![](/html/ab/abdc/abdc94cea6b298b177a34f4bc851da9ded4af1658e527029a8af5baf465cecd8/bg1.png)
®
MODEL UFM
COMPACT ULTRASONIC FLOWMETERS
Cost Effective, Compact and Adjustable Design, Non-Invasive
E
O
D
I
V
O
N
L
I
N
[123.46]
Ø15/32
[Ø12.00]
FEMALE SMB
COAXIAL
CONNECTORS
1-7/64
[28.05]
2-7/16
[61.73]
4-5/32
[105.59]
29/64
[11.67]
[23.33]
2X 1/2
[12.75]
59/64
RED
BLACK
GREEN
WHITE
BLUE
BROWN
1-1/64
[25.70]
SHIELD
59/64
[23.50]
16.4´
[5 M]
3/4
4-7/64
[104.50]
45/64
[17.70]
59/64
[23.40]
31/32
[24.45
FLOW
The Model UFM Compact Ultrasonic Flowmeters are economical, clamp-on,
ultrasonic owmeter. The Model UFM implements the transit-time difference to
measure ow rates in pipes and can measure velocity and ow in pipes with outside
diameters ranging from 0.98 to 4.62˝ (24.89 to 117.35 mm). This model comes with a
volume pulse and 4-20 mA ow rate output.
FEATURES/BENEFITS
• Non-invasive pipe measurement
• Simple installation with all necessary components included such as converter,
sensor, cables and mounting accessories
• Compact and lightweight design, featuring an easily installed, all in one clamp-on
unit intended for homogeneous liquids that contain no air
• Screen offers easy to read text displaying both ow rate and total with a convenient
backlight for visual comfort
APPLICATIONS
• Flow measurement for heat metering
• Chilled water metering and monitoring
• Potable water metering and monitoring
• Process water metering and monitoring
KIT INCLUDES
• Converter with adjustable guiderail
• Set of 1.81 to 2.75˝ (46 to 70 mm) clamps
• Set of 2 to 5˝ (51 to 127 mm) clamps
• Set of small pipe adaptor circle clamps
• Set of small pipe adaptor V clamps
• Ultrasonic coupling grease
MODEL CHART
Model Description
UFM-1 Compact ultrasonic owmeter
SPECIFICATIONS
Service: Clean water with < 3% by
volume of particulate content.
Range: 0.33 to 32.8 ft/s (0.1 to 10 m/s).
Display: Backlit: 3.27˝ H x 0.74˝ W (83.1
mm x 18.8 mm), 2 line x 16 characters.
Accuracy: ±3% of ow reading for > 0.98
ft/s (> 0.3 m/s).
Power Requirements: 12-24 VDC or
VAC.
Power Consumption: 7 W max.
Temperature Limits: Process: 32 to
185°F (0 to 85°C); Ambient: 32 to 122°F
(0 to 50°C).
Outputs: Analog: 1 opto-isolated: 4
to 20 mA; Error current: 3.5 mA; Load
resistance: 620 Ω max; Pulse: 1 optoisolated MOSFET relay, 500 mA max,
166 pps max, 200 Hz max.
Enclosure Rating: IP54.
Enclosure Material: Plastic
polycarbonate.
Repeatability: ±0.5% of measured value.
Electrical Connections: 16.4´ (5 m)
cable.
Response Time: < 1 s.
Weight: 2.9 lb (1.315 kg).
Agency Approvals: CE.
ADDITIONAL SPECIFICATIONS
Applicable Pipe Material: Steel, copper,
or plastic.
Pipe Outside Diameter: 0.98 to 4.62˝
(24.89 to 117.35 mm).
Applicable Pipe Lining: None.
Pipe Wall Thickness: 0.02 to 0.39˝ (0.5
to 10 mm).
OPTIONS
Use order code: Description
NISTCAL-FU NIST traceable calibration certicate
USA: California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Flow Transmitters,
Ultrasonic