Dwyer Instruments SERIES DCS, SERIES RDCS Catalog Page

Series
DCS/RDCS
Springless Diaphragm Valves
Pulse Valve, Ideal for Dust Collection Systems and Bag Houses
DCS35T1D
DCS35C1D
The Series DCS/RDCS Springless Dust Collection Valves are ideal for use with
the Series DCT1000 and Series DCT500 duct collection timer boards. A springless design offers not only durability, but also reliability for an exceptional cleaning pulse. Both the Serie s DCS and RDCS have the option for either coupling or NPT connections. The coupling connection allows for a quick and simple installation. Only the stub pipe and blowtube need to be cleaned and deburred before the valve is fit into position. The “T” Series DCS has fema le threaded connections and the “C” Series DCS has a coupling connection. Both the “ T” and “C” versions have a 90° angle between the inlet and outlet: the most suitable configuration for pulse valve applications. The valves are offered in both integrated and remote coil configurations.
VALVES
EATURES
Thermoplastic polyurethane diaphragm for longer life High flow factor for effective cleaning Unique diaphragm design eliminates spring Valve can be mounted in any position Quick on & off response time
ACCESSORIES A-237, Muffler BDA-5030-Q, 3/4˝ DCS/RDCS Pulse Valve Replacement Diaphragm BDA-5230-Q, 1˝ DCS/RDCS Pulse Valve Replacement Diaphragm BDA-5430-Q, 1-1/2˝ DCS/RDCS Pulse Valve Replacement Diaphragm RSV1D-COIL, 110 VAC DIN Replacement Solenoid Coil RSV2D-COIL, 220 VAC DIN Replacement Solenoid Coil
Valves,
RSV3D-COIL, 24 VAC DIN Replacement Solenoid Coil
Diaphragm Pulse
Cv
Model RDCS20T RDCS20C DCS20T1D DCS20C1D RDCS25T RDCS25C DCS25T1D DCS25C1D RDCS35T RDCS35C DCS35T1D DCS35C1D
*110 VAC with DIN Connector
Series DCS/RDCS Model Guide Construction
Size
Connection
Voltage
Size
3/4˝ 3/4˝ 3/4˝ 3/4˝ 1˝ 1˝ 1˝ 1˝ 1-1/2˝ 1-1/2˝ 1-1/2˝ 1-1/2˝
DCS RDCS
Solenoid
Remote Remote Integral* Integral* Remote Remote Integral* Integral* Remote Remote Integral* Integral*
20 25 35
T C
1D 2D 3D
Connection
NPT Coupling NPT Coupling NPT Coupling NPT Coupling NPT Coupling NPT Coupling
Integrated coil Remote coil 3/4˝ 1˝ 1-1/2˝ NPT Coupling 110 VAC DIN (for integrated coil only) 220 VAC DIN (for integrated coil only) 24 VDC DIN (for integrated coil only)
Number of Diaphragms
1 1 1 1 1 1 1 1 1 1 1 1
Factor (gal/min)
14 14 14 14 23 23 23 23 42 42 42 42
RDCS20C
RDCS35T
SPECIFICATIONS Service: Compatible gases, filtered and oil free. Wetted Materials:
Body: Aluminum; Diaphragm disc: Thermoplastic polyurethane; Solenoid seals: NBR.
Other Materials:
Cover: Aluminum; Body bolts: Zinc plated SS; Solenoid: Nylon.
Pressure Limits: Min. of 4.4 psi (0.3 bar), max. of 124.7 psi (8.6 bar). Temperature Limits:
Ambient: -4 to 140°F (-20 to 60°C); Operating: -4 to 185°F (-20 to 85°C).
Power Requirements: 110 VAC, 220 VAC, or 24 VDC for DCS models. Power Consumption: 12 W; Inrush: 17 VA; Holding: 14.5 VA for DCS models. Electrical Connection: DIN connection for DCS models. Enclosure Rating: NEMA 4X (IP65) for DCS models. Process Connection: See model chart. Mounting Orientation: Any position. Agency Approval: CE.
