SERIES LTI
TEMPERATURE PANEL METER
1/8 DIN TC and RTD Dual Line Display
TEMPERATURE
[45.0]
4-49/64
[121.0]
5-3/64 [128.0]
25/64 [10.0]
3-5/8 [92.0]
4-1
The Series LTI Temperature Panel Meter can be programmed in the eld to accept a thermocouple or RTD input and display the temperature on a six-digit dual line display. The upper display will display four digits of temperature as well as °C or °F symbol. The lower display can be programmed to contain a tag. The Series LTI meters feature a NEMA 4X / IP65 front panel making them ideal for wet, dusty and dirty environments. Options include 2 or 4 relays and a 4-20 mA output. The 4-20 mA output option turns the LTI into an isolated temperature transmitter with a digital display. The LTI includes free USB based programming software to make programming a breeze.
FEATURES/BENEFITS
• J, K, T, E, R, S, B, N, C thermocouples
• 100 or 1000 Ω platinum, 10 Ω copper, 120 Ω nickel RTDs
• Automatic cold junction compensation
• NEMA 4X, IP65 front
• 2 or 4 relays + isolated 4-20 mA output options
APPLICATIONS
• Temperature metering and monitoring
MODEL CHART Model Description LTI-100
Panel Meters/Indicators
LTI-101 LTI-120 LTI-121 LTI-140 LTI-141 LTI-200 LTI-201 LTI-220 LTI-221 LTI-240 LTI-241
85-265 VAC, no relays, no transmitter 85-265 VAC, no relays, 4-20 mA transmitter 85-265 VAC, 2 relays, no transmitter 85-265 VAC, 2 relays, 4-20 mA transmitter 85-265 VAC, 4 relays, no transmitter 85-265 VAC, 4 relays, no transmitter 12-24 VAC, no relays, no transmitter 12-24 VAC, no relays, 4-20 mA transmitter 12-24 VAC, 2 relays, no transmitter 12-24 VAC, 2 relays, 4-20 mA transmitter 12-24 VAC, 4 relays, no transmitter 12-24 VAC, 4 relays, 4-20 mA transmitter
SPECIFICATIONS Inputs: Thermocouple J, K, T, E, R, S, B, N, C; RTD 100 Ω platinum, 10 Ω copper,
120 Ω nickel, 1000 Ω platinum.
Input Impedance: Greater than 100 k Ω. Output signal (option): Isolated 4-20 mA. Power Requirements: 85-265 VAC 50/60 Hz, 90-265 VDC or jumper selectable
12-24 VDC ±10%.
Power Consumption: 90-265 VAC models: 20 W max; 12-24 VDC models: 15 W
max.
Switch Rating (option): 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A)
external; Rated 3A @ 30 VDC and 125/250 VAC resistive load, 1/14 HP @ 125/250 VAC for inductive loads.
Display: Dual-line, 6-digit display. Resolution: 1° (up to four digits) or 0.1° (up to ve digits). Temperature Limits: Operating: -4 to 149°F (-20 to 65°C); Storage: -40 to 185°F (-40 to 85°C). Humidity limits: 0 to 90% (non-condensing).
Front Panel Rating: NEMA 4X, IP65. Weight: 9.5 oz (269 g). Agency Approvals: CE, RoHS, cUL, UL. Programming Software: Free, USB based. Resident on meter, nothing to
download.
INPUT RANGE AND ACCURACY Type Range (°F) Range (°C) Accuracy Type Range (°F) Range (°C) Accuracy J K T E R S B
-200 to 2000
-200 to 2400
-200 to 752
-200 to 1800
-50 to 3000
-50 to 3000 752 to 3300
-129 to 1093
-129 to 1316
-129 to 400
-129 to 982
-46 to 1649
-46 to 1649
-400 to 1816
±1°C ±1°C ±1°C ±1°C ±2°C ±2°C ±2°C
J C
10 Ω 100 Ω 120 Ω 1000 Ω
-100 to 2300 32 to 4100
-328 to 500
-328 to 1562
-110 to 500
-328 to 900
-73 to 1260 0 to 2260
-200 to 260
-200 to 850
-79 to 260
-200 to 482
±2°C ±2°C ±0.1°C ±0.4°C ±0.1°C ±0.4°C