Dwyer Instruments SERIES RTI2 Catalog Page

®
4-21/64 [110]
[104.10]
4-49/64 [121.20]
SERIES RTI2
RATE/TOTAL INDICATOR
FLOW
Loop Powered, Converts Pulse Frequency to 4 to 20 mA, High/Low Flow Alarm
4-23/64 [110.50]
2-1/2
[63.50]
[104.10]
The SERIES RTI2 Rate & Total Indicator is an indicator/transmitter that takes the pulse
output signal from compatible owmeters, displays ow rate and total, and provides
output signals. It is compatible with the Series EFS2, IEFS, PDWS, and FLMG.
FEATURES/BENEFITS
• Can be mounted on a wall or mounted on the owmeter for added exibility
• Accessory mounting kits make it easy to change the mounting orientation
• High environmental protection with semi-exible urethane potted electrical
components
• Provides a pulse, 4 to 20 mA and dual-relay output
APPLICATIONS
• Water treatment
• Water utilities
• Industrial chemical handling
MODEL CHART Model Description RTI2-W
Wall-mounted
RTI2-M
Meter-mounted
RTI2-P
Panel-mounted
ACCESSORIES Model Description MMK2
Meter mounting kit
WMK2
Wall mounting kit
SPECIFICATIONS Input: 5 V pulse or contact closure; 1 to 15 pulses/s.
Temperature Limits: Process: -32 to 131°F (0 to 55°C); Storage: -40 to 158°F (-40
to 75°C). Output: Current sinking square wave pulse: Scaled pulse output (0.1 s duration 6.1 Hz max. or high alarm output or low alarm output), sensor pass-through pulse output (un-scaled); Pulse output range: 0.1 to 9999999.9 units/pulse; Analog: 4 to 20 mA, 24 to 30 VDC.
Power Requirements: 7 to 30 VDC @ 4 mA (4 to 20 mA when loop-powered). Display: Rate: 8 digits, 1/2  H LCD; Total: 8 digits, 5/16  character height. K-Factor Range: 0.001 to 999999.999. Flow Alarm Output Range: 0.1 to 99999.99. Enclosure Material Housing: Die-cast powder-coated aluminum; Faceplate
#HP92W Lexan.
Enclosure Rating: NEMA 4X (IP67). Electrical Connection: Terminal blocks, #22 AWG, 3 conductor 18  (5.5 m) cable
(2000  max.).
Mounting: See model chart. Weight: 3 lb (1361 g).
3-3/8
[85.60]
Loading...