Dwyer Instruments SERIES P5 Catalog Page

Series
3-13-16
[96.84]
OR 4-3/8
[111.13]
W/ 1/2 NPT
PORT ADAPTER
A 2 PLACES
B
1-1/2 [38.1] OR 2-1/16 [52.39] W/ 1/2 NPT PORT ADAPTER
ø1-5/8
[ø41.28]
P5
PVC Shuttle Flow Switch
Low Cost Flow/No Flow Monitoring, Visual Flow Indication, Broad Chemical Compatibility
DIM “A”
1/2 NPT
3/4 IPS
1 IPS
DIM “B”
(2-5/16) [58.74] (2-1/16) [52.39] (1-15/16) [49.21]
The transparent Series P5 Shuttle Flow Switch features corrosion resistant, durable PVC housing for visual confirmation in flow/no flow applications. The switches have preset actuation points from 0.5 to 2.0 GPM for actuation on increasing flow. Switching is SPST NO no flow. Choose from 1/2˝ NPT or 3/4˝ IPS (for 0.5 GPM) or 1˝ IPS (for 2.0 GPM) inlet and outlet ports. The shuttle design has only one moving part for long life and minimum maintenance. Remove the one-piece bonnet and shuttle assembly to quickly clean the unit without disturbing the housing or piping. Rugged construction and excellent chemical compatibility simplify flow / no flow detection.
Actuation Set Point Model P5-1 P5-2 P5-3
GPM (LPM)
.5 (1.89)
.5 (1.89)
2.0 (7.57)
Process Connection
1/2˝ NPT port adapter 3/4˝ IPS 1˝ IPS
SPECIFICATIONS Service: Compatible liquids. Wetted Materials: Housing, shuttle and bonnet: PVC; O-ring: Buna-N; Epoxy. Temperature Limits: 120°F (49°C). Pressure Limit: 120 psig (8.2 bar) @ 70°F (21°C) to 100°F (38°C), 50 psig (3.45
bar) @ 101°F (38.3°C) to 120°F (49°C).
Accuracy: ±20% of set point. Repeatability: ±1%. Switch Type: SPST, NO. Electrical Rating:
VDC.
Electrical Connection: 22 AWG, 24˝ (61 cm), PVC lead wire. Process Connection: 1/2˝ female NPT, 3/4˝ IPS or 1˝ IPS. Required Filtration: 150 microns or better. Mounting Orientation: Vertical, inlet facing down. Weight: 6 oz (.17 kg). Agency Approvals: CE.
.17A @ 120 VAC, .08A @ 240 VAC, .13A @ 120 VDC, .06A @ 240
FLOW