SERIES RM
RATE-MASTER® POLYCARBONATE FLOWMETERS
FLOW
2˝, 5˝ or 10˝ Scale, Interchangeable Bodies
F
BACK
WIDTH
Flowmeters,
V
Variable Area & In-Line
A
C
B
K
E
D
G
I
FULL OPEN
L
DIMENSIONS - FLOWMETER
Model RMA Model RMB Model RMC
A
4-9/16 [115.90]
B
3 [76.20]
1/8 NPT conn.
C
1-5/8 [41.28]
10-32 mtg. holes
D
3/8 [9.525]
E
1-1/16 [26.99]
F
1-3/16 [30.16]
G
11/16 [17.46]
H
E
O
D
I
O
N
L
I
N
Model RMC
10˝ scale, 15-3/8˝ high
Model RMB-SSV
5˝ scale, 8-3/4˝ high
Model RMA-TMV
2˝ scale, 4-13/16˝ high
61/64 [24.21]
I
1-3/8 [34.92]
J
3/4 [19.05)
K
4-13/16 [122.20]
L
1 [25.40]
8-1/2 [215.90]
6-7/16 [163.50]
1/4 NPT conn.
3-15/16 [100.00]
1/4-20 mtg. holes
5/8 [15.88]
1-7/8 [47.63]
1-3/4 [44.45]
1 [25.40]
1-7/16 [36.51]
1-13/16 [46.04]
1-1/4 [31.75]
8-3/4 [222.30]
1-1/2 [38.10]
15-1/8 [384.20]
12-1/4 [311.20]
1/2 NPT conn.
8-3/4 [222.30]
3/8-24 mtg. holes
1 [25.40]
2-3/4 [69.85]
2-1/2 [63.50]
1-7/16 [36.51]
1-31/32 [50.00]
2-1/2 [63.50]
2 [50.80]
15-3/8 [390.50]
2-1/4 [57.15]
The Series RM Rate-Master® Polycarbonate Flowmeters are a line of general use,
direct reading precision owmeters suitable for both gas and liquid applications. This
Series consists of 2˝ (51 mm), 5˝ (127 mm) and 10˝ (254 mm) scales that can be panel
or surface mounted with optional precision metering valves. Within a given Series, the
Rate-Master
®
owmeter bodies can be instantly interchanged, allowing the piping to
remain undisturbed, interchangeability of the ranges, and easy cleaning.
FEATURES/BENEFITS
• Direct reading scales eliminate the need for troublesome conversions
• Stainless steel backbone absorbs piping torque reducing installation damage and
cost
• Shatter-proof polycarbonate allows for long operation life
• Precision injection molding around a precision tapered pin enables high repeatability
• Increased reading accuracy with special integral ow guides that stabilize oat
movement
• Scale graduations on both side of the indicating tube allow for instantaneous ow
reading saving time
APPLICATIONS
• Medical equipment
• Air samplers
• Gas analyzers
• Pollution monitors
• Chemical injectors
• Cabinet purging
DWYER INSTRUMENTS, INC. | 246
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Body: Polycarbonate; O-ring: Neoprene and Buna-N; Metal
parts: SS (except for optional brass valve); Float: SS, black glass, aluminum, K
monel, tungsten carbide depending on range.
Temperature Limit: 130°F (54°C).
Pressure Limit: 100 psi (6.9 bar).
Accuracy: RMA: 4%; RMB: 3%; RMC: 2% of FS.
Process Connection: RMA: 1/8˝; RMB: 1/4˝; RMC: 1/2˝ female NPT.
Weight: RMA: 4 oz (113.4 g); RMB: 13 oz (368.5 g); RMC: 39 oz (1105.6 g).
Agency Approvals: Meets the technical requirements of EU Directive 2011/65/EU
(RoHS II).
CAUTION: Dwyer
®
Rate-Master® owmeters are designed to provide satisfactory
long term service when used with air, water, or other compatible media. Refer to
factory for information on questionable gases or liquids. Caustic solutions, anti-freeze
(ethylene glycol) and aromatic solvents should denitely not be used.