DIAPHRAGM VALVE CONSTRUCTION
NEMA 4X (IP65)
Solenoid Coil
Solenoid
Cover
Unique Diaphragm
Design Eliminates
Need for a
Spring
Diaphragm
Body
RDCS35C
Integrated Solenoid Stem
Robust Die Cast Aluminum Body
502
DWYER INSTRUMENTS, INC.
AIR INLET
DIAPHRAGM
FLOW
OUTLET
EXHAUST
B
E
D
A
B
E
D
A
F
F
C
C
Series
DCS/RDCS
Springless Diaphragm Valves
Dimensional Chart
VALVES
DCS Dimensional Chart
Connection
NPT
Coupling
RDCS Dimensional Chart
Connection
NPT
Coupling
Operating Principle
The valve is divided into two chambers by a diaphragm. These upper and lower chambers are connected by a small air passage so both chambers see the same pressure. When the exhaust is closed air cannot vent out of the upper chamber and the valve stays closed as shown in Figure 1. When the exhaust on the upper chamber is opened the air pressure decreases on top of the diaphragm allowing the air pressure on the bottom to force open the valve by pushing the diaphragm up as shown in Figure 2. When the valve opens an abrupt air blast comes through the valve outlet and is directed by the dust collector to the dirty filter. The air pulse then blows out through the filter from the inside blowing the particulate accumulation off of the filter to clean it. After the air pulse the pressure in the upper and lower chamber will equalize and the diaphragm will return to the closed position. The valve exhaust port is controlled by either an integral or remote solenoid.
Model DCS20TxD DCS25TxD DCS35TxD DCS20CxD DCS25CxD DCS35CxD
Model RDCS20T RDCS25T RDCS35T RDCS20C RDCS25C RDCS35C
A (mm)
3-1/8˝ (79.38) 3-19/64˝ (83.74) 4-11/32˝ (110.33) 4-9/64˝ (105.17) 4-7/16˝ (112.71) 5-23/64˝ (136.13)
A (mm)
3-1/8˝ (79.38) 3-19/64˝ (83.74) 4-11/32˝ (110.33) 4-9/64˝ (105.17) 4-7/16˝ (112.71) 5-23/64˝ (136.13)
B (mm)
2-47/64˝ (69.45) 3-7/32˝ (81.76) 3-43/64˝ (93.27) 3-25/64˝ (86.10) 4-43/64˝ (118.67) 5-21/64˝ (135.33)
B (mm)
2-47/64˝ (69.45) 3-7/32˝ (81.76) 3-43/64˝ (93.27) 3-25/64˝ (86.1) 4-43/64˝ (118.67) 5-21/64˝ (135.33)
C (mm)
2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9) 2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9)
C (mm)
2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9) 2-45/64˝ (68.66) 2-53/64˝ (71.83) 3-1/2˝ (88.9)
D (mm)
1-37/64˝ (40.08) 1-55/64˝ (47.23) 2-17/32˝ (64.29) 2-39/64˝ (66.28) 3˝ (76.20) 3-35/64˝ (90.09)
D (mm)
1-37/64˝ (40.08) 1-55/64˝ (47.23) 2-17/32˝ (64.29) 2-39/64˝ (66.28) 3˝ (76.20) 3-35/64˝ (90.09)
E (mm)
1-15/64˝ (31.35) 1-31/64˝ (37.70) 1-15/32˝ (37.31) 1-51/64˝ (45.64) 2-49/64˝ (70.25) 2-61/64˝ (75.01)
E (mm)
1-15/64˝ (31.35) 1-31/64˝ (37.70) 1-15/32˝ (37.31) 1-51/64˝ (45.64) 2-49/64˝ (70.25) 2-61/64˝ (75.01)
F (mm)
2-5/32˝ (54.77) 2-11/32˝ (59.53) 2-3/8˝ (60.33) 2-11/64˝ (55.17) 2-23/64˝ (59.93) 2-3/8˝ (60.33)
Diaphragm Pulse
Valves,
Figure 1: Closed Position
Figure 2: Open Position
503