Dynabrade 61300, 61301, 61302, 61303, 61304 Operating Manual

...
Reorder No. PD05.20
Supersedes PD04.21
IMPORTANT SAFETY INSTRUCTIONS
1. Components used in packaging (ie. plastic bags) can be
dangerous keep away from children and animals.
2. The unit is for DRY USE ONLY and must be stored in a dry room.
3. The use of this machine for anything not specified in this
manual may be dangerous and must be avoided.
5. The equipment should be correctly assembled before use.
6. Ensure that power socket is correct for the machine.
7. Check the voltage indicated on the rating plate is the same as
the supply voltage.
8. These machines are not designed for picking up health endangering dusts or inflammable/explosive substances.
9. Never leave the equipment unattended while in use.
10. Never use this equipment to pick up any kind of liquid.
11. Never carry out any maintenance on the machine without first
disconnecting from the main supply, if the machine is to be left unattended the supply should also be terminated.
12. The main supply cable should not be used to pull or lift the machine.
13. The machine should never be emersed in water or a pressure jet of water used for cleaning.
14. Periodically examine the main cable and machine for damage. If any damage is found contact your service centre for repair.
15. Should extension cables be used, ensure that the cable rating is suitable for use with the equipment. Do not use the cable coiled as this could result in a voltage drop or overheating. Keep dry at all times.
16. This equipment should NOT be used to pick up water from containers, lavatories, tubs, etc.
17. Service and repairs must be carried out by qualified personnel only. Replacement parts for the machine must be manufacturers original spare parts only.
18. The manufacturer cannot be held responsible for any damage/injury caused to persons or property, because of the incorrect use of the machine due to procedures being used which are not specified in this instruction manual.
These Portable Vacuum Systems have been developed as a safe, portable, mobile, yet powerful industrial tool for commercial use. To ensure that this quality equipment is properly used and maintained to its full capability, please carefully read the following safety instructions and operating procedures before commencement of the operation.
When operating this equipment, basic precautions should always be strictly followed
including the instructions listed below:
M” CLASS DRY VACUUM
When employed in accordance with their intended use, the industrial vacuum cleaners described in these operating instructions are suitable for picking up
non-flammable, dry dusts. They correspond to dust class “M” in accordance to:
EN 60335-2-69. By SLG, Germany
61300 (9.9 gal./36 ltr.) 120v-60Hz (US) 61301 (17 gal./64 ltr.) 120v-60Hz (US) 61302 (9.9 gal./36 ltr.) 230v-50Hz (UK) 61303 (17 gal./64 ltr.) 230v-50Hz (UK) 61304 (9.9 gal./36 ltr.) 110v-60Hz (UK)
61305 (17 gal./64 ltr.) 110v-60Hz (UK) 61306 (9.9 gal./36 ltr.) 230v-50Hz (EUR) 61307 (17 gal./64 ltr.) 230v-50Hz (EUR) 61308 (9.9 gal./36 ltr.) 230v-50Hz (OUS) 61309 (17 gal./64 ltr.) 230v-50Hz (OUS)
Portable Vacuum System
Operating Manual
ASSEMBLY INSTRUCTIONS
1. While opening the carton, carefully inspect outside of the
carton for any sign of transportation damage, and if so, notify your shipper immediately.
2. Open carton and remove hoses, hose connectors and other accessories.
3. Lay carton on its back and wheel the unit out.
4. Remove all packing, release the unit and remove
Motorhead/Vacuum Head Assembly to make sure no packing materials are left inside the unit.
5. Check to make sure the filter is seated firmly. If not, tighten at base of filter unit.
7. Remove the vacuum hose assembly. Note that the air supply tube (the smaller of the two) protrudes at both ends and is longer than the vacuum hose.
8. Connect quick coupler male end to air outlets located on vacuum head assembly.
9. Insert vacuum hoses.
10. Connect air supply to air inlet fitting (1/4" NPT female threads)
located at the back side of Motorhead. Air pressure should be adjusted according to the pressure requirement of the air tools
you are using. Do not exceed 150 PSIG (10.3 kg/cm2). Some pressure drop is unavoidable between the main air supply and the air tools due to internal flow resistance in a long air hose.
Air pressure of 20 to 30 PSIG (1.4 to 2.0 kg/cm2) higher than the air pressure specified for the air tool being used is recommended.
The installation of a Dynabrade Filter-Regulator-Lubricator (FRL Part No. 11411) is highly recommended to protect the unit and the air tools.
Where it is critical to avoid shocks or sparks caused by static electricity, an air supply hose which is electrically conductive and ground must be used.
11. All Dynabrade Vacuum Models come with a sample dust bag.
Install bag inside main body. Make sure that vacuum connection tube protrudes through the hole in the bag.
12. Order dust bags (Part No. 64682) before you run out of them.
13. Return Motorhead/Vacuum Head Assembly to the unit and lock
the two rim clamps to secure Motorhead/Vacuum Head Assembly in position.
14. Connect your Dynabrade air tool or accessory and you are now ready for working with the Dynabrade Portable Vacuum System.
CAUTION
THIS IS A PRECISION PIECE OF EQUIPMENT designed for dust extraction to keep your ENVIRONMENT and your REPUTATION “DUST-FREE.” Read operating instructions before using Dynabrade Portable Vacuum System and be thoroughly conversant with safety precautions in your locality.
Refer to the drawing and parts list for the name and location of parts.
OPERATING INSTRUCTIONS
1. Always wear safety glasses and any other safety items
required by law.
2. The vacuum system will operate by an on/auto/manual switch located on the front of the Motorhead/Vacuum Head Assembly. This switch must be turned on to activate the Motorhead.
3. VACUUM SPEED CONTROL: Unit is equipped with a rheostat motor control. Infinitely adjustable speed allows suction regulation for wide range of tools.
4. ELECTRONIC THERMAL PROTECTION DEVICE: Unit is equipped with a overload prevention system. If this feature is activated a 20 MIN. COOL DOWN PERIOD inhibits use. After a complete 20 min. cool down period has passed the Electronic Thermal Protection Device will RE-SET automatically and the unit will be on line ready for use.
5. VISUAL WARNING SIGNAL: Unit is equipped with a visual warning (yellow) light to indicate when air velocity falls below 20m/s. Turn off vacuum and replace disposable collection bag. The warning signal will RE-SET automatically and the unit will be ready for use.
The following items should be well-noted for the effective use of the unit.
GROUNDING INSTRUCTIONS
This unit must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
Where it is critical to avoid shocks or sparks caused by static electricity, an electrically conductive and grounded air supply hose must be used.
PAGE 2
WARNING
Grounding by means of a ground wire between both ends of the air supply tubing passing through vacuum hose is recommended.
NEW!