
VS48
A
Duct cover accessory overall width 29 –
7
/
8
35 –
7
/
8
29 –
7
/
8
35 –
7
/
8
47 –
7
/
8
B
Duct cover accessory overall height 6” or 12” 6” or 12” 6” or 12” 6” or 12” 6” or 12”
C
Duct cover accessory overall depth 12” 12” 12” 12” 12”
D
Center of exhaust opening from side of hood 14 –
15
/
16
17 –
15
/
16
14 –
15
/
16
17 –
15
/
16
23 –
15
/
16
E
Center of exhaust opening from rear of hood 6” 6” 6” 6” 6”
F
Overall height of product 12” 12” 18” 18” 18”
G
Overall depth of product 23” 23” 25” 25” 25”
H
Overall width of product 29 –
7
/
8
35 –
7
/
8
29 –
7
/
8
35 –
7
/
8
47 –
7
/
8
A
C
B
D
E
F
G
H
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
www.dcsappliances.com p. 888-936-7872
I
A
C
D
E
F
G
H
I
J
B
Bottom of cabinet or soffit
Cabinet
CL
Vertical discharge
Cutout width VS30=30” VS36/VS1236=36” VS48=48”
1 –
1
/2” Dia. holes horizontal conduit options
1 –
1
/2” Dia. holes vertical conduit options
VENTILATION CABINETRY DIMENSIONS
ES30, ES36, VS30, VS36, VS1236 & VS48
EURO VENTHOOD
ES30
A
Bottom of cabinet/soffit depth 12” MIN
B
Distance from rear wall to center of exhaust cutout
6”
C
Diameter of exhaust cutout 10”
D
Distance from rear wall to center of hole for conduit running vertically
6 –
3
/
4
E
Optional hole location for conduit running vertically
1 –
7
/
8
F
Distance from right side of cutout to center of hole for conduit running vertically
5 –
3
/
4
G
Distance from bottom of cabinet to center of hole for conduit running horizontally
5 –
7
/
8
H
Optional hole location for conduit running horizontally
1 –
7
/
8
I
Distance from right side of cutout to center of hole for conduit running horizontally
5 –
1
/
8
A
C
D
E
F
G
H
I
B
Bottom of cabinet or soffit
Cabinet
CL
Vertical discharge
Cutout width ES30=30” ES36=36”
1 –
1
/2” Dia. holes horizontal conduit options
1 –
1
/2” Dia. holes vertical conduit options
WALL MOUNT VENTHOOD
VS30/VS36
VS48/
VS1236
A
Bottom of cabinet/soffit depth 12” MIN
B
Distance from rear wall to center of exhaust cutout
6”
C
Width of cutout 11”
D
Depth of cutout 11”
E
Distance from rear wall to center of hole for conduit running vertically
6 –
3
/
4
F
Optional hole location for conduit running vertically
1 –
7
/
8
G
Distance from right side of cutout to center of hole for conduit running vertically
5 –
3
/
4
H
Distance from bottom of cabinet to center of hole for conduit running horizontally
8 –
3
/
8
I
Optional hole location for conduit running horizontally
1 –
7
/
8
J
Distance from right side of cutout to center of hole for conduit running horizontally
5 –
1
/
8
Loading...