Dynabrade 49135, 49430, 49455 Safety, Operation And Maintenance

Page 1
Safety, Operation and Maintenance – Save This Document and Educate All Personnel
PD12.19
Effective May, 2012
WARNING
Read and understand this tool manual before operating your air tool. Follow all safety rules for the protection of operating personnel as well as adjacent areas. Always operate, inspect and maintain this tool in accordance with the American National Standards Institute (ANSI). Safety Requirements for the Use, Care and Protection of Abrasive Wheels – ANSI B7.1, Compressed Air and Gas Institute (CAGI) Safety Code for Portable Air Tools – B186.1, Code of Federal Regulation – CFR 29 Part 1910, International Organization for Standardization (ISO) Hand Held Non-Electric Power Tools – Safety Requirements and applicable State and Local Regulations.
Find The Most Current Offering of Support Documents and Accessories at www.Dynabrade.com
Read and understand tool manual before work starts to reduce risk of injury to operator, visitors, and tool.
Ear protection to be worn when exposure to sound, exceeds the limits of applicable Federal, State or local statues, ordinances and/or regulations.
Practice safety requirements. Work alert, have proper attire, and do not operate tools under the influence of alcohol or drugs.
Air line hazard, pressurized supply lines and flexible hoses can cause serious injury. Do not use damaged, frayed or deteriorated air hoses and fittings.
Eye protection must be worn at all times, eye protection to conform to ANSI Z87.1.
Respiratory protection to be used when exposed to contaminants that exceed the applicable threshold limit values required by law.
Some dust created by sanding, grinding, drilling, and other construction activities contain chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
• Lead from lead-based paints
• Crystalline silica from bricks and cement and other masonry products
• Arsenic and chromium from chemically treated lumber Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
SAFETY and OPERATING INSTRUCTIONS
DO NOT USE Tool for Anything Other Than Its Intended Applications.
Training: Proper care, maintenance, and storage of your air tool will maximize tools performance and reduce chance for accident. Employer's Responsibility: Provide operators with safety instructions and training for safe use of tools and accessories.
Report to Your Supervisor any Condition of the Tool, Accessories or Operation you Consider Unsafe.
Tool Intent: Drills are ideal for drilling holes using 1/4"-28 threaded drill bits or accessories. Vacuum model is intended to capture
drilled debris at the source. Follow all safety guidelines for material being processed/vacuumed.
Carefully Read and Understand the General and Sander/Polisher sections found in Tool Safety and Operating Guidelines (PN00001676) Before Handling or Using Tool.
Carefully Read all instructions before operating or servicing any Dynabrade®Abrasive Power Tool. Products offered by Dynabrade are not to be modified, converted or otherwise altered from the original design.
Model Drill Type RPM
49135
Central Vacuum 3,200
49430
Standard
3,200
49455
Slow-Speed 950
.4 hp Drill
Angle Head, 1/4"-28 Thread
DRILL
Model 49430
Page 2
MAINTENANCE INSTRUCTIONS
Important: To keep tool safe, a Preventative Maintenance Program is recommended. The program should include inspection of the tool and all related accessories and consumables, including air lines, pressure regulators, filters, oilers, etc. (refer to CAGI B186.1 for additional maintenance information). If accessory or tool breakage occurs, investigate failure to determine the cause and correct before issuing tool for work. Use the following schedule as a starting point in developing a Preventative Maintenance Program. If tool does not operate properly (RPM, vibration, start/stop) after these scheduled checks or at any time, the tool must be repaired and corrected before returning tool to use.
INSTALLATION
• To ensure long life and dependable service, use a Closed Loop Air System and Filter-Regulator-Lubricator (FRL) as diagramed below.
• Each tool should have its own dedicated hose connected to an air supply FRL. Quick disconnects should be installed at the FRL in an effort to reduce contamination into the tool. Securely affix all fittings and hose assemblies.
• It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility of misuse due to unclean air, wet air or insufficient lubrication. Dynabrade recommends the following: 10681 Air Line Filter-Regulator-Lubricator — Provides accurate air pressure regulation, two-stage filtration of water contaminants and micro-mist lubrication of pneumatic components.
• Dynabrade recommends 1 drop of air lube per minute for each 20 SCFM (example: if the tool specification states 40 SCFM, set the drip rate on the filter-lubricator to 2 drops per minute). 95842 Dynabrade Air Lube is recommended.
