Dyna-Glo RMC-LPC25DGP, RMC-LPC80DG, RMC-LPC25DGD, RMC-LPC25DGP-01, RMC-LPC80DGD User's Installation, Operation And Maintenance Manual

...
C US
Propane Construction Heater
RMC-LPC25DG/DGD/DGP/DGP-01 & LPC25 (PROPANE, 25,000 BTU/hr) RMC-LPC80DG/DGD/DGP/DGP-01 (PROPANE, 80,000 BTU/hr) RMC-LPC80C/L/L-01 (PROPANE, 80,000 BTU/hr) RMC-LPC200L/DG/DGP/DGP-01 (PROPANE, 200,000 BTU/hr)
ANS Z83.7-2011 CSA 2.14-2011
Adequate ventilation must be provided.
GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302
CALIFORNIA PROPOSITION 65:
Fuels used in gas or oil fired appliances and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.
Questions, problems, missing parts? Before returning to your retailer, call our customer
4:30 service department at 877-447-4768 pm CST, Monday – Friday
8:30 a.m. –
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
www.ghpgroupinc.com.
IMLPCDG - HCQ
For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com 2
Illustration RMC-LPC80 Series...................................................................
Illustration RMC-LPC25 Series....................................................................
Illustration RMC-LPC200 Series.................................................................
RMC-LPC25Series / RMC-LPC80 Series..................................
RMC-LPC200 Series...............
WARNING: CONSTRUCTION HEATERS ARE NOT FOR USE IN GARAGES IN CANADA.
WARNI NG
: Using this heater in a residential garage requires that the heater is
positioned so that it is protected against any possible damage by a moving vehicle, etc. It must be positioned so that the base of the heater is no less than 18 in (450 mm) above
surface. Do not place it on a chair, ladder, etc. Raising the heater will reduce BUT NOT
stored or accidentally spilled. If the smell of gasoline is present, DO NOT operate this heater until the area has been properly ventilated.
WARNING: Fire, burn, inhalation and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combustibles or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals.
WARNING: Not for home or recreational vehicle use.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com 3
The heater is designed for use as a construction heater in accordance with ANSI Z83.7, CSA 2.14. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advised you about these. The primary purpose of construction heaters is to provide temporary heating of building under construction, alteration or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.
CLEARANCE TO COMBUSTIBLES:
LPC25 Series
LPC80 Series
LPC200 Series
The heater must be located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.
Minimum MinimumMaximum Maximum
(lb/h)
0.7
(0.32 kg/h)
1.16
(0.53 kg/h)
2.32
(1.05 kg/h)
3.71
(1.68 kg/h)
2.32
(1.05 kg/h)
9.28
(4.21 kg/h)
11.7 x 12.87
(29.69 x 32.79 cm)
15.9 x 18.3
(40.41 x 46.99 cm)
15.9 x 26.2
(40.41 x 66.49 cm)
.196
(4.98 mm)
.196
(4.98 mm)
.196
(4.98 mm)
2 ft. (60 cm) 2 ft. (60 cm) 3 ft. (91 cm)
4 ft. (1.22 m) 5 ft. (1.52 m) 6 ft. (1.82 m)
(37.8 °C).
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
For Technical Support or Troubleshooting, Call: 1-877-447-4768 www.ghpgroupinc.com 4
WARNING: Provide at least a 2½ square feet (.23 square meters) opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
WARNING: Provide at least a 6 square feet (.56 square meters) opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
(100 lb.)
Use this heater only with a propane vapor withdrawal supply system. Installation must conform to local codes or, in the absence of local codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1. Your local library or fire department will have this booklet.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
60 °F (15.56 °C) 40 °F (4.44 °C) 32 °F (0 °C) 20 °F (-6.67 °C) 10 °F (-12.22 °C) 0 °F (-17.78 °C)
2.5 ft2 (.23 m2) 6 ft2 (.56 m2)