Dynabrade 52225, 52226, 52227, 52288, 52290 Operation, Maintenance And Safety Instructions

...
Air Motor and Machine Parts
Always operate, inspect and maintain this tool in accordance with the Safety Code for portable air tools (ANSI B186.1) and any other applicable safety codes and regulations. Please refer to Dynabrade's Warning/Safety Operating Instructions for more complete safety information.
See reverse side for Accessories and Important Operating, Maintenance and Safety Instructions.
*Optional 01462 Safety Lock Lever assembly available.
52224 – 15,000 RPM, 6mm 52225 – 18,000 RPM, 6mm 52226 – 20,000 RPM, 6mm 52227 – 20,000 RPM, 6mm 52288 – 15,000 RPM, 1/4" 52289– 18,000 RPM, 1/4" 52290– 20,000 RPM, 1/4" 52291– 20,000 RPM, 1/4"
Parts Page Reorder No. PD96•72
Effective November, 1996
.7 Hp/7°/Short Shank/Front Exhaust
Die Grinder
KEY
L
T
O
Loctite/Hernon: L
2
= Hernon #940
Torque: N•m x 8.85 = In. - lbs.
T
2
= 17 N•m, T3= 23 N•m,
T
5
= 45 N•m
G
Oil
Grease
01739 Housing
Left Hand Threads
01558 Collar
01461 Lock Nut
01548 Gasket
01437 Plug
T
4
L
2
01449 Valve Stem
95730 O-Ring
01024 O-Ring
01469 Speed Regulator
(includes O-rings)
Right Hand Threads
01464 Seal 01468 Spring
01472 Tip Valve 01494 Inlet Adapter
95558 Retaining Ring
01448 Lever
12132 Pin
T
3
L
2
O
01121 Shim (3/pkg.) (as required)
01744 Silencer
01008 Bearing Plate01007 Bearing
01057 Blade (4) (4/pkg.)
55021 Rotor
01028 Cylinder
50767 Pin 02649 Bearing
01743 Bearing Plate
01010 Rotor Spacer
50012 Collet Cap50011 Collet Body
O
T
2
T
2
01463 Housing
Please indicate: Model #, Serial #, and RPM when ordering replacement parts.
Collet Insert
50013 - 1/4" 50016 - 6mm
Collet Assembly
50010 - 1/4" 50015 - 6mm
Exhaust Cover
01734 - 15,000 01738 - 18,000 01748 - 20,000
!
WARNING
Important Operating, Maintenance and Safety Instructions
Carefully read all instructions before operating or servicing any Dynabrade® Abrasive Power Tool. Warning: Hand, wrist and arm injury may result from repetitive work motion and overexposure to vibration. Important: All Dynabrade air tools must be used with a Filter-Regulator-Lubricator to maintain all warranties.
Operating Instructions:
Warning: Eye, face and body protection must be worn while operating power tools. Failure to do so may result in serious injury or death. Follow safety
procedures posted in workplace.
1. With power source disconnected from tool, securely fasten abrasive/ accessory on tool.
2. Install air fitting into inlet bushing of tool. Important: Secure inlet bushing of tool with a wrench before attempting to install the air fitting to avoid damaging
valve body housing.
3. Connect power source to tool. Be careful not to depress throttle lever in the process.
4. Check tool speed with tachometer. If tool is operating at a higher speed than the RPM marked on the tool or operating improperly, the tool should be
serviced to correct the cause before use.
Maintenance Instructions:
1. Check tool speed regularly with a tachometer. If tool is operating at a higher speed than the RPM marked on the tool, the tool should be serviced to correct
the cause before use.
2. Some silencers on air tools may clog with use. Clean and replace as required.
3. All Dynabrade air motors should be lubricated. Dynabrade recommends one drop of air lube per minute for each 10 SCFM (example : if the tool specification state 40 SCFM, set the drip rate of your filter-lubricator at 4 drops per minute). Dynabrade Air Lube (P/N 95842: 1pt. 473ml.) is recommended.
4. An air line filter-regulator-lubricator must be used with this air tool to maintain all warranties. Dynabrade recommends the following: 11289 Air Line Filter-
Regulator-Lubricator — Provides accurate air pressure regulation, two-stage filtration of water contaminants and micro-mist lubrication of pneumatic components. Operates 28 CFM @ 90 PSI has 3/8" NPT female ports.
5. Use only genuine Dynabrade replacement parts. To reorder replacement parts, specify the Model #, Serial #, and RPM of your machine.
6. A motor tine-up kit (P/N 96045) is available which includes assorted parts to help maintain motor in peek operating condition.
7. Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters, keytones,
chlorinated hydrocarbons or nitro carbons.
Safety Instructions:
Products offered by Dynabrade should not be converted or otherwise altered from original design without expressed written consent from Dynabrade, Inc.
Important: User of tool is responsible for following accepted safety codes such as those published by the American National Standards Institute (ANSI).
Operate machine for one minute before application to workpiece to determine if machine is working properly and safely before work begins.
Always disconnect power supply before changing abrasive/accessory or making machine adjustments.
Inspect abrasives/accessories for damage or defects prior to installation on tools.
Please refer to Dynabrade’s Warning/Safety Operating Instructions Tag (Reorder No. 95903) for more complete safety information.
Warning: Hand, wrist and arm injury may result from repetitive work, motion and overexposure to vibration.
Notice
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality pneumatic motors can most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor bearings causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is contingent upon proper use of our tools and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of lubrication during the use of this tool.
2
(PD96•72)
One Year Warranty
Following the reasonable assumption that any inherent defect which might prevail in a product will become apparent to the user within one year from the date of purchase, all equipment of our manufacture is warranted against defects in workmanship and materials under normal use and service. We shall repair or replace at our factory, any equipment or part thereof which shall, within one year after delivery to the original purchaser, indicate upon our examination to have been defective. Our obligation is contingent upon proper use of Dynabrade tools in accordance with factory recommendations, instructions and safety practices. It shall not apply to equipment which has been subject to misuse, negligence, accident or tampering in any way so as to affect its normal performance. Normally wearable parts such as bearings, sanding pads, rotor blades, etc., are not covered under this warranty.