Dynabrade Auto File II 18100, Auto File II 18101 Safety, Operation And Maintenance

Auto File
Abrasive Belt Tool
Safety, Operation and Maintenance – Save This Document and Educate All Personnel
Parts Page Reorder No. APD13•04
Effective July, 2013
18100 - Supersedes APD08•06 18101 - Supersedes APD06•06
WARNING
Read and understand tool manual before work starts to reduce risk of injury to operator, visitors, and tool.
Ear protection to be worn when exposure to sound, exceeds the limits of applicable Federal, State or local statues, ordinances and/or regulations.
Practice safety requirements. Work alert, have proper attire, and do not operate tools under the influence of alcohol or drugs.
Air line hazard, pressurized supply lines and flexible hoses can cause serious injury. Do not use damaged, frayed or deteriorated air hoses and fittings.
Eye protection must be worn at all times, eye protection to conform to ANSI Z87.1.
Respiratory protection to be used when exposed to contaminants that exceed the applicable threshold limit values required by law.
Some dust created by sanding, grinding, drilling, and other construction activities contain chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
• Lead from lead-based paints
• Crystalline silica from bricks and cement and other masonry products
• Arsenic and chromium from chemically treated lumber Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
DO NOT USE Tool for Anything Other Than Its Intended Applications.
Training: Proper care, maintenance, and storage of your air tool will maximize tools performance and reduce chance for accident. Employer's Responsibility: Provide operators with safety instructions and training for safe use of tools and accessories.
Report to Your Supervisor any Condition of the Tool, Accessories or Operation you Consider Unsafe.
Tool Intent: Auto File II are used for grinding, deburring, blending and polishing on various materials. Tool accepts optional
abrasive belts that are 1/8"–3/4" wide and up to 20-1/2" long.
SAFETY and OPERATING INSTRUCTIONS
Carefully Read and Understand the General and Sander sections found in Tool Safety and Operating Guidelines (PN00001676) Before Handling or Using Tool.
Carefully Read all instructions before operating or servicing any Dynabrade®Abrasive Power Tool. Products offered by Dynabrade are not to be modified, converted or otherwise altered from the original design.
Model RPM Belt Size
18100
20,000 1/2" W x 18" L
18101
20,000 3/4" W x 20-1/2" L
SANDER
II
Model 18100
For Serial No. 13F2796A and Higher
2
Filter
Regulator
Lubricator
90 PSIG (6.2 Bar)
To Tool Station
Ball
Valve
Ball
Valve
Filter
Regulator
Lubricator
Air Flow
Drain Valve
Drain Valve
Air Tool
Air Compressor
and Receiver
Drain Valve
Air Hose
90 PSIG MAX
(6.2 Bar)
Air Flow
Refrigerated
Air Dryer
• Dynabrade Air Power Tools are designed to operate at 90 PSIG (6.2 Bar) maximum air pressure at the tool inlet, when the tool is running. Use recommended regulator to control air pressure.
• Ideally the air supply should be free from moisture. To facilitate removing moisture from air supply, the installation of a refrigerated air dryer after the compressor and the use of drain valves at each tool station is recommended.
AIR SYSTEM
Closed Loop Pipe System, Sloped in Direction of Air Flow
1 DROP/MIN.
20 SCFM
LUBRICATOR SETTING
MAINTENANCE INSTRUCTIONS
Important: To keep tool safe, a Preventative Maintenance Program is recommended. The program should included inspection of the tool and all related accessories and consumables, including air lines, pressure regulators, filters, oilers, etc. refer to CAGI B186.1 for additional maintenance information. If accessory or tool breakage occurs, investigate failure to determine the cause and correct before issuing tool for work. Use the following schedule as a starting point in developing a Preventative Maintenance Program. If tool does not operate properly (RPM, Vibration, Start/Stop) after these scheduled checks or at any time, the tool must be repaired and corrected before returning tool to use.
INSTALLATION
• To ensure long life and dependable service, use a Closed Loop Air System and Filter-Regulator-Lubricator as diagramed below.
