SERIES HM28
PRECISION HANDHELD DIGITAL MANOMETER
High Accuracy (0.2%, 0.1% or 0.05%), Differential, Gage or Absolute
Portable
Manometers,
3-1/4 [82.55]
5-61/64
[151.21]
1-5/16
[33.34]
The Series HM28 Precision Handheld Digital Manometer is designed to measure
a wide range of pressures with up to 0.05% accuracy. The data logging function can
store up to 964 readings and transmit the readings to a PC through an IR serial report.
The dual line LCD is able to display a resolution to 0.001 of the selected unit and
indicate peaks and valleys.
FEATURES/BENEFITS
• Measures differential, gage, or absolute pressure
• Able to record up to 964 readings, which can be downloaded to a PC
• Up to 0.05% accuracy
APPLICATIONS
• Calibration facilities
• Laboratories
MODEL CHART
Model Features
Error limit 0.2% FS for gage, underpressure and differential pressure
HM28D3B10000
HM28D3C10000
HM28D3F10000
Error limit 0.05% FS for gage, underpressure and differential pressure
HM28D3C30000
HM28D3F30000
HM28D3K30000
For absolute pressure
HM28A3I10000 0 to 15.9 psia (0.2% FS (110 kPa abs))
Note: Consult factory for 0.10% models.
0 to 10 in w.c. (2.5 kPa)
0 to 28 in w.c. (7 kPa)
0 to 120 in w.c. (30 kPa)
0 to 28 in w.c. (7 kPa)
0 to 120 in w.c. (30 kPa)
0 to 100 psi (700 kPa)
ACCESSORIES
Model Description
HM28-0
HM28-1
HM28-2
DWYER INSTRUMENTS, INC. 176
SPECIFICATIONS
Service: Air and compatible gases.
Accuracy: (Includes linearity, hysteresis,
and repeatability): per order code.
±0.20% FS ±1 digit; ±0.10% FS ±1 digit;
±0.05% FS ±1 digit.
Wetted Materials: 18/8 stainless steel.
Temperature Limits: 23 to 122°F (-5 to
50°C).
Storage Temperature: -4 to 140°F (-20
to 60°C).
Humidity: 30 to 95% rH, noncondensing.
Display: 2 line, 16 character, dot matrix
LCD, with switchable display sizes.
Power Requirements: 9 V alkaline
battery, installed functional, user
replaceable. Can operate from external
power supply of 7-14 VDC.
1/8˝ NPT adapter (1 piece)
Communication software
and cable
Universal power adapter
OPTIONS
Use order code: Description
NISTCAL-MD1 NIST traceable calibration certicate
Current Consumption: < 9 mA.
Memory: 964 measured values.
Recording intervals adjustable from
manual, 1, 5, 10, 20, 30 s, 1, 2, 3, 5, 10,
30, 60 minutes.
Case Protection: IP54 (NEMA 3).
Case Dimensions: 6˝ x 3.27˝ x 1.34˝
(152 x 83 x 34 mm).
Weight: 9.5 oz (270 g).
Process Connections: Hose; 4/6 mm
or 1/8˝ NPT.
Maximum Measurement Rates: Stand
alone: 2-1/2 readings/s (0.1% and 0.05%
ratings), 5 readings/s (0.2% rating).
Output to RS-232: 20 measurements/s
(0.2% rating). 10 measurements/s (0.1%
and 0.05% ratings).
RS-232 Baud Rate: Adjustable, 1200,
2400, 4800, or 9600 baud.