Dwyer Instruments SERIES MTF Catalog Page

Series
[H]
[A]
[W]
1/2 [12.70]
[O]
1
/8 FEMALE NPT
9/16-18
[14.29]
35/64
[13.97]
1-27/32
[46.99] OPEN
1-1/8
[28.70]
M
Multitube Flow Systems
TF
Customize to Fit Application, 65 mm or 150 mm Variable Area Flow Tubes
ustomize flow systems to meet application requirements. Systems can be
onfigured with up to six different flow tubes with various flow capacities and flow
c
atterns. The Series MTF Multitube Flow Systems are ideal for multichannel
p metering, mixing, or monitoring applications.
FLOW
To customize your flow system:
1) Determine the flow pattern required for the application (see below).
2) Select a 65 mm or 150 mm frame (next page), along with the appropriate number of tubes required, flow pattern, and wetted parts. Choose a 150 mm Gas Proportioner Frame (Series MTP) to blend 2 or 3 gases at required concentrations. Gas proportioner frames are typically used at 50 psi.
3) Choose the appropriate 65 mm or 150 mm correlated flow tubes (next page), for air or water.
4) Select a valve cartridge if desired that matches the range of the flow tube (next page).
Isolated parallel channels
Flowmeters, Variable Area
Dimensions
3 tubes
3-1/4 [82.55] 3-1/4 [82.55]
DIM “W”
4 tubes
4-1/4 [107.95] 4-1/4 [107.95]
5 tubes
5-1/4 [133.35] 5-1/4 [133.35]
6 tubes
6-1/4 [158.75] 6-1/4 [158.75]
DIM “A” Scale Length
65 mm
150 mm
SPECIFICATIONS Scales: Universal 65 mm or 150 mm scales with correlation charts. Accuracy: ±2% FS @ 70°F (21.1°C) and 14.7 psia (1 atm absolute). Repeatability: ±0.25% of scale reading. Turn-down Ratio: 10:1, 20:1 with combinations of two floats installed in meter. Maximum Operating Pressure: 200 psig (13.8 bar). Maximum Operating Temperature: 250°F (121°C). Mounting: Vertical. Connection: 1/8˝ female NPT. Flowtube: Borosilicate glass. Float: 316 SS or black glass as indicated. Float Stops: PTFE. End Fittings: Anodized aluminum or 316 SS. Front Shield: Polycarbonate. Side Panels: Black, anodized aluminum. O-rings: Buna-N on aluminum models and fluoroelastomer on stainless steel models.
DIM “H”
5-1/2 [139.70] 9-13/16 [249.25]
DIM “O”
4-1/2 [114.30] 8-13/16 [223.85]
1 tube
1-1/4 [31.75] 1-1/4 [31.75]
2 tubes
2-1/4 [57.15] 2-1/4 [57.15]
Common exhaust with parallel inlets
Common inlet with parallel exhausts
USA: California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
5 mm Frames
6
etted Parts
odel
M
TF-1621
M
TF-2621
M MTF-1622 MTF-2622 MTF-1631
TF-2631
M
TF-1632
M
TF-2632
M
TF-1641
M MTF-2641 MTF-1642 MTF-2642
TF-1651
M
TF-2651
M
TF-1652
M MTF-2652 MTF-1661 MTF-2661 MTF-1662
TF-2662
M
attern
P
solated
I
solated
I Common Common Isolated
solated
I
ommon
ommon
solated
I Isolated Common Common
solated
I
solated
I
ommon
ommon
ube Capacity
T
2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6
W
luminum
A
16 SS
3 Aluminum 316 SS Aluminum
16 SS
3
luminum
A
16 SS
3
luminum
A 316 SS Aluminum 316 SS
luminum
A
16 SS
3
luminum
A 316 SS Aluminum 316 SS Aluminum
16 SS
3
*Flow rates are given for standard pressure and
emperature 70°F (21°C) @ 760 mm Hg.
t
5 mm Direct Reading Flow Tubes
6
ax. Flow Rate Air
M
odel
M F F FT-746 FT-748 FT-750 F F F
T-741 T-743
T-752 T-753 T-754
60 SCFM
.
