Dwyer Instruments SERIES SBLT2, SERIES SBLTX Data Sheet

SERIES SBLT2 & SBLTX | MERCOID SUBMERSIBLE LEVEL TRANSMITTERS
®
SBLT2 SBLTX
(ATEX option available)
NOW WITH 72 HOUR
OUT OF STOCK LEAD TIME!
FEATURES/BENEFITS
Slim design for tight applications with bullet nose, which protects the diaphragm from damage
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power
supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on SBLT2 models
Maintenance free lter eliminates particulate or water droplets from entering and damaging the transducer
UL approved intrinsically safe on SBLTX models for use in hazardous locations when used with proper barrier
Excellent chemical compatibility for wide application use
NPT connection allows the unit to be rigidly installed in a pipe/conduit, or the addition of a A-625 hanging loop for attaching a
chain for pulling out of the installation
Standard 72 hour lead time ensures minimal downtime
DESCRIPTIONAPPLICATIONS
Air economizers
Outdoor temperature and relative humidity reference for building systems
Well monitoring
Ground water monitoring
Environmental remediation
Surface water monitoring
Down hole
Water tanks
The Series SBLT2 & SBLTX Submersible Level Transmitters are manufactured for years of trouble free service. These series measure the height of liquid above the position in the tank referenced to atmospheric pressure. The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing.
SPECIFICATIONS
Service Compatible liquids.
Wetted Materials Body: 316 SS, 316 L SS; Bullet nose: PVC; Cable: Polyether polyurethane or ETFE; Seals: Fluoroelastomer.
Accuracy ±0.25% FS*.
Temperature Limit SBLT2: Polyurethane: 0 to 150°F (-18 to 66°C); ETFE: 0 to 200°F (-18 to 93°C); SBLTX: ETFE: -4 to 176°F (-20
to 80°C); Polyurethane: -4 to 149°F (-20 to 65°C).
Compensated Temperature Range SBLT2: 0 to 140°F (-18 to 60°C); SBLTX: 0 to 176°F (-18 to 80°C).
Thermal Effect ±0.02% FS/°F. Pressure Limit 2X FS.
Power Requirement SBLT2: 10-30 VDC; SBLTX: 10-28 VDC.
Output Signal 4-20 mA DC, 2-wire.
Response Time 50 ms.
Max. Loop Resistance 900 Ω at 30 VDC.
Electrical Connection Wire pigtail.
Mounting Orientation Suspended in tank below level being measured.
Electrical Protection SBLT2: Lightning and surge protection; SBLTX: None.
Weight 2.2 lb (1.0 kg).
Agency Approvals SBLT2: CE; SBLTX: CE, cULus intrinsically safe for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E,
*Congured ranges below 5 psi (11.54 ft w.c.) (3.52 m w.c.) ±1% FS accuracy.
**Up to 196 ft (59.5 m) for ETFE cable; Up to 333 ft (101.5 m) for polyurethane cable.
F, G; Class III Div. 1; ATEX: II 1 G Ex ia IIC T4 Ga and II 1 D Ex ia IIIC T135C Da (according to control drawing 001833-43)**.
DIMENSIONS
BREATHER TUBE
7-3/16 [182.75]
1/2 NPT SUBMERSIBLE
Ø1 [Ø25.40]
SBLT2/SBLTX
HOW TO ORDER
Use the bold characters from the chart below to construct a product code.
SBLT2 -5 -40 -ETFE -P1
SERIES
SBLT2: Submersible level transmitter SBLTX: Submersible level transmitter (intrinsically safe)
*RANGE psi (ft w.c.) [m w.c.]
-5: 5 (11.54) [3.52]
-10: 10 (23.09) [7.04]
-15: 15 (34.63) [10.56]
-20: 20 (46.18) [14.08]
-3.5M: 4.97 (11.48) [3.5]
-5M: 7.11 (16.40) [5]
-10M: 14.21 (32.81) [10]
*Additional pressure ranges available, consult factory
CABLE
OPTIONS
-P1: 1/4˝ NPT male
-P2: 1/4˝ NPT female
-P3: 1/4˝ BSPT male ISO 228 R
-P4: 1/4˝ BSPT female ISO 228 RC
-P11: 3/4˝ clean-out type
-ATEX: ATEX intrinsically safe
CABLE TYPE
BLANK: Polyurethane
-ETFE: ETFE
**CABLE LENGTH ft (m)
-40: 40 (12.2)
-60: 60 (18.3)
-5M: 16.40 (5)
-10M: 32.81 (10)
-18M: 59.06 (18)
**Congured cable lengths available
ACCESSORIES
Model Description MTL5041 MTL7706 A-297 A-625
O
Intrinsically safe galvanic isolator Intrinsically safe zener barrier
Dessicant lter for vent tube. Removes humidity for protection of the sensor. Changes color to show saturation
316 SS cable hanger for attaching chain for easy pulling out of application
from 10 to 2000 ft (3 to 610 m)
DWYER INSTRUMENTS, INC.
©Copyright 2020 Dwyer Instruments, Inc. Printed in U.S.A. 12/20 DS-SBLT2 Rev. 7
Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identied in this publication without notice. Dwyer advises its customers to obtain the
latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current.