MAINTENANCE SCHEDULE
Maintenance schedules depend on the type and style of tool. Refer to page 3 to reference symbols associated with specific maintenance items/areas. Match maintenance schedules accordingly. See page 4 for any additional maintenance information.
Note: Turbine style air motors do not require oil.
Daily (every 8 hours):
• Inspect tool and accessories for damage or broken parts. Replace items as necessary to ensure proper operation and safety.
Lubricate motor as recommended. Use 95842 Dynabrade Air Lube (10W/NR). Apply 1 drop/minute of air lube per 20 SCFM.
• Check air line pressure with a gage. (MAX. 90 PSIG or 6.2 Bar operating pressure at the air inlet of the tool.)
Lubricate wick system and right angle gears through gear case fitting. Apply 3 plunges of 95848 Gear Oil. Use 95541 Lubricant Gun (Prime lubricant gun before use).
• Check tool for proper operation: If operating improperly or demonstrates unusual vibration, the tool must be serviced and problem corrected before further use.
Every 20 Hours/Once a Week (which ever comes first):
• Measure RPM (speed) by setting air pressure to 90 PSIG (6.2 Bar) at tool inlet, without accessory mounted, while the tool is running. Using tachometer, check spindle speed of the tool. Unless otherwise stated the
no-load speed may not exceed the rated speed. If tool speed exceeds maximum rated RPM, service as required and correct before use.
• If tool is running too fast: look for worn, damaged or missing governor, air control rings and silencer(s). Service as required.
• If tool is running too slow: look for malfunctioning governor, clogged inlet screen, silencer(s) or air stream. Service as required.
Note: Special care must be taken when servicing governors. Refer to specific tool manual for governor instructions and/or speed control devices. Governor assemblies made from molded plastic components are non-serviceable and must be replaced.
Every 50 Hours:
Lubricate planetary gears through gear case fitting with 3 plunges of 95542 Grease. Use 95541 Lubricant Gun. (Prime lubricant gun before use).
REPAIR
• Use only genuine Dynabrade replacement parts to ensure quality. To order replacement parts, specify Model#, Serial# and RPM of your air tool.
• Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters, ketones, chlorinated hydrocarbons or nitro carbons.
• A Motor Tune-Up Kit is available which includes high wear and medium wear motor parts.
• Air tool markings must be kept legible at all times, if not, reorder housing and replace. User is responsible for maintaining specification information.
After maintenance is performed on tool, add a few drops of 95842 Dynabrade Air Lube to the tool inlet and start the tool a few times to lubricate air motor. Verify RPM (per 20 hr maintenance schedule), vibration and operation.
HANDLING & STORAGE
• Use of tool rests, hangers and/or balancers is recommended.
• Protect tool inlet from debris (see Notice below).
Do Not carry tool by air hose or near the tool throttle lever.
• Store accessories in protective racks or compartments to prevent damage.
• Follow the handling instructions outlined in the operating instructions when carrying the tool and when changing accessories.
• Protect accessories from exposure to water, solvents, high humidity, freezing temperature and extreme temperature changes.
END OF USE/ DISPOSAL
When tool has reached its end of useful service, disassemble tool into its primary components (i.e. steel, aluminum and plastic) and recycle or discard per local, state and/or federal regulations as to not harm the environment.
NOTICE
All Dynabrade air motors use the highest quality parts available and are manufactured to exacting tolerances. Air motor failures are often traced to lack of lubrication or unclean air supply. Compressed air can force dirt and other contaminants into motor bearings causing early failure. Contaminants can score cylinder wall and vanes resulting in reduced efficiency and power. Our warranty obligation is contingent upon proper use of our tools. Air motors which have been subjected to misuse, contaminated air or lack of lubrication will void warranty.
Filter
Regulator
Lubricator
Lubricator Setting
90 PSIG
(6.2 Bar)
Air Flow to Tool Station
Ball
Valve
Ball
Valve
Air Flow
Drain Valve
Drain Valve
Air Tool
Air Compressor and Receiver
Drain Valve
Air Hose
90 PSIG Max.
(6.2 Bar)
Air Flow
Refrigerated
Air Dryer
• Dynabrade Air Power Tools are designed to operate at 90 PSIG (6.2 Bar) maximum air pressure at the tool inlet, when the tool is running. Use recommended regulator to control air pressure.
• Ideally the air supply should be free from moisture. To facilitate removing moisture from air supply, the installation of a refrigerated air dryer after the compressor and the use of drain valves at each tool station is recommended.
