Dwyer Instruments SERIES SC4 Catalog Page

0.886 [22.5]
2.950 [75]
3.880 [98.5]
1.400 [35.5]
Series
SC4
Iso Verter®II Signal Conditioning Modules
Accepts Virtually All Standard Process Signals
PROCESS CONTROL
Isolating Transmitters
Signal Conditioners/
Linearized and isolated RTD and Thermocouple transmitters are part of the Series
SC4000 Iso Verter input from the output and from ground. Compatible with industry standard 35 mm DIN Rail mount transmitters and isolators, these modules are easily applied in new or existing installations.
The SC4380 Process Signal Converter/Isolator accepts virtually all standard process signals as an input, and isolates and retransmits the signal in either the same units or virtually any other standard process signal. The SC4380 can be field programmed for reverse or direct action and can receive and transmit single sided or bipolar* signals. Low Voltage units (SCL) are also available.
The SC4151 RTD Transmitters each offer a f ixed scale range input (selected when ordered) and a linearized, isolated, field selectable 4 to 20 mA or 0 to 10 VDC output. Output is selected by simple switch settings. Low Voltage units (SCL) are also available.
The SC4130 Thermocouple Transmitter offers a fixed scale range input (selected when ordered) and a linearized, isolated, field selectable 4 to 20 mA or 0 to 10 VDC output. Output is selected by simple switch settings. Low Voltage units (SCL) are also available.
Note: The term “bipolar” refers to an input or output that crosses zero volts. Certain devices have ranges that run from minus to plus voltages (eg. -1 to +5 VDC, -10 to +10 VDC, etc.). The SC4380 Iso Verter input or provide a bipolar output.
ACCESSORY A-360,
Aluminum DIN Rail 1 m
®
II Signal Conditioning Modules. These modules completely isolate the
®
II can be set up to accept a bipolar signal
SPECIFICATIONS Isolation: 1500 VAC RMS. Linearity: 0.1% of full-scale. Drift: ±0.02%/°C typical, ±0.05%/ °C maximum. Power Supply: SC: 85 to 265 VDC/VAC 50 to 400 Hz; SCL: 12 to 24 VDC/VAC 50
to 400 Hz.
Output Loads: Current: 600 Ω max voltage: 500 Ω min (20 mA maximum). Input Characteristics: SC4380: Voltage: 1 M Ω impedance; Current: 10 Ω;
SC4151: RTD Search current < 500 µA; SC4130: 3 M Ω impedance.
Case Size: 0.866˝ W (22.5 mm) x 2.950˝ H (75.0 mm) 3 3.880˝ D (98.5 mm). Mounting: Mounts on industry standard 35 mm DIN Rail (DIN EN50022-35).
To Order Use Range Code as Suffix: SC4130 & SCL4130
Model SC4130 Range Codes
A = J, -100 to 200°C C = J, 0 to 100°C D = J, 0 to 500°F E = J, 0 to 250°C F = J, 0 to 750°C G = J, 0 to 1000°F H = K, -150 to 350°F J = K, -100 to 200°C K = K, 0 to 500°F L = K, 0 to 250°C M = K, 0 to 1000°F N = K, 0 to 500°C P = K, 0 to 2000°F R = K, 0 to 1000°C S = T, -300 to 250°F T = T, -200 to 200°C
SC4151 & SCL4151
Model SC4151 Range Codes
A = DIN, -100 to 200°C B = DIN, 0 to 100°C C = DIN, 0 to 150°C D = DIN, 0 to 200°F E = DIN, 0 to 200°C F = DIN, 0 to 400°F G = DIN, 0 to 250°C H = DIN, 0 to 500°F J = DIN, 0 to 500°C K = DIN, 0 to 1000°F
SC4380 & SCL4380 Operating Ranges
Inputs Outputs
Current
0 to 5 mA 0 to 10 mA 0 to 10 mA 0 to 20 mA 0 to 50 mA 0 to 100 mA 1 to 5 mA 4 to 20 mA 10 to 50 mA
Voltage
0 to 100 mV 0 to 200 mV 0 to 500 mV 0 to 1 V 0 to 5 V 0 to 10 V 1 to 5 V 2 to 10 V
Model SCL4130 Range Codes
A = J, -100 to 200°C C = J, 0 to 100°C D = J, 0 to 500°F E = J, 0 to 250°C F = J, 0 to 750°C G = J, 0 to 1000°F H = K, -150 to 350°F J = K, -100 to 200°C K = K, 0 to 500°F L = K, 0 to 250°C M = K, 0 to 1000°F N = K, 0 to 500°C P = K, 0 to 2000°F R = K, 0 to 1000°C S = T, -300 to 250°F T = T, -200 to 200°C
Model SCL4151 Range Codes
A = DIN, -100 to 200°C B = DIN, 0 to 100°C C = DIN, 0 to 150°C D = DIN, 0 to 200°F E = DIN, 0 to 200°C F = DIN, 0 to 400°F G = DIN, 0 to 250°C H = DIN, 0 to 500°F J = DIN, 0 to 500°C K = DIN, 0 to 1000°F
Current
0 to 1 mA 0 to 5 mA 0 to 20 mA 1 to 5 mA 4 to 20 mA
Voltage
0 to 1 V 0 to 5 V 0 to 10 V 1 to 5 V 2 to 10 V
355