A
Overall depth of product 28” 28”
Distance between countertop level and top surface of product (excluding grates)
5
/
16
5
/
16
C
Height of product 8 –
5
/
16
8 –
5
/
16
D
Depth of product (control panel projecting from cabinet face) 24” 24”
E
Depth of control panel 2 –
1
/
2
2 –
1
/
2
F
Overall width of product 47 –
7
/
8
35 –
7
/
8
PROFESSIONAL COOKTOP PRODUCT DIMENSIONS
CPU-48 Models & CPU-36 Models
A
B
C
D
E
F
Left Side View
Front View
Countertop level
Cabinet face for installation with projecting control panel
Cabinet face for installation with flush control panel
1 –
19
/
32
“ To center line
of gas inlet
Product dimensions and specifications are listed as a guide only. For complete installation instructions and specifications, refer to the product Use & Care Guide/Installation Instructions available at www.dcsappliances.com
www.dcsappliances.com p. 888-936-7872
CABINETRY DIMENSIONS (INCHES)
CPU-48
Models
CPU-36
Models
A
Min. Width of cabinetry opening 48” 36”
Maximum depth from wall to cabinet face 24 ” or 26 –
1
/
2
”* 24 ” or 26 –
1
/
2
”*
C
Height from bottom of cabinet cutout to counter surface 8” 8”
D
Width of electrical and gas supply area 17” 7”
* 24” for installation with projecting control panel, 26 –
1
/
2
” for installation with flush
control panel.
PROFESSIONAL COOKTOP CABINETRY DIMENSIONS
CPU-48 Models & CPU-36 Models
!
A
B
C
D
Min. 48” wide hood for 48” models Min. 36” wide hood for 36” models
30” Min. 36” Min. for best smoke elimination
18” Min.
2”
16”
Cooking Surface
Electrical and Gas Supply
12” Min. to combustible material
,
each side
13” Max.
CAUTION 36” Min. to combustible material
, from cooking surface
As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition).The horizontal surfaces of the cooktop trim must not be below countertop level.
30"
12" Min. to Combustibles without Backguard
15/16"
12"
Wall Mount Low Backguard
Base Cabinet
Wall Mount Full Backguard
36” Min. to Combustibles
36” Min. to Combustibles
Base Cabinet
A B
26 – 1/2
As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition).