SERIES WE04 | 2-PIECE FLANGED STAINLESS STEEL BALL VALVE
®
FEATURES/BENEFITS
Eliminates threads and reduces installation and maintenance time
Vented ball to reduce operating torque
Full port design reduces the pressure drop across the value
Limit switches can be mounted to manual valves for remote monitoring
Weatherproof or explosion-proof electric actuators
Double acting or spring return anodized aluminum pneumatic actuators
APPLICATIONS
Gas or liquid ow control
Ideal for quick bubble tight shut-off
The SERIES WE04 incorporates a full port 2-piece anged SS ball valve for great ow rates with minimal pressure drop. The valve features a blowout proof stem for added safety, reinforced PTFE seats and seals for longer life, and a 316 SS (ASTM CF8M) ball for better performance. Actuators are direct mounted creating a compact assembly for tight spaces. Limit switches are able to be mounted directly to the valves allowing for remote position indication. The Series WE04 can be congured with either a pneumatic or electric actuator. Electric actuators are available in weatherproof or explosion-proof, a variety of supply voltages, and two-position or modulating control. Two-position actuators use the supply voltage to drive the valve open or closed, while the modulating actuator accepts a 4 to 20 mA input for valve positioning. Actuators feature thermal overload protection and permanently lubricated gear train. The pneumatic double acting actuator uses an air supply to drive the valve open and closed. The actuator has two supply ports, with one driving the valve open, and the other driving the valve closed. Spring return pneumatic actuators use the air supply to open the valve, and internally loaded springs return the valve to the closed position. Also available is the SN solenoid valve to electrically switch the air supply pressure between the air supply ports for opening and closing the valve. Actuators are constructed of anodized and epoxy coated aluminum for years of corrosion free service.
DWYER INSTRUMENTS, INC.
| |
®
VALVE SPECIFICATIONS
Service Compatible liquids and gases.
Body 2-piece.
Line Sizes 1/2 to 3˝.
End Connections 150# ANSI ange.
Pressure Limits 28˝ Hg to 275 psi (-0.7 to 19 bar) up to 392°F.
Wetted Materials Body and ball: 316 SS (CF8M); Stem: 316SS; Seat: RTFE/PTFE; Seal, washer and packing: PTFE.
Temperature Limits -20 to 392°F (-29 to 200°C).
Other Materials
O-ring: Fluoroelastomer; Handle: 304 SS; Washer: 301 SS; Stem nut, locking device, gland ring: 304 SS; Handle sleeve: PVC.
PNEUMATIC ACTUATOR (“DA” & “SR” SERIES) SPECIFICATIONS
Type DA series is double acting and SR series is spring return (rack and pinion).
Normal Supply Pressure DA: 40 to 115 psi (2.7 to 7.9 bar); SR: 80 psi (5.5 bar).
Maximum Supply Pressure 120 psi (8.6 bar).
Air Connections DA01: 1/8  female NPT; DA02 to DA05: 1/4  female NPT; SR02 to SR07: 1/4  female NPT.
Housing Material Anodized aluminum body and epoxy coated aluminum end caps.
Temperature Limits -40 to 176°F (-40 to 80°C).
Accessory Mounting NAMUR standard.
ELECTRIC ACTUATOR (“TD” & “MD” SERIES) SPECIFICATIONS
Power Requirements 110 VAC, 220 VAC, 24 VAC or 24 VDC (MD models not available in 24 VDC).
Power Consumption See instruction manual.
Cycle Time (per 90°) TD01: 4 s; MD01: 10 s; TD02 and MD02: 20 s; TD03 and MD03: 30 s.
Duty Rating 85%.
Enclosure Rating NEMA 4X (IP67).
Housing Material Powder coated aluminum.
Temperature Limits -22 to 140°F (-30 to 60°C).
Electrical Connection 1/2  female NPT.
Modulating Input 4 to 20 mA.
Standard Features Manual override, position indicator, and TD models come with two limit switches.
ELECTRIC ACTUATOR (“TI” & “MI” SERIES) SPECIFICATIONS
Power Requirements 110 VAC, 220 VAC, 24 VAC or 24 VDC.
Power Consumption See instruction manual.
Cycle Time (per 90°) See instruction manual.
Duty Rating See instruction manual.
Enclosure Rating NEMA 7, designed to meet hazardous locations: Class I, Group C & D; Class II, Group E, F & G; Division I & II.
Housing Material Powder coated aluminum.
Temperature Limits -40 to 140°F (-40 to 60°C).
Electrical Connection 1/2  female NPT.
Modulating Input 4 to 20 mA.
Standard Features Position indicator and two limit switches.