CLOSED LOOP AIR SYSTEM
Sloped in Direction of Air Flow
O
W
G
O
2
~
1 Drop/Minute per 20 SCFM
Page 3
3
Models
49135
– Central Vacuum
49430
– Standard
49455
– Slow-Speed
49135
49455
.4 hp Drill
Complete Assembly
ITEM P/N DESCRIPTION QTY.
1 54560 ANGLE HEAD ASSEMBLY 1
1.1 54550 BEARING CAP 1
1.2 54537 BEARING 1
1.3 54549 WORK SPINDLE 1
1.4 54542 BEARING 2
1.5 54536 SHIM PACK (4/PKG) AR
1.6 01041 LUBRICANT FITTING AR
1.7 54547 ANGLE HOUSING 1
1.8 54546 BEVEL GEAR 1
1.9 54541 SPINDLE 1
1.10 54529 SHIM PACK (3/PKG) AR
1.11 95398 BEARING 1
1.12 54540 RETAINING NUT 1 2 54527 LOCK RING 1
3
53451 53454
ADAPTER - 49135/49430
ADAPTER - 49455
1
4 50784 SET SCREW AR 5 01041 LUBRICANT FITTING AR 6 53450 DRIVE SPLINE 1 7 54520 BEARING AR 8 54468 RING GEAR AR
9
50786 50787
PLANETARY CARRIER - 49135/49430
PLANETARY CARRIER - 49455
AR
10
54519 06213
GEAR ASSEMBLY - 49135/49430
GEAR ASSEMBLY - 49455
AR
11 54472 SHAFT AR 12 50788 SPACER - MDL 49455 1 13 53150 PINION - MDL 49455 1 14 53152 GEAR CASE 1 15 01547 INSULATOR COLLAR 1
16
45298 45297
SHORT BLOCK ASSY - 49135/49430
SHORT BLOCK ASSY - 49455
1
16.1 02649 BEARING 1
16.2 01478 FRONT BEARING PLATE 1
16.3 50767 PIN 2
16.4 01479 SPACER 1
16.5 01480 VANE (4/PKG) 1
16.6
45292 45291
ROTOR - 49135/49430
ROTOR - 49455
1
16.7 01476 CYLINDER 1
16.8 02676 REAR BEARING PLATE 1
16.9 02696 BEARING 1
17 45269 GOVERNOR (BLUE) 1 18 45320 GOVERNOR CHAMBER 1 19 45305 HOUSING 1 20 96077 O-RING 1
21
09692 09709
SLEEVE - 49135 SLEEVE - 49430 SLEEVE - 49455
1
22 45315 BUSHING 1 23 97045 PIN 1 24 45263 THROTTLE LEVER 1 25 97060 PIN 1 26 45310 SEAL 1 27 58365 TIP VALVE 1 28 01468 SPRING 1 29 01564 AIR CONTROL RING 1 30 94520 MUFFLER ASSEMBLY 1
30.1 95711 SNAP RING 1
30.2 95438 O-RING 1
30.3 94521 MUFFLER BASE 1
30.4 94525 FELT SILENCER 1
30.5 94524 SINTERED MUFFLER 1
30.6 94522 MUFFLER CAP 1
30.7 95375 O-RING 1
30.8 94526 WASHER 1
30.9 94523 INLET ADAPTER 1
31 52755 VACUUM SHROUD - 49135 1 32 02341 TUBE CLAMP - 49135 1 33 97176 HOSE CLAMP - 49135 2 34 51791 VACUUM HOSE - 49135 1 35 51790 VACUUM ADAPTER - 49135 1 — 95987 WRENCH – 5/16" 1
Adhesive: A2= Loctite #271
A
8
= Loctite #567
A
10
= Loctite #243
A
17
= Loctite #454
Torque:N•m x 8.85 = In. - lbs.
Grease:G
1
= Lubriplate 630 AA
Oil:O
1
= Air Lube
O
A
T
G
KEY
Always follow adhesive manufacturers
cleaning and priming recommendations.
