Dwyer Instruments SERIES TVA Catalog Page

A
B
D
H
.750
G
SERIES TVA
ALL FLUOROPOLYMER FLOWMETERS
75 mm and 125 mm, 10:1 Turndown, Back Connect, Corrosive Resistant
Flowmeters,
Variable Area & In-Line
F
E
C TYP.
I NPT (F)
TYP.
Model A B C D E F G TVA11XX
A
TVA13XX TVA22XX TVA24XX
Note: Panel mounting: Drill two holes: 3/4˝ dia. at 4.97˝ apart for 1/4˝ NPT
models, 7/8˝ dia. at 4.97˝ apart for 3/8˝ NPT models, 1˝ dia. at 8.72˝ apart for
B
1/2˝ NPT models, and 1-1/4˝ dia. at 8.47˝ apart for 3/4˝ NPT models (center-to­center).
4.97 [126]
4.97 [126]
8.72 [221]
8.47 [215]
0.56 [14]
0.56 [14]
0.88 [22]
1.00 [25]
1.06 [27]
1.25 [32]
1.75 [44]
1.75 [44]
3.35 [85]
4.65 [118]
4.57 [116]
5.95 [151]
1.25 [32]
1.50 [38]
2.00 [51]
2.25 [57]
6.16 [156]
6.16 [156]
10.4 [264]
10.4 [264]
1/4 3/8 1/2 3/4
The Series TVA All Fluoropolymer Flowmeters are ideal for high purity or corrosive
liquid applications. This series of owmeters features a 0 to 10 scale graduations denoting a discrete ow rate.
FEATURES/BENEFITS
• Chemically inert wetted components yield long life even in corrosive liquid applications
• Low installation costs with standard back process connections for easy panel mounting
APPLICATIONS
• Chemical injectors
• Deionized water systems
MODEL CHART Model Low Range
With Valve Without Valve Length Connections TVA1113
TVA1115 TVA1317 TVA1319
TVA1103 TVA1105 TVA1307 TVA1309
75 mm 75 mm 75 mm 75 mm
1/4˝ female NPT 1/4˝ female NPT 3/8˝ female NPT 3/8˝ female NPT
Flow Rate Water GPH (ml/min)
6.34 (400)
15.9 (1000)
39.6 (2500)
79.2 (5000)
SPECIFICATIONS
Service: Compatible liquids. Wetted Materials: Flowtube: PFA; Float
and end ttings: PTFE; Guide rods:
PCTFE.
Temperature Limit: 250°F (121°C). Pressure Limit: 100 psig (6.9 bar). Accuracy: ±5% FS @ 70°F (21.1°C)
and 14.7 psia (1 atm absolute).
MODEL CHART Model High Range
With Valve Without Valve Length Connections TVA22110
TVA24112 TVA24114
OPTIONS Use order code: Description NISTCAL-FL1 NIST traceable calibration certicate
TVA22010 TVA24012 TVA24014
125 mm 125 mm 125 mm
Repeatability: ±0.25%. Leak Integrity: 1 x 10–7 sccs of helium. Scales: Direct reading, 75 mm or 125
mm lengths.
Turn-down Ratio: 10:1. Mounting: Vertical.
1/2˝ female NPT 3/4˝ female NPT 3/4˝ female NPT
Flow Rate Water GPM (L/min)
3.43 (13)
7.93 (30)
11.9 (45)
DWYER INSTRUMENTS, INC. 254
Loading...