• Each tool should have its own dedicated hose connected to an air supply manifold. Quick disconnects should be installed at the manifold in an effort to reduce contamination into the tool.
• It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility of misuse due to unclean air, wet air or insufficient lubrication. Dynabrade recommends the following: 10681 Air Line Filter-Regulator-Lubricator — Provides accurate air pressure regulation, two-stage filtration of water contaminants and micro-mist lubrication of pneumatic components.
• Dynabrade recommends one drop of air lube per minute for each 20 SCFM (example: if the tool specification states 40 SCFM, set the drip rate on the filter-lubricator to 2 drops per minute) Dynabrade Air Lube (P/N 95842: 1pt/473ml) is recommended.
MAINTENANCE SCHEDULE
Daily (every 8 hours):
• Inspect tool and accessories for damage or broken parts. Replace items as necessary to ensure proper operation and safety.
• Lubricate motor as recommended. Use Dynabrade Air Lube (P/N 95842: 1pt/473ml) 10W/NR. (1 Drop per minute of air lube per 20 SCFM.)
• Check air line pressure with a gage. (MAX. 90 PSIG or 6.2 Bar operating pressure at the air inlet of the tool.)
• Right angled gear and wick system through gear case grease fitting with 3 plunges of gear oil (P/N 95848) and grease gun (P/N 95541). (Prime grease gun prior to greasing.)
• Check tool for proper operation: If operating improperly or demonstrates unusual vibration, the tool must be serviced and problem corrected before further use.
Every 20 Hours or Once a Week Which Ever Comes First:
• Check free speed of tool without the abrasive accessory mounted. Measure RPM (speed) with tachometer and with air pressure set at 90 PSIG while the tool is running. If a governed tool is operating at a higher speed than the RPM marked on the tool housing, the tool must be serviced and corrected before use. A non-governed tool may exceed the RPM marked on the tool by 10% when operated at free speed with no accessories.
• If tool is running fast look for worn, damaged or missing governors, air control rings and silencers. Special care must be taken when servicing
governors and speed control devices. Injection molded governor assemblies are non-serviceable and must be replaced.
• If tool is running slow look for clogged inlet screen, air stream, silencer(s) or a malfunctioning governor (see concerns for servicing governors). Service as required.
Every 50 Hours:
• Lubricate planetary gears through gear case grease fitting with 3 plunges of grease (P/N 95542) and grease gun (P/N 95541). (Prime grease gun prior to greasing.)
REPAIR
• Use only genuine Dynabrade replacement parts to ensure quality. To order replacement parts, specify Model#, Serial# and RPM of your air tool.
• Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters, ketones, chlorinated hydrocarbons or nitro carbons.
• DO NOT clean or maintain tools with chemicals that have a low flash point (example: WD-40
®
).
• Motor Tune-Up Kit are available (when applicable) which includes high wear and medium wear motor parts.
• Air tool markings must be kept legible at all times, if not, reorder housing and replace. User is responsible for maintaining specification information.
• After maintenance is performed on tool, add a few drops of Dynabrade Air Lube (P/N 95842) to the tool inlet and start the tool a few times to lubricate air motor. Verify RPM (per 20 hr maintenance schedule), vibration and operation.
HANDLING & STORAGE
• Use of tool rests, hangers and/or balancers is recommended.
• Protect tool inlet from debris (see Notice).
• DO NOT carry tool by air hose or near the tool throttle lever.
• Store accessories in protective racks or compartments to prevent damage.
• Follow the handling instructions outlined in the operating instructions when carrying the tool and when changing accessories.
• Protect accessories from exposure to water, solvents, high humidity, freezing temperature and extreme temperature changes.
END OF USE/ DISPOSAL
When tool has reached its end of useful service, disassemble tool into its primary components (i.e. steel, aluminum and plastic part) and recycle or discard per local, state and/or federal regulations as to not harm the environment.
NOTICE
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality pneumatic motors can most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor bearings causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is contingent upon proper use of our tools and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of lubrication during the use of this tool.
