Dynabrade Dynorbital 57610, Dynorbital 57611 User Manual

95626 Retaining Ring
01206 Bearing
54679 Rear Bearing Plate
95865 Line-up Pin
54670
Cylinder Assembly (Inc. 95865 Line-up Pin)
54674 Blade (5)
54671 Rotor
54680
Front Bearing Plate
02695 Bearing
56046 Lock Ring
54672 Motor Shaft
54673 Rotor Key
54685 Retainer
57398 Gear
96017 V-Ring
01211 Washer (4)
01788 Screw (4)
56052 Bearing
1
96129 Spacer Pak (3)
95898 Screw
56236 Hook and Loop Pad
54627 Mounting Plate
01494 Inlet Bushing
96123 Screw
57382 Gasket
95887 Screw
** 57396 Valve Stem
97010 Screw (4)
57343 Speed Regulator
54194 Muffler Cap
(Non-Vac Only)
54195 Muffler (3)
(Non-Vac Only)
01017 Pin
95558 Retaining Ring
57346 Gasket
* 57344 Lever
01024 O-Ring
97010 Screw (5)
95886 Washer (5)
54628 Counter Balance
57362 Gasket
95886 Washer (4)
97010 Screw (2)
01211 Washer (2)
95955 Water Hose
95343 Set Screw
54199
Muffler Seat
(Non-Vac only)
KEY
L
T
Loctite/Hernon:
L
2
= Loctite #271
Torque: N•m x 8.85 = In. - lbs.
T
2
= 2.82 N•m, T3= 3.38 N•m,
T
4
= 12.42 N•m, T5= 34 N•m,
T
6
= 23 N•m
T
6
L
2
T
3
T
4
L
2
L
2
T
3
T
2
L
2
T
2
L
2
T
5
L
2
95886 Washer (4)
01211 Washer (4)
L
2
Models:
57610 – Basic Wet 57611 – Deluxe Wet
Air Powered , Random Orbital Sander, 10,000 RPM
Parts Page Reorder No. PD96•86
Effective December, 1996
8" Wet Dynorbital
®
Random Orbital Sander
Always operate, inspect and maintain this tool in accordance with the Safety Code for portable air tools (ANSI B186.1) and any other applicable safety codes and regulations. Please refer to Dynabrade's Warning/Safety Operating Instructions for more complete safety information.
01468 Spring
95816 Air Line
95956 Cuff
95958 Over Hose
95717 Hose Clamp
95962 Male
Disconnect
95963 Female
Disconnect
95965 Val ve
95964 Hose Bib
57395 Overskirt
Handle 57361 - Basic
57652 - Deluxe
01472 Tip Valve
01464 Seal
* 01089 Optional Safety-lock Lever. **57375 Valve Stem (For use in with 01089 Safety-lock Lever)
See page 2 for Important Operating, Maintenance and Safety Instructions.
Shaded parts included with deluxe models only.
57599 Val ve
95074 Fitting
Adapter 57373 - Basic
57651 - Deluxe
1
This spacer pak may be included in your tool.
(If so it must be retained and replaced during disassembly.)
Housing
57653 - Basic 57654 - Deluxe
01678 Screw (3)
Important Operating, Maintenance and Safety Instructions
Carefully read all instructions before operating or servicing any Dynabrade® Abrasive Power Tool. Warning: Hand, wrist and arm injury may result from repetitive work motion and overexposure to vibration. Important: All Dynabrade air tools must be used with a Filter-Regulator-Lubricator to maintain all warranties.
Operating Instructions:
Warning: Eye, face and body protection must be worn while operating power tools. Failure to do so may result in serious injury or death.
Follow safety procedures posted in workplace.
1. With power source disconnected from tool, securely fasten abrasive/sanding pad on tool.
2. Connect power source to tool. Be careful not to depress throttle lever in the process.
3. Check tool speed with tachometer. If tool is operating at a higher speed than the RPM marked on the tool or operating improperly, the tool
should be serviced to correct the cause before use.
4. To avoid the danger of contaminating the workpiece from the lubricating oils permeating the air or sanding dust, it is recommended that this machine be hooked up to a central vacuum system or one of our unique vacuum systems that gather all such contaminants in a paper or cloth dust bag. This self contained vacuum system is highly efficient and convenient to use since it does not need to be attached to a separate vacuum system and is as mobile as the machine itself.
Maintenance Instructions:
Products offered by Dynabrade should not be converted or otherwise altered from original design without the expressed written consent from Dynabrade, Inc.
1. All Dynabrade air motors should be lubricated. Dynabrade recommends one drop of air lube per minute for each 10 SCFM (example : if the tool specification state 40 SCFM, set the drip rate of your filter-lubricator at 4 drops per minute). Dynabrade Air Lube (P/N 95842: 1pt. 473ml.) is recommended.
2. An air line filter-regulator-lubricator must be used with this air tool to maintain all warranties. Dynabrade recommends the following 11289 Air Line Filter-Regulator-Lubricator — Provides accurate air pressure regulation, two-stage filtration of water contaminants and
positive-drip lubrication of pneumatic components. Operates 28 CFM @ 90 PSI has 3/8" NPT female ports.
3. Frequent drainage of water traps in air lines is recommended.
4. Some silencers on air tools may clog with use. Clean and replace as required.
5. A motor tune-up kit (P/N 96200) is available which includes assorted parts to help maintain motor in tip-top shape.
Safety Instructions:
1. Warning:Eye, face and body protection must be worn while operating power tools. Failure to do so may result in serious injury or death
Follow safety procedures posted in workplace.
2. Important: User of tool is responsible for following accepted safety codes such as those published by the American National Standards Institute
3. Tool RPM must never exceed abrasive/sanding pad RPM rating, regardless of tool capacity.
4. Operate machine for 30 seconds before application to workpiece to determine if machine is working properly and safely before work begins.
5. Always disconnect power supply before changing abrasive or making machine adjustments.
6. Inspect abrasives and sanding pads for damage or defects prior to and during operation of tool.
7. Please refer to Dynabrade’s Warning/Safety Operating Instructions Tag (Reorder No. 95903) for more complete safety information.
8. Warning: Hand, wrist and arm injury may result from repetitive work, motion and overexposure to vibration.
Notice
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality pneumatic motors
can most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor bearings causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is contingent upon proper use of our tools and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of lubrication during the use of this tool.
Note: To order replacement parts specify the model and serial number of your machine.
2
Full One Year Warranty
Following the reasonable assumption that any inherent defect which might prevail in a product will become apparent to the user within one year from the date of purchase, all equipment of our manufacture is warranted against defects in workmanship and materials under normal use and service. We shall repair or replace at our factory, any equipment or part thereof which shall, within one year after delivery to the original purchaser, indicate upon our examination to have been defective. Our obligation is contingent upon proper use of Dynabrade tools in accordance with factory recommendations, instructions and safety practices. It shall not apply to equipment which has been subject to misuse, negligence, accident or tampering in any way so as to affect its normal performance. Normally wearable parts such as bearings, contact wheels, rotor blades, etc., are not covered under this warranty.
Loading...