1.2
1.3
1.4
1.7
AR – “As Required”
G
1
G
1
G
1
G
1
A
8
34 N•m
T
34 N•m
T
0.8 N•m
T
1.8
1.4
1.9
1.12
1.11
2
28 N•m
T
28 N•m
T
11 N •m
T
17 N•m
T
3
4
1.5
5
1.6
G
1
G
1
G
1
G
1
A
2
O
1
A
2
G
1
6
7
8
9
7
6
7
9
10
11
8
12
A
2
17 N•m
T
28 N•m
T
13
7
8
9
G
1
A
8
A
8
4
5
14
15
7
16.1
16.2
16.4
16.5
16.3
16.6
16.7
16.8
16.9
A
10
17
18
19
20
21
A
8
A
8
2 N•m
T
22
23
24
25
26
27
28
29
O
1
A
8
28 N•m
T
30.1
30.2
30.3
30.4
30.5
30.6
30.7
30.8
30.9
49135/49430
49455
49135/49430
31
32
34
35
A
17
G
1
3
33
1.2 N• m
T
A
8
1.1
1.5
1.10
1.10
09708
Page 4
DYNABRADE, INC. www.dynabrade.com
8989 Sheridan Drive •Clarence, NY 14031-1419 •Phone: (716) 631-0100 •Fax: 716-631-2073 •International Fax: 716-631-2524
© DYNABRADE, INC., 2012 PRINTED IN USA PD12.19_Rev. 1_03/14
American National Standards Institute (ANSI)
1899 L Street, NW, 11th Floor • Washington, DC 20036 • Tel: 1 (202) 293-8020
Compressed Air & Gas Institute (CAGI)
1300 Sumner Ave. • Cleveland, OH 44115-2851 Tel: 1 (216) 241-7333 • Fax. (216) 241-0105
European Committee for Standardization (EN)
Rue de Stassart 36 • B - 1050 Brussels, Belgium
International Organization of Standards (ISO)
Case postale 56 • CH-1211 Geneva 20 Tel: + 41 22 749 01 11 • Fax: + 41 22 749 09 47
Government Printing Office (GPO)
Superintendent of Documents • Attn: New Orders P.O. Box 371954 • Pittsburgh, PA 15250-7954 Tel: 1 (202) 512-1803
MACHINE SPECIFICATIONS
REFERENCE CONTACT INFORMATION
LIFETIME WARRANTY
To validate Dynabrade Lifetime Warranty, you must register each tool at: www.dynabrade.com. Registration of each tool at website is required. Dynabrade will not honor Lifetime Warranty on unregistered tools. Please view the entire Lifetime Warranty Policy at : www.dynabrade.com.
Additional Specifications: Air Inlet Thread 1/4" NPT • Hose I.D. 1/4" (6 mm) Sound Level is the pressure measurement according to the method outlined in ISO regulation ISO-15744
Model Speed Power Sound Air Consumption Air Pressure Weight Length Height
49135 3,200 RPM .4 hp (298 W) 80 db(A) 26 SCFM (736 LPM) 90 PSIG (6.2 Bars) 2.3 lb. (1 kg) 12.4" (316 mm) 2.5" (64 mm)
49430 3,200 RPM .4 hp (298 W) 79 db(A) 26 SCFM (736 LPM) 90 PSIG (6.2 Bars) 1.8 lb. (.80 kg) 11.7" (296 mm) 1.2" (30 mm)
49455 950 RPM .4 hp (298 W) 77 db(A) 26 SCFM (736 LPM) 90 PSIG (6.2 Bars) 2.3 lb. (1 kg) 13" (329 mm) 1.2" (30 mm)
OPTIONAL ACCESSORIES
Motor Tune-Up Kit
Includes assorted parts to help maintain and repair motor.
Part No. 96541
Dynabrade Air Lube
Formulated for pneumatic equipment.
Absorbs up to 10% of its weight in water.
Prevents rust and formation of sludge.
Keeps pneumatic tools operating longer with greater power and less down time.
Part No. 95842: 1pt. (473 ml) Part No. 95843: 1 gal. (3.8 L)
Dynaswivel
®
Swivels 360° at two locations which allows an air hose to drop straight to the floor, no matter how the tool is held.
Part No. 94300 – 1/4" NPT.
Grease
Multi-purpose grease for all types of bearings, cams, gears.
High film strength; excellent resistance to water, steam, etc.
Workable range 0˚ F to 300˚ F
Part No. 95541: Push-Type Grease Gun Part No. 95542: 10 oz. (283.5 g) Tube.
Hex Key Wrench
12 mm hex
Use in housing core or air inlet.
Part No. 96399
Crowfoot Wrench
3/8" Drive
34 mm
Use on throttle body, housing core and lock nuts.
Part No. 96460
Overhose Assembly
Redirects exhaust away from operator.
Part No. 94995
For use with extended exhaust models only.
Lock Ring Tools Part No. 96165
For removal/tightening of 54550 Bearing Cap.
Part No. 97782
For removal/tightening of 53451 Adapter.
Loading...