ITEM P/N DESCRIPTION QTY.
1
11203 11287
CONTACT ARM - 18100 CONTACT ARM - 18101
AR
2
18138 18139
HOUSING ASSEMBLY - 18100 HOUSING ASSEMBLY - 18101
AR
2.1 11040 SPRING 1
2.2 96334 PLUG 1
2.3 15308 GUIDE POST 1
2.4 15306 TENSION ARM 1
2.5 95426 SPRING 1
2.6 15309 DUST COVER 1
2.7 15307 TENSION SHAFT 1
2.8 15312 BELT GUARD ASSEMBLY 1
2.8.1 15329 SCREW 1
2.8.2 15310 BELT GUARD 1
2.9 96335 NUT 1
2.10
18136 18137
BELT HOUSING - 18100 BELT HOUSING - 18101
AR
2.10.1 95442 SCREW 2
2.10.2
18133 18134
LABEL - 18100 LABEL - 18101
1
2.11 95311 SCREW 1
2.12 40029 MOTOR LOCK 1
2.13 95217 SCREW 1
3 95218 KNOB 1
4 40375 DRIVE WHEEL 1
5 18851 MOTOR ASSEMBLY 1
5.1 18864 LOCK RING 1
5.2 18863 FELT SILENCER 1
5.3 18862 AIR CONTROL RING 1
5.4 18861 ROTOR NUT 1
5.5 01007 BEARING 1
5.6 18874 FRONT BEARING PLATE 1
5.7 18821 PIN 3
5.8 18825 SPACER 1
5.9 18870 ROTOR 1
5.10 18823 VANE SET (4/PKG.) 1
5.11 18822 CYLINDER 1
5.12 18820 REAR BEARING PLATE 1
5.13 01015 BEARING 1
5.14 18869 GASKET 1
5.15 18865 AIR MOTOR HOUSING 1
5.16 18867 PLUG 1
5.17 18446 LOCK RING 1
5.18 18866 WASHER 1
5.19 18400 THROTTLE HOUSING 1
5.20 18420 VALVE SCREW 1
5.21 18419 O-RING 1
5.22 18418 O-RING 1
5.23 18417 REGULATOR 1
5.24 18416 SPRING 1
5.25 18415 O-RING 1
5.26 18413 VALVE STEM 1
5.27 18414 O-RING 1
5.28 18412 BUSHING 1
5.29 18411 STOP ROD 1
5.30 18410 SPRING 1
5.31 18408 THROTTLE LEVER 1
5.32 18409 PIN 1
5.33 18407 PIN 1
5.34 18403 O-RING 1
5.35 18868 EXHAUST PLUG 1
5.36 18405 AIR INLET 1
5.37 18439 FILTER 1
Auto File
II
Complete Assembly
Adhesive: A8= Loctite®#567
A
10
= Loctite®#243
Oil: O1= Air Lube
O
G
A
T
T
x
Always follow adhesive manufacturers
cleaning and priming recommendations.
Torque: N•m x 8.85 = lbin.
X = Torque Value (N•m)
KEY
Grease: G2=
Loctite®#771
Model
18100
For 18" L Belts
18101
For 20-1/2" L Belts
3
5.2
5.3
T
3.5
T
34
T
45
T
17
4
5.1
5.4
5.5
1
2.9
2.8.1
2.1
T
3
2.2
2.3
2.4
3
A
10
A
10
G
2
G
2
T
3
G
2
2.5
2.6
2.7
2.8.2
2.10
2.12
2.13
2.11
5.7
5.8
O
1
A
8
A
8
A
8
5.9
5.10
5.11
5.12
5.13
5.14
5.15
5.17
5.18
5.19
AR – “As Required”
5.16
2.10.2
2.10.1
5.6
5.7
A
8
T
23
O
1
5.27
5.25
5.20
5.22
5.24
5.34
5.33
5.35
5.36
5.37
5.26
5.23
5.21
5.28
5.29
5.30
5.31
5.32
Loading...
+ 5 hidden pages