®
SERIES RM
RATE-MASTER® POLYCARBONATE FLOWMETERS
Gas Flow from 0.05 to 1800 SCFH, Water Flow to 10 GPM
FLOW
RANGE CHART - RMA 2˝ SCALE - POPULAR RANGES
Range No. SCFH Air Range No. LPM Air
1
2
3
4
5
6
7
8
9
10
Range No. CC/Min. Air Range No. GPH Water
151*
150*
11
12
13
14
*Accuracy ±8%
RANGE CHART - RMB 5˝ SCALE - POPULAR RANGES
Range No. SCFH Air Range No. SCFH & LPM Air
49*
50
51
52
53
54
55
56
57
Range No. GPH Water
82
83
84
85
*Accuracy ±5%
.05 to .4
.1 to 1
.2 to 2
.5 to 5
1 to 10
2 to 20
5 to 50
10 to 100
15 to 150
20 to 200
5 to 50
10 to 100
30 to 200
50 to 500
100 to 1000
200 to 2500
0.5 to 5
1 to 10
3 to 20
4 to 50
10 to 100
20 to 200
40 to 400
50 to 500
60 to 600
1 to 12
1 to 20
4 to 40
10 to 100
26
21
22
23
24
25
Range No. CC/Min. Water
32
33
34
42
43
44
45
50D
51D
52D
53D
54D
Range No. GPH & LPM Water
82D
83D
85D
.5 to 5
1 to 10
2 to 25
5 to 50
5 to 70
10 to 100
5 to 50
10 to 110
20 to 300
1 to 11
2 to 24
4 to 34
5 to 50
1.2 to 10/0.6 to 5
2 to 20/1 to 9.5
4 to 50/2 to 23
10 to 100/5 to 50
20 to 200/10 to 95
1 to 12/0.06 to 0.76
1 to 20/0.065 to 1.25
10 to 100/0.8 to 6.2
MODEL CHART
Model Description
RMA-X
RMA-X-BV+
RMA-X-SSV+
RMA-X-TMV*+
RMB-X
RMB-X-BV+
RMB-X-SSV+
RMC-X
RMC-X-BV+
RMC-X-SSV+
How To Order: Series-Range No.(“X”)-Valve-Option
Example: RMA-2-SSV
(Series RMA with .1-1 SCFH air range & stainless steel valve)
*Provide same precision construction but for vacuum applications.
+Valve is designed for ow adjustment only, not intended to be
used as an open/shut-off valve.
OPTIONS
To order add sufx: Description
-NIST
-APF
-BPF
-CPF
Note: Special ranges, scales, mounting arrangements, etc., are
available on special order, or in OEM quantities.
Standard RMA
RMA with brass valve
RMA with stainless steel valve
RMA with top mounted valve
Standard RMB
RMB with brass valve
RMB with stainless steel valve
Standard RMC
RMC with brass valve
RMC with stainless steel valve
NIST traceable calibration certicate
Adjustable pointer ag for Series RMA
Adjustable pointer ag for Series RMB
Adjustable pointer ag for Series RMC
Adjustable pointer ags
Red lined pointer ags provide quick visual reference to a
required ow level. Of clear plastic, they snap into place inside
bezel and slide to desired level.
Variable Area & In-Line
Flowmeters,
RANGE CHART - RMC 10˝ SCALE - POPULAR RANGES
Range No. SCFH Air Range No. GPH Water
101
102
103
104
105
106
107
108
Range No. SCFM Air
121
122
123
5 to 50
10 to 100
20 to 200
40 to 400
60 to 600
100 to 1000
120 to 1200
200 to 1800
1 to 10
2 to 20
4 to 30
134
135
Range No. GPM Water
141
142
143
144
145
2 to 20
8 to 90
.1 to 1
.2 to 2.2
.4 to 4
.8 to 7
1.2 to 10
ACCESSORIES
Model Description
RKA
RK-RMB
Regulator kit for Series RMA
Regulator kit for Series RMB
Regulator kits
Available as optional extras for both Rate-Master® Flowmeters
and Visi-Float
VFA Visi-Float
differential pressure regulator. Recommended for use where
inlet air pressure uctuates widely and constant ow is required.
The regulator maintains a constant pressure differential of
approximately 3 ±.15 psig. Supply pressure must be at least 3
psig above the owmeter discharge to operate. The standard
regulator may be used with any Dwyer Series RM or VF owmeter
up to 200 scfh. For higher ow rates consult the factory.
USA: California Proposition 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
®
Flowmeters models. This view shows Model
®
owmeter with integrally connected constant
DWYER INSTRUMENTS, INC. |
247