SERIES TTE
2X 1/2˝ FEMALE NPT OR M20
EXPLOSION-PROOF RTD TEMPERATURE TRANSMITTER
User Selectable Ranges, Optional LCD Display
[108.74]
TEMPERATURE
E
O
D
I
V
O
N
L
I
N
*Shown with optional
LCD display
4-9/32
3-29/32
[99.22]
4-15/32
[113.51]
2-23/32
[69.06]
10-23/64
[263.13]
1/2˝ MALE NPT
OR 1/2˝ MALE BSPT
[ø6.35]
TEMPERATURE
ø1/4
The Series TTE Explosion-Proof RTD Temperature Transmitter is the ideal product
for hazardous temperature measurement applications. The TTE series has seven preprogrammed temperature ranges that are selectable via an internal dip switch. For
those applications that need a custom range, the transmitter can be easily congured
for any range between -30 to 250°F with a minimum span of 40°F. The span and
zero can be quickly adjusted with a simple push-button design. This unit has optional
listings of FM for use in Class I, Division 1, Groups B, C and D, Class II, Division 1,
Groups E, F and G and Class III atmospheres or ATEX (Directive 2014/34/EU) for
2813 II 2 G Ex db IIC T6...T4 Gb (-20°C ≤ Ta ≤ + 70°C), 2813 II 1 D Ex ta
IIIC T111°C Da (-20°C ≤ Ta ≤ + 70°C) and IECEx for Ex db IIC T6...T4 Gb (-20°C ≤ Ta
≤ + 70°C), Ex ta IIIC T111°C Da (-20°C ≤ Ta ≤ + 70°C). The compact housing allows
for the transmitter to be mounted in virtually any application.
FEATURES/BENEFITS
• FM approved for Class I, Groups B, C, D; Class II, Groups E, F, G classied explosive
environments
• Optional LCD
• Output span selected from seven common ranges or user determined
APPLICATIONS
• Explosive process environments
• Offshore HVAC monitoring
MODEL CHART
Example TTE -1 04 -W -LCD TTE-104-W-LCD
Series TTE Explosion-proof RTD temperature transmitter
Agency 1
Probe
Length
Construction W Well probe
Options Blank
*Options that do not have ATEX and IECEx.
Attention: Units without the “2” sufx following “TTE” are not directive 2014/34/EU
(ATEX) Complaint. These units are not intended for use in potentially hazardous
atmospheres in the EU. These units may be CE marked for other directives of the
EU.
ACCESSORIES
Model Description
A-287 Mounting bracket for pipe or surface mounting
(Includes bracket and two 2˝ U-bolts)
2
02
04
06
09
12
15
18
FM*
ATEX/IECEx ameproof
2˝ probe
4˝ probe
6˝ probe
9˝ probe
12˝ probe
15˝ probe
18˝ probe
No LCD display
BSPT
1/2 male BSPT process connection
C5
C5-M housing paint specication
LCD
LCD display
M20
Female M20 thread electrical connection
SPECIFICATIONS
Temperature Sensor: Pt1000, 0.00385 DIN.
Output Temperature Ranges: User selectable – any range between -30 to 250°F
with a minimum span of 40°F.
Temperature Limits: Ambient: -4 to 158°F (-20 to 70°C); Process: -30 to 250°F
(-34.4 to 120°C).
Accuracy: Transmitter ±0.1% FS; Probe ±0.3% FS.
Thermal Drift Effects: ±0.02%/°C max.
Response Time: 250 ms.
Wetted Materials: 316 SS.
Process Connection: 1/2˝ male NPT or 1/2˝ male BSPT.
Conduit Connection: 1/2˝ female NPT or M20.
Probe Length: 2˝ to 18˝ (depending on model).
Pressure Limits: 2000 psi (137.9 bar).
Power Requirements: 10-35 VDC.
Output Signal: 4-20 mA (2- wire loop powered).
Optional Display: 2 lines X 8 character LCD.
Enclosure Rating: Weatherproof and Explosion-proof. Listed with FM for Class
I, Division 1, Groups B, C and D, and dust-ignitionproof for Class II, Division 1,
Groups E, F and G and Class III atmospheres.
ATEX Certied:
ta IIIC T111°C Da, T6 Process Temp ≤80°C, Temperature Class T5 Process Temp
≤95°C, Temperature Class T4 Process Temp ≤120°C as dened on nameplate. EUtype Cericate No.: EMT17ATEX0021 X.
ATEX Standards: EN 60079-0:2012+A11:2013; EN 60079-1:2015; EN 60079-
31:2014.
IECEx Certied: For Ex db IIC T6...T4 Gb, Ex ta IIIC T111°C Da, T6 Process Temp
≤80°C, Temperature Class T5 Process Temp ≤95°C, Temperature Class T4 Process
Temp ≤120°C as dened on nameplate.
IECEx Certicate of Conformity: Element IECEx EMT 17.0007X; IECEx
Standards: IEC 60079-0:2011 (Edition 6); IEC 60079-1:2014 (Edition 7);
IEC 60079-31:2013 (Edition 2).
Weight: 2 lb 8 oz (1134 g).
Agency Approvals: FM, CE, ATEX/IECEx.
THERMOWELLS - MACHINEDu
Model Material Length
TE-TNS-N044N-12
TE-TNS-N064N-12
TE-TNS-N094N-12
TE-TNS-N124N-12
FIELD-SELECTABLE RANGES
40 to 90°F (4.4 to 32.2°C)
-20 to 140°F (-28.9 to 60°C)
0 to 100°F (-17.8 to 37.8°C)
30 to 240°F (-1.1 to 115.6°C)
32 to 212°F (0 to 100°C)
32 to 122°F (0 to 50°C)
-30 to 65°C (-1.1 to 18.3°C)
Custom range between -30 to 250°F (-34.4 to 121.1°C)
uTechnical Specications and Additional Thermowell Models: See page 145 (Series TE-TNS)
2813 II 2 G Ex db IIC T6...T4 Gb, 2813 II 1 D Ex
Connection
304 SS
304 SS
304 SS
304 SS
Machined thermowell
(Internal/External) (NPT)
4˝
1/2˝ / 3/4˝
6˝
1/2˝ / 3/4˝
9˝
1/2˝ / 3/4˝
12˝
1/2˝ / 3/4˝
DWYER INSTRUMENTS, INC.
Temperature Transmitters
133