SERIES ISDP
INTRINSICALLY SAFE DIFFERENTIAL PRESSURE TRANSMITTER
For Hazardous Zone Pressure and Flow Applications
[21.18]
[75.39]
1-15/16
[48.97]
4-9/64 [105.17]
4-23/32
[120]
5-7/32
[132.54]
3-7/16
[87.12]
BRACKETS
ARE OPTIONA
PRESSURE
Shown with optional A-438 mounting bracket
1-5/32
[29.59]
The Series ISDP Intrinsically Safe Differential Pressure Transmitter provides a
4-20 mA process output, a robust NEMA 4X enclosure, plus a large LCD display that
can be programmed to read in pressure, velocity or ow. The ISDP offers simplied
programming via a Menu key that enables the user to select: security level; English
or Metric engineering units; pressure, velocity or ow operation, K-factor for use with
various Pitot tubes and ow sensors, circular or rectangular duct size for volumetric
ow operation plus many more. The Series ISDP Differential Pressure Transmitter
is powered on its two wire loop with 10-35 VDC via its integral M-12 four pin male
connector. The ISDP provides a 0.5% full-scale accuracy on ranges from 0.25 in w.c.
to 100 in w.c. as well as bi-directional models up to 10 in w.c. These features make
the Series ISDP Differential Pressure Transmitter the ideal instrument for monitoring
pressures or air ows in hazardous zones having a Class I Div. I Groups A, B, C, D;
Class II Div. I Groups E, F, G; Class III Div. I ratings.
FEATURES/BENEFITS
• NEMA 4X rated enclosure provides protection in harsh environments permitting
outdoor monitoring or in areas where dust and particulate matter exists
• Easy to read LCD display provides immediate local alerts allowing corrective action
to be taken quicker to eliminate the problem from becoming widespread
• Intrinsically safe for use in the specied hazardous locations meets specications
where pressure transmission and safety cannot be compromised
• Password protected set up menu helps to insure no errors by untrained personnel
when accessing the powerful measurement capabilities of this device
APPLICATIONS
• Hazardous zone pressure control applications
• Hazardous ow and control applications
MODEL CHART
Model Range (in w.c.) Model Range (in w.c.)
ISDP-002
ISDP-004
ISDP-006
ISDP-007
ISDP-008
ISDP-009
ISDP-010
OPTIONS
To order add sufx: Description
-NIST NIST traceable calibration certicate
Example: ISDP-004-NIST
-FC Factory calibration certicate
Example: ISDP-004-FC
0 to 0.25
0 to 1
0 to 5
0 to 10
0 to 25
0 to 50
0 to 100
ISDP-012
ISDP-014
ISDP-015
ISDP-016
ISDP-017
0 to ±0.25
0 to ±1.0
0 to ±2.5
0 to ±5.0
0 to ±10
1-5/16
[33]
SPECIFICATIONS
Service: Air and non-combustible gases.
Wetted Materials: Ranges 5 in w.c. and greater: glass, PVC, silicon, alumina
ceramic, epoxy, RTV, gold, aluminum, stainless steel and nickel; Ranges 1 in w.c.
and lower: stainless steel, silicone, gold and ceramic.
Housing Materials: Aluminum, glass.
Accuracy: ±0.5% at 77°F (25°C) including hysteresis and repeatability (after 1 hour
warm-up).
Stability: < ±1% per year.
Pressure Limits: Ranges ≤ 2.5 in w.c. = 2 psi; 5 in w.c.: 5 psi; 10 in w.c.: 5 psi;
25 in w.c.: 5 psi; 50 in w.c.: 5 psi; 100 in w.c.: 9 psi.
Temperature Limits: 32 to 140°F (0 to 60°C).
Compensated Temperature Limits: 32 to 140°F (0 to 60°C).
Thermal Effects: 0.020%/°F (0.036/°C) from 77°F (25°C).
Power Requirements: 10-35 VDC.
Output Signal: 4-20 mA DC.
Zero and Span Adjustments: Accessible via menus.
Response Time: 250 ms (damping set to 1).
Display: 4 digit LCD 0.6˝ H.
Electrical Connections: M-12 4 PIN Connector.
Process Connections: 1/8˝ female NPT.
Enclosure Rating: Designed to meet NEMA 4X (IP66).
Mounting Orientation: Mount unit in vertical plane.
Weight: 2 lb 10 oz (1.19 kg).
Agency Approvals: CE: CENELEC EN 61326/55024: 2003; IEC 61000-4-2/3/4/6:
2001/2006/2004/2005; CENELEC EN 55011: 2006; 2004/108/EC EMC Directive.
FM Intrinsically Safe CLI Div I GR: A, B, C, D; CLII Div I GR: E, F, G; CLIII Div I.
ACCESSORIES
Model Description
A-231
A-486
A-487
A-488
A-295
MTL5541
MTL7706
A-438
1-17/32
[38.61]
16´ (5 m) shielded cable with 4 pin female M-12 connection
4.9´ (1 m) shielded cable with 4 pin female M-12 connection
9.8´ (3 m) shielded cable with 4 pin female M-12 connection
33´ (10 m) shielded cable with 4 pin female M-12 connection
Female 4 pin M-12 to cable gland connector
Intrinsically safe galvanic isolator
Intrinsically safe zener barrier
Surface mounting brackets
Process Tubing Options: See page 453 (Gage Tubing Accessories)
45/64
[17.78]
MOUNTING HOLE
PATTERN
4-1/8
[105]
1-45/64
[43.18]
4X ø3/16 [4.76]
CLEARANCE
HOLES FOR
MOUNTING
3-17/64
[83]
DWYER INSTRUMENTS, INC.
Differential Pressure Transmitters,
Air & Gas
69