The DXE-UT-8213LR has been designed to properly prepare coaxial cable for use with solder type PL-259 connectors. This unique cable
preparation tool will allow you to prepare RG-213 sized coaxial cable in the same proven manner as the K3LR world class contest station. This tool
is for standard solder type PL-259 connectors only and will work on a variety of RG-213 sized coaxial cable.
Properly cut the end of the coaxial cable with the DXE-CNL-911 Coax Cable Cutter to get a good flush cut. You want the coax to be round and not
oval when viewed from the end. If the cable is slightly oval, gently use pliers to round out the end of the coaxial cable. Place the prepared coaxial
cable end into the body of the DXE-UT-8213LR labeled "1st CUT". Firmly grip the coaxial cable and the DXE-UT-8213LR, turn the tool in a
clock wise direction while applying steady and slightly firm pressure. Grip the cable close to the tool. DXE-CG-8U Cable Grippers can help
maintain a good tight grip and keep the coax straight into the cutting tool. The DXE-UT-8213LR will begin cutting. Keep turning the tool until it
will not cut anymore, it will stop cutting at the proper length. Remove the coaxial cable, turn the DXE-UT-8213LR around for the second cut. Insert
the coaxial cable into the tool and again. Grip the cable close to the tool and turn the tool in a clock wise direction until the cutting is complete.
Remove the coaxial cable. Clean any excess cable cuttings from the tool. Fold the braid back and tin the center conductor with solder. Build up the
center insulation with 2-1/2 to 3 turns of 3M tape (part number TES-06132) so the PL-259 will not be loose. Fully insert the coax into the PL-259
and solder the center pin with solder. Twist the shield of the coax around the bottom of the PL-259. Use enough heat to add solder to the braid. Add
more heat and solder the braid to the base of the PL-259. Caution - the connector WILL get hot. When the PL-259 is warm to touch, wrap the base
of the PL-259 with 3M tape. Once the PL-259 is connected in your system - the complete connection must be properly weatherproofed to prevent
water from entering the PL-259 and coaxial cable. The premium cutting blades supplied with the DXE-UT-8213LR are made to last a long time. If
replacements are needed, order DXE-UT-RB-HD (customer supplied 7/64" Allen Wrench required).
1 - Cut Coaxial Cable. 2 - Insert in "1st Cut" side and turn 3. - Insert in other side for 2nd cut
Make sure it is round. clockwise to make first cut. turn clockwise to cut.
4. - Fold back the braided shield. 5. Use 2-1/2 to 3 turns of 3M tape to 6. Insert coax into the PL-259 and
Tin the center conductor with solder. build up the center insulation. Solder the Center Pin.
7. Twist the shield around 8. Add a small amount of solder 9. Using more heat, flow the solder
the base of the PL-259. to the braid. completely around the base of the PL-259.
10. While still warm (not hot) wrap the base
of the PL-259 with 3M tape.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Technical Support
If you have questions about this product, or if you experience difficulties during the installation, contact DX Engineering at (330) 572-3200. You can also e-mail us at:
Warranty
All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a perio d of one (1) year from date of shipment. DX Engineering’s sole obligation under these warranties s hall be to issue credit, repair or replace any
item or part thereof which is proved to be other than as warranted; no allowance shall be made for any labor charges of Buyer for replacement of parts, adjustment or repairs, or any other work, unless such charges are authorized in advance by DX Engineering. If DX
Engineering’s products are claimed to be defective i n material or workmanship, DX Engineering shall, upon prompt notice thereof, issue shipping instructions for return to DX Engineering (transportation-charges prepaid by Buyer). Every such claim for breach of these
warranties shall be deemed to be waived by Buyer unless made in writing. The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect, damaged by accident, rendered defective by reason of improper
installation, damaged from severe weather including floods, or abnormal environmental conditions such as prolonged exposure to corrosives or power surges, or by the performance of repairs or alterations outside of our plant, and shall not apply to any goods or parts
thereof furnished by Buyer or acquired from others at Buyer’s specifications. In addition, DX Engineering’s warranties do not extend to other equipment and parts manufactured by others except to the exte nt of the original manufacturer’s warranty to DX Engineering.
The obligations under the foregoing warranties are limited to the precise terms thereof. These warranties provide exclusive remedies, expressly in lieu of all other remedies including claims for special or consequential damages. SELLER NEITHER MAKES NOR
ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHER EXPRESS, STATUTORY, OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS, AND NO PERSON IS AUTHORIZED TO ASSUME FOR DX
ENGINEERING ANY OBLIGATION OR LIABILITY NOT STRICTLY IN ACCORDANCE WITH THE FOREGOING.
©DX Engineering 2017
DX Engineering®, DXE®, DX Engineering, Inc.®, Hot Rodz®, Maxi-Core®, DX Engineering THUNDERBOLT®, DX Engineering Yagi Mechanical®, EZ-BUILD®, TELREX®, Gorilla Grip® Stainless Steel Boom Clamps, Buttern ut®, SkyHawk™, SkyLark™,
SecureMount™, OMNI -TILT™, RF-PRO-1B®, AFHD-4® are trademarks of PDS Electronics, Inc. No license to use or reproduce any of these trademarks or other trademarks is given or implied. All other brands and product names are the trademarks of their
respective owners. Specifications subject to change without notice.
For best service, please take a few minutes to review this instruction sheet before you call.
1200 Southeast Ave. - Tallmadge, OH 44278 USA
Phone: (800) 777-0703 ∙ Tech Support and International: (330) 572-3200
Fax: (330) 572-3279 ∙ E-mail: DXEngineering@DXEngineering.com
DXEngineering@DXEngineering.com
Patent Pending