Dwyer Instruments SERIES SSV-B Catalog Page

SERIES SSV-B | W.E. ANDERSON™ BY DWYER
L
W
BRASS SOLENOID VALVE, 2-WAY GUIDED NO
Compact Design, Immune to Mounting Orientation
VALVES
offers a wide range of valve sizes and ow ranges with connection sizes from 1/8˝ to 2˝ NPT and orices from 3 mm to 50 mm.
FEATURES/BENEFITS
Can be oriented in any position
• Compact design
• Field replaceable coils
MODEL CHART Model Connection, NPT Orice in [mm] Cv Value Voltage SSV-B1N1
SSV-B2N1 SSV-B3N1 SSV-B4N1 SSV-B5N1 SSV-B6N1 SSV-B7N1 SSV-B8N1 SSV-B9N1
Note: Consult factory for 220 VAC, 24 VAC and 24 VDC.
1/8˝ 1/4˝ 3/8˝ 1/2˝ 3/4˝ 1˝ 1-1/4˝ 1-1/2˝ 2˝
APPLICATIONS
Wide variety of applications, suitable air,
gas, water and other liquids
0.12 [3]
0.12 [3]
0.51 [13]
0.51 [13]
0.79 [20]
0.98 [25]
1.38 [35]
1.57 [40]
1.97 [50]
0.25
0.25
4.5
4.5
7.6 12 22
30 48
110 VAC 110 VAC 110 VAC 110 VAC 110 VAC 110 VAC 110 VAC 110 VAC 110 VAC
DC (W)Inrush Holding Inrush Holding
-
-
32
W in [mm]
1-9/64 [29] 1-9/64 [29] 1-57/64 [48] 1-57/64 [48] 2-9/32 [58] 2-3/4 [70] 3-25/32 [96] 3-25/32 [96] 4-47/64 [120]
ModelLin [mm]Hin [mm] SSV-B1NX
H
SPECIFICATIONS Service: Compatible gases and liquids.
Line Size: 1/8 to 2˝ NPT. End Connections: Female NPT. Operating Pressure: 1/8 to 1/4˝: 0 psi
(0 bar) to 87 psi (6 bar); 3/8 to 2˝: 7.3 psi (0.5 bar) to 116 psi (8 bar).
Pressure Limit: 174 psi (12 bar). Wetted Material: Body: Brass; Spring:
304 SS; Seal: NBR. Temperature Limits: Process: 176°F (80°C); Ambient: 32 to 149°F (0 to 65°C).
Voltage
220 VAC 110 VAC
24 VDC
USA: California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
SSV-B2NX SSV-B3NX SSV-B4NX SSV-B5NX SSV-B6NX SSV-B7NX SSV-B8NX SSV-B9NX
50 Hz (VA) 60 Hz (VA)
82 82
-
33 33
-
1-5/8 [41] 1-5/8 [41] 2-19/32 [66] 2-19/32 [66] 2-61/64 [75] 3-25/32 [96] 5-5/32 [131] 5-5/32 [131] 6-1/2 [165]
82 82
-
3-15/32 [88] 3-17/64 [83] 4-57/64 [124] 4-57/64 [124] 5-1/8 [130] 5-5/8 [143] 6-7/32 [158] 6-7/32 [158] 7-3/64 [179]
Power Requirements: Standard: 110 VAC; Optional: 220 VAC, 24 VDC consult
factory.u
Power Consumption: See table. Enclosure Rating: NEMA 13 (IP54). Electrical Connection: DIN connection. Other Materials: Nylon. Mounting Orientation: Any position,
best if solenoid vertically above valve.
Weight: See table. Type of Operation: NO. Agency Approvals: CE.
28 28
-
uSolenoid Coils: See page 424 (Series SRC)
Weight lb [kg]
0.88 [0.40]
0.86 [0.39]
1.98 [0.90]
1.98 [0.90]
2.42 [1.10]
3.52 [1.60]
6.60 [3.00]
6.16 [2.80]
5.00 [11.0]
Loading...