.2 SCFH
2
6.0 SCFH
10.0 SCFH
18.0 SCFH
5.0 SCFH
2
0.0 SCFH
5
0.0 SCFH
9
65 mm Correlated Flow Tubes
Max. Flow Rate (mL/min)*
Model
T-61
F
T-62
F
T-63
F FT-64 FT-67 FT-68 FT-611
T-612
F
T-613
F
T-614
F FT-617 FT-618
T-621
F
T-622
F
Air
6
7
1
9
4 145 202 522 1249
520
2
040
2
990
3 6318 12058
3169
2
2094
4
Water
.07
0
.28
0
.55
0
2.38
2.60
12.0 27
1
7
0
4
08
1 147 364
22
5
261
1
loat
F
arboloy
lass
G Glass 316 SS 316 SS
16 SS
3
16 SS
3
16 SS
3
Float
G 3 G 316 SS Glass 316 SS Glass 3 G 3 Glass 316 SS G 3
lass
16 SS
lass
16 SS
lass
16 SS
lass
16 SS
150 mm Frames
etted Parts
odel
M MTF-1121 MTF-2121 MTF-1122 MTF-2122 MTF-1131 MTF-2131 MTF-1132 MTF-2132 MTF-1141 MTF-2141 MTF-1142 MTF-2142 MTF-1151 MTF-2151 MTF-1152 MTF-2152 MTF-1161 MTF-2161 MTF-1162 MTF-2162
attern
P
Isolated Isolated Common Common Isolated Isolated Common Common Isolated Isolated Common Common Isolated Isolated Common Common Isolated Isolated Common Common
ube Capacity
T
2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6
W
Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS Aluminum 316 SS
150 mm Gas Proportioner Frames
Model MTP-112 MTP-212 MTP-113 MTP-213
Tube Capacity
2 2 3 3
Wetted Parts
Aluminum 316 SS Aluminum 316 SS
Valve Cartridges
For metering or mixing applications, complete your multitube flow system by selecting a valve cartridge suitable for the flow range. Choose a standard 6-turn valve or high precision 16-turn valve.
SPECIFICATIONS Wetted Parts 6-turn Valves: For Aluminum frames: Aluminum body, 316 SS
spindle, Acetal orifice, Buna-N O-rings; for 316 SS frames: 316 SS body, 316 SS spindle, PCTFE orifice, Fluoroelastomer O-rings.
Wetted Parts 16-turn Valves: For Aluminum frames: Brass body, 316 SS spindle, PCTFE orifice, Buna-N O-rings; for 316 SS frames: 316 SS body, 316 SS spindle, PCTFE orifice, Fluoroelastomer O-rings.
150 mm Direct Reading Flow Tubes
loat
odel
M FT-242 FT-244 FT-245 FT-247 FT-248 FT-249 FT-251 FT-253 FT-254 FT-255
ax. Flow Rate Air
M
1.50 SCFM
2.50 SCFH
5.00 SCFH
8.25 SCFH
10.0 SCFH
16.5 SCFH
23.0 SCFH
50.0 SCFH
90.0 SCFH
94.0 SCFH
F
316 SS Carboloy Glass Glass 316 SS 316 SS Carboloy Glass 316 SS 316 SS
150 mm Correlated Flow Tubes
Max. Flow Rate (mL/min)* Model FT-123 FT-124 FT-125 FT-126 FT-127 FT-128 FT-129 FT-130 FT-133 FT-134 FT-137 FT-138 FT-139
Air
19
61
49
137
92
264
374
814
2313
4562
8678
16737
22536
Water
0.19
0.94
0.53
2.45
0.90
4.70
5.50
20.4 54 130 210 506 541
Float
Glass 316 SS Glass 316 SS Glass 316 SS Glass 316 SS Glass 316 SS Glass 316 SS Glass
Model Standard Valve 6-turn
Aluminum FV-11 FV-12 FV-13
SS FV-21 FV-22 FV-23
Flow Rate (Air) mL/min
0 to 5000 5001 to 10000 10001 and above
Flow Rate (H mL/min
0 to 125 126 to 325 326 and above
2O)
Model High Precision Valve 16-turn
Aluminum FVH-11 FVH-12 FVH-13 FVH-14 FVH-15 FVH-16
SS VA81 VA82 VA83 VA84 VA85 VA86
Flow Rate (Air) mL/min
0 to 200 201 to 400 401 to 1000 1001 to 2500 2501 to 6200 6201 and above
Flow Rate (H mL/min
0 to 6 7 to 12 13 to 26 27 to 80 81 to 200 201 and above
2O)
USA: California Proposition 65 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
FLOW
Flowmeters, Variable